BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

291 related articles for article (PubMed ID: 25659233)

  • 21. EEG noise cancellation by a subspace method based on wavelet decomposition.
    Olkkonen H; Pesola P; Olkkonen J; Valjakka A; Tuomisto L
    Med Sci Monit; 2002 Nov; 8(11):MT199-204. PubMed ID: 12444387
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparative study of single-channel signal processing methods in fetal phonocardiography.
    Barnova K; Kahankova R; Jaros R; Litschmannova M; Martinek R
    PLoS One; 2022; 17(8):e0269884. PubMed ID: 35984866
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Seismic Random Noise Denoising Using Mini-Batch Multivariate Variational Mode Decomposition.
    Wu G; Liu G; Wang J; Fan P
    Comput Intell Neurosci; 2022; 2022():2132732. PubMed ID: 35256873
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Combination of canonical correlation analysis and empirical mode decomposition applied to denoising the labor electrohysterogram.
    Hassan M; Boudaoud S; Terrien J; Karlsson B; Marque C
    IEEE Trans Biomed Eng; 2011 Sep; 58(9):2441-7. PubMed ID: 21558055
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An integrated EMD adaptive threshold denoising method for reduction of noise in ECG.
    Zhang M; Wei G
    PLoS One; 2020; 15(7):e0235330. PubMed ID: 32667934
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Automatic identification and removal of ocular artifacts in EEG--improved adaptive predictor filtering for portable applications.
    Zhao Q; Hu B; Shi Y; Li Y; Moore P; Sun M; Peng H
    IEEE Trans Nanobioscience; 2014 Jun; 13(2):109-17. PubMed ID: 24802943
    [TBL] [Abstract][Full Text] [Related]  

  • 27. EEG artifacts reduction by multivariate empirical mode decomposition and multiscale entropy for monitoring depth of anaesthesia during surgery.
    Liu Q; Chen YF; Fan SZ; Abbod MF; Shieh JS
    Med Biol Eng Comput; 2017 Aug; 55(8):1435-1450. PubMed ID: 27995430
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Improved Vancouver Raman Algorithm Based on Empirical Mode Decomposition for Denoising Biological Samples.
    León-Bejarano F; Méndez MO; Ramírez-Elías MG; Alba A
    Appl Spectrosc; 2019 Dec; 73(12):1436-1450. PubMed ID: 31411494
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [A spike denoising method combined principal component analysis with wavelet and ensemble empirical mode decomposition].
    Zhou Y; Hu Y; Li M; Yang L; Shang Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2020 Apr; 37(2):271-279. PubMed ID: 32329279
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Denoising of HD-sEMG signals using canonical correlation analysis.
    Al Harrach M; Boudaoud S; Hassan M; Ayachi FS; Gamet D; Grosset JF; Marin F
    Med Biol Eng Comput; 2017 Mar; 55(3):375-388. PubMed ID: 27221811
    [TBL] [Abstract][Full Text] [Related]  

  • 31. EMDLAB: A toolbox for analysis of single-trial EEG dynamics using empirical mode decomposition.
    Al-Subari K; Al-Baddai S; Tomé AM; Goldhacker M; Faltermeier R; Lang EW
    J Neurosci Methods; 2015 Sep; 253():193-205. PubMed ID: 26162614
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A Discrete Curvature Estimation Based Low-Distortion Adaptive Savitzky⁻Golay Filter for ECG Denoising.
    Huang H; Hu S; Sun Y
    Sensors (Basel); 2019 Apr; 19(7):. PubMed ID: 30987283
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Eye blink artifact rejection in single-channel electroencephalographic signals by complete ensemble empirical mode decomposition and independent component analysis.
    Kanoga S; Mitsukura Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():121-4. PubMed ID: 26736215
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Denoising of surface electromyogram based on complementary ensemble empirical mode decomposition and improved interval thresholding.
    Xi X; Zhang Y; Zhao Y; She Q; Luo Z
    Rev Sci Instrum; 2019 Mar; 90(3):035003. PubMed ID: 30927792
    [TBL] [Abstract][Full Text] [Related]  

  • 35. ECG signal denoising via empirical wavelet transform.
    Singh O; Sunkaria RK
    Australas Phys Eng Sci Med; 2017 Mar; 40(1):219-229. PubMed ID: 28035635
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Anaesthetic EEG signal denoise using improved nonlocal mean methods.
    Li T; Wen P; Jayamaha S
    Australas Phys Eng Sci Med; 2014 Jun; 37(2):431-7. PubMed ID: 24682852
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Denoising depth EEG signals during DBS using filtering and subspace decomposition.
    Hofmanis J; Caspary O; Louis-Dorr V; Ranta R; Maillard L
    IEEE Trans Biomed Eng; 2013 Oct; 60(10):2686-95. PubMed ID: 23674415
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A New Underwater Acoustic Signal Denoising Technique Based on CEEMDAN, Mutual Information, Permutation Entropy, and Wavelet Threshold Denoising.
    Li Y; Li Y; Chen X; Yu J; Yang H; Wang L
    Entropy (Basel); 2018 Jul; 20(8):. PubMed ID: 33265652
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Surface electromyography signal denoising via EEMD and improved wavelet thresholds.
    Sun Z; Xi X; Yuan C; Yang Y; Hua X
    Math Biosci Eng; 2020 Oct; 17(6):6945-6962. PubMed ID: 33378883
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Depth of anesthesia prediction via EEG signals using convolutional neural network and ensemble empirical mode decomposition.
    Madanu R; Rahman F; Abbod MF; Fan SZ; Shieh JS
    Math Biosci Eng; 2021 Jun; 18(5):5047-5068. PubMed ID: 34517477
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.