These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 25657198)

  • 1. Prolonged duration of transbrachial intra-aortic balloon pump as bridge to heart transplantation.
    Smith TB; Shridhar P; Khalil R; Lasorda DM
    BMJ Case Rep; 2015 Feb; 2015():. PubMed ID: 25657198
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intra-aortic balloon pump inserted through the subclavian artery: A minimally invasive approach to mechanical support in the ambulatory end-stage heart failure patient.
    Russo MJ; Jeevanandam V; Stepney J; Merlo A; Johnson EM; Malyala R; Raman J
    J Thorac Cardiovasc Surg; 2012 Oct; 144(4):951-5. PubMed ID: 22520721
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous placement of an intra-aortic balloon pump in the left axillary/subclavian position provides safe, ambulatory long-term support as bridge to heart transplantation.
    Estep JD; Cordero-Reyes AM; Bhimaraj A; Trachtenberg B; Khalil N; Loebe M; Bruckner B; Orrego CM; Bismuth J; Kleiman NS; Torre-Amione G
    JACC Heart Fail; 2013 Oct; 1(5):382-8. PubMed ID: 24621970
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transbrachial insertion of a 7.5-Fr intra-aortic balloon pump in a severely atherosclerotic patient.
    Onorati F; Bilotta M; Pezzo F; Impiombato B; Caroleo S; Santangelo E; Renzulli A
    Crit Care Med; 2006 Aug; 34(8):2231-3. PubMed ID: 16775570
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist device.
    Norkiene I; Ringaitiene D; Rucinskas K; Samalavicius R; Baublys A; Miniauskas S; Sirvydis V
    Interact Cardiovasc Thorac Surg; 2007 Feb; 6(1):66-70. PubMed ID: 17669772
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intra-Aortic Balloon Counterpulsation in Patients With Chronic Heart Failure and Cardiogenic Shock: Clinical Response and Predictors of Stabilization.
    Sintek MA; Gdowski M; Lindman BR; Nassif M; Lavine KJ; Novak E; Bach RG; Silvestry SC; Mann DL; Joseph SM
    J Card Fail; 2015 Nov; 21(11):868-76. PubMed ID: 26164215
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of Intra-aortic Balloon Pump as a Bridge to Heart Transplant in Spain: Results From the ASIS-TC Study.
    Barge-Caballero E; González-Vílchez F; Delgado JF; Mirabet-Pérez S; González-Costello J; Pérez-Villa F; Martínez-Sellés M; Segovia-Cubero J; Hervás-Sotomayor D; Blasco-Peiró T; De la Fuente-Galán L; Lambert-Rodríguez JL; Rangel-Sousa D; Almenar-Bonet L; Garrido-Bravo IP; Rábago-Juan-Aracil G; Muñiz J; Crespo-Leiro MG
    Rev Esp Cardiol (Engl Ed); 2019 Oct; 72(10):835-843. PubMed ID: 30115570
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Migration of Intraaortic Balloon Pump Placed Via the Axillary Artery.
    Barac YD; Alwair H; Kong DF; Patel CB; Daneshmand MA; Milano CA; Schroder JN
    J Invasive Cardiol; 2018 Jan; 30(1):E11. PubMed ID: 29289953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation.
    Idelchik GM; Simpson L; Civitello AB; Loyalka P; Gregoric ID; Delgado R; Kar B
    J Heart Lung Transplant; 2008 Jan; 27(1):106-11. PubMed ID: 18187095
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Support with intra-aortic balloon pump vs. Impella2.5® and blood flow to the heart, brain and kidneys - an experimental porcine model of ischaemic heart failure.
    Møller-Helgestad OK; Poulsen CB; Christiansen EH; Lassen JF; Ravn HB
    Int J Cardiol; 2015 Jan; 178():153-8. PubMed ID: 25464241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant.
    Umakanthan R; Hoff SJ; Solenkova N; Wigger MA; Keebler ME; Lenneman A; Leacche M; Disalvo TG; Ooi H; Naftilan AJ; Byrne JG; Ahmad RM
    J Thorac Cardiovasc Surg; 2012 May; 143(5):1193-7. PubMed ID: 22365064
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?
    Sabashnikov A; Popov AF; Bowles CT; Mohite PN; Weymann A; Hards R; Hedger M; Wittwer T; Wippermann J; Wahlers T; Schoendube FA; Simon AR
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):1115-21; discussion 1021-2. PubMed ID: 25129605
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of prophylactic intra-aortic balloon pump therapy in chronic heart failure patients undergoing cardiac surgery.
    Yildirim Y; Pecha S; Kubik M; Alassar Y; Deuse T; Hakmi S; Reichenspurner H
    Artif Organs; 2014 Nov; 38(11):967-72. PubMed ID: 24571119
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ambulatory intraaortic balloon pump use as bridge to heart transplant.
    Cochran RP; Starkey TD; Panos AL; Kunzelman KS
    Ann Thorac Surg; 2002 Sep; 74(3):746-51; discussion 751-2. PubMed ID: 12238834
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Supported percutaneous coronary intervention using a novel 6-Fr intra-aortic balloon pump catheter via the brachial artery in a nonagenarian patient with an abdominal aortic aneurysm.
    Takahashi A; Taniguchi N
    Catheter Cardiovasc Interv; 2011 Jun; 77(7):1045-8. PubMed ID: 21413123
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intra-Aortic Balloon Pump Catheter Insertion Using a Novel Left External Iliac Artery Approach in A Case of Chronic Heart Failure Due to Dilated Cardiomyopathy.
    Dziekiewicz M; Banaszewski M; Kuć M; Stępińska J
    Am J Case Rep; 2019 Dec; 20():1826-1829. PubMed ID: 31811112
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transaxillary Intra-Aortic Balloon Pump Migration Minimized With a Long Introducer Sheath.
    Dorsey A; Karimianpour A; Fernandes VL
    Cardiovasc Revasc Med; 2021 Sep; 30():85-88. PubMed ID: 33082080
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction.
    Seyfarth M; Sibbing D; Bauer I; Fröhlich G; Bott-Flügel L; Byrne R; Dirschinger J; Kastrati A; Schömig A
    J Am Coll Cardiol; 2008 Nov; 52(19):1584-8. PubMed ID: 19007597
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility of 6 Fr intra-aortic balloon pumping via the femoral or brachial approach.
    Fujii T; Masuda N; Ijichi T; Kamiyama Y; Tanaka S; Nakazawa G; Shinozaki N; Matsukage T; Ogata N; Ikari Y
    J Invasive Cardiol; 2012 Dec; 24(12):641-4. PubMed ID: 23220978
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous Left Axillary Artery Placement of Intra-Aortic Balloon Pump in Advanced Heart Failure Patients.
    Bhimaraj A; Agrawal T; Duran A; Tamimi O; Amione-Guerra J; Trachtenberg B; Guha A; Hussain I; Kim J; Kassi M; Xu J; Suarez E; Ngo UQ; Torre-Amione G; Estep JD
    JACC Heart Fail; 2020 Apr; 8(4):313-323. PubMed ID: 32241538
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.