These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 25655957)

  • 1. The biochemical characteristics of wear testing lubricants affect polyethylene wear in orthopaedic pin-on-disc testing.
    Guenther LE; Turgeon TR; Bohm ER; Brandt JM
    Proc Inst Mech Eng H; 2015 Jan; 229(1):77-90. PubMed ID: 25655957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear testing of crosslinked polyethylene: wear rate variability and microbial contamination.
    Brandt JM; Vecherya A; Guenther LE; Koval SF; Petrak MJ; Bohm ER; Wyss UP
    J Mech Behav Biomed Mater; 2014 Jun; 34():208-16. PubMed ID: 24607759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials.
    Scholes SC; Joyce TJ
    Proc Inst Mech Eng H; 2013 Jun; 227(6):693-703. PubMed ID: 23636752
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influences of dehydration and rehydration on the lubrication properties of phospholipid polymer-grafted cross-linked polyethylene.
    Yarimitsu S; Moro T; Kyomoto M; Watanabe K; Tanaka S; Ishihara K; Murakami T
    Proc Inst Mech Eng H; 2015 Jul; 229(7):506-14. PubMed ID: 26036469
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative wear tests of ultra-high molecular weight polyethylene and cross-linked polyethylene.
    Harsha AP; Joyce TJ
    Proc Inst Mech Eng H; 2013 May; 227(5):600-8. PubMed ID: 23637270
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant.
    DesJardins J; Aurora A; Tanner SL; Pace TB; Acampora KB; Laberge M
    Proc Inst Mech Eng H; 2006 Jul; 220(5):609-23. PubMed ID: 16898218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricant.
    Hyde PJ; Fisher J; Hall RM
    Proc Inst Mech Eng H; 2016 May; 230(5):481-8. PubMed ID: 27160565
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?
    Kandemir G; Smith S; Chen J; Joyce TJ
    J Mech Behav Biomed Mater; 2020 Dec; 112():104067. PubMed ID: 32905920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of lubricants on friction in laboratory tests of a total disc replacement device.
    Moghadas P; Mahomed A; Hukins DW; Shepherd DE
    Proc Inst Mech Eng H; 2013 Sep; 227(9):988-93. PubMed ID: 23804950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?
    Reinders J; Sonntag R; Kretzer JP
    J Mater Sci Mater Med; 2014 Nov; 25(11):2463-9. PubMed ID: 25015325
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing.
    Brandt JM; Charron K; Zhao L; MacDonald SJ; Medley JB
    Proc Inst Mech Eng H; 2012 Jun; 226(6):427-40. PubMed ID: 22783759
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear studies on prosthetic materials using the pin-on-disc machine.
    Wright KW; Dobbs HS; Scales JT
    Biomaterials; 1982 Jan; 3(1):41-8. PubMed ID: 7066466
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing.
    Brandt JM; Brière LK; Marr J; MacDonald SJ; Bourne RB; Medley JB
    J Biomed Mater Res A; 2010 Sep; 94(3):961-71. PubMed ID: 20730933
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental friction coefficients for bovine cartilage measured with a pin-on-disk tribometer: testing configuration and lubricant effects.
    Shi L; Sikavitsas VI; Striolo A
    Ann Biomed Eng; 2011 Jan; 39(1):132-46. PubMed ID: 20872073
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: an in vitro experimental model.
    Greenbaum ES; Burroughs BB; Harris WH; Muratoglu OK
    Biomaterials; 2004 Aug; 25(18):4479-84. PubMed ID: 15046938
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Challenges associated with using bovine serum in wear testing orthopaedic biopolymers.
    Harsha AP; Joyce TJ
    Proc Inst Mech Eng H; 2011 Oct; 225(10):948-58. PubMed ID: 22204117
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine.
    Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2007 Apr; 221(3):281-9. PubMed ID: 17539583
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles.
    Moro T; Kyomoto M; Ishihara K; Saiga K; Hashimoto M; Tanaka S; Ito H; Tanaka T; Oshima H; Kawaguchi H; Takatori Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():100-6. PubMed ID: 23651567
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear of PEEK-OPTIMA® and PEEK-OPTIMA®-Wear Performance articulating against highly cross-linked polyethylene.
    East RH; Briscoe A; Unsworth A
    Proc Inst Mech Eng H; 2015 Mar; 229(3):187-93. PubMed ID: 25833994
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy.
    Kumar P; Oka M; Ikeuchi K; Shimizu K; Yamamuro T; Okumura H; Kotoura Y
    J Biomed Mater Res; 1991 Jul; 25(7):813-28. PubMed ID: 1918102
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.