These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 25660946)

  • 1. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model.
    Park HS; Choo IW; Seo S; Hyun D; Lim S; Kim JJ; Hong SB; Min BH; Do YS; Choo SW; Shin SW; Park KB; Cho SK
    Gastrointest Endosc; 2015; 81(6):1433-8. PubMed ID: 25660946
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel animal model of gastrointestinal obstruction for the development of stent.
    Hyun D; Park HS; Seo S; Choo IW; Lim S; Nam MH; Do YS; Choo SW; Shin SW; Park KB; Cho SK
    J Surg Res; 2014 Apr; 187(2):445-9. PubMed ID: 24267615
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Wallstent and Ultraflex stents for palliation of malignant left-sided colon obstruction: a retrospective, case-matched analysis.
    Small AJ; Baron TH
    Gastrointest Endosc; 2008 Mar; 67(3):478-88. PubMed ID: 18294511
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is a flared stent effective for decreasing stent migration in canine prostatic urethra?
    Woo CW; Song HY; Yoon CJ; Kim TH; Kim EY; Kim JH; Shin JH
    Acta Radiol; 2008 Apr; 49(3):285-90. PubMed ID: 18365816
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Antimigration property of a newly designed covered metal stent for esophageal stricture: an in vivo animal study.
    Ji JS; Lee BI; Kim HK; Cho YS; Choi H; Kim BW; Kim SW; Kim SS; Chae HS; Choi KY; Maeng LS
    Gastrointest Endosc; 2011 Jul; 74(1):148-53. PubMed ID: 21704813
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Through-the-scope double colonic stenting in the management of inoperable proximal malignant colonic obstruction: a pilot study.
    Shim CS; Cho JY; Jung IS; Ryu CB; Hong SJ; Kim JO; Lee JS; Lee MS; Kim BS
    Endoscopy; 2004 May; 36(5):426-31. PubMed ID: 15100952
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stent placement for benign colonic stenosis: case report, review of the literature, and animal pilot data.
    Geiger TM; Miedema BW; Tsereteli Z; Sporn E; Thaler K
    Int J Colorectal Dis; 2008 Oct; 23(10):1007-12. PubMed ID: 18594837
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of uncovered stent with covered stent for treatment of malignant colorectal obstruction.
    Lee KM; Shin SJ; Hwang JC; Cheong JY; Yoo BM; Lee KJ; Hahm KB; Kim JH; Cho SW
    Gastrointest Endosc; 2007 Nov; 66(5):931-6. PubMed ID: 17767930
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incomplete large bowel obstruction caused by a duodenal stent.
    Harding CK; Parker MC
    Surg Endosc; 2001 Sep; 15(9):1043. PubMed ID: 11443438
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design, manufacture and evaluation of a NiTi stent for colon obstruction.
    Domingo S; Puértolas S; Gracia-Villa L; Mainar M; Usón J; Puértolas JA
    Biomed Mater Eng; 2005; 15(5):357-65. PubMed ID: 16179756
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Favorable long-term clinical outcome of uncovered D-weave stent placement as definitive palliative treatment for malignant colorectal obstruction.
    Tominaga K; Maetani I; Sato K; Shigoka H; Omuta S; Ito S; Saigusa Y
    Dis Colon Rectum; 2012 Sep; 55(9):983-9. PubMed ID: 22874606
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic placement of self-expandable metal stents for malignant colonic obstruction: long-term outcomes and complication factors.
    Small AJ; Coelho-Prabhu N; Baron TH
    Gastrointest Endosc; 2010 Mar; 71(3):560-72. PubMed ID: 20189515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stenting of the proximal colon in patients with malignant large bowel obstruction: techniques and outcomes.
    Repici A; Adler DG; Gibbs CM; Malesci A; Preatoni P; Baron TH
    Gastrointest Endosc; 2007 Nov; 66(5):940-4. PubMed ID: 17963881
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Risk factors for covered metallic stent migration in patients with distal malignant biliary obstruction due to pancreatic cancer.
    Nakai Y; Isayama H; Kogure H; Hamada T; Togawa O; Ito Y; Matsubara S; Arizumi T; Yagioka H; Mizuno S; Sasaki T; Yamamoto N; Hirano K; Tada M; Koike K
    J Gastroenterol Hepatol; 2014 Sep; 29(9):1744-9. PubMed ID: 24720610
    [TBL] [Abstract][Full Text] [Related]  

  • 15. When a Colonic Metal Stent Is Left in for Too Long: A Devastating Coloenteric Fistula from Stent Erosion and Migration.
    Lee H; Prabhakaran K; Krowsoski L; Anderson PL; Lombardo G
    Am Surg; 2019 Mar; 85(3):e182-e184. PubMed ID: 30947804
    [No Abstract]   [Full Text] [Related]  

  • 16. Stenting for malignant colonic obstruction: a comparison of efficacy and complications in colonic versus extracolonic malignancy.
    Keswani RN; Azar RR; Edmundowicz SA; Zhang Q; Ammar T; Banerjee B; Early DS; Jonnalagadda SS
    Gastrointest Endosc; 2009 Mar; 69(3 Pt 2):675-80. PubMed ID: 19251009
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Colorectal stenting for malignant and benign disease: outcomes in colorectal stenting.
    Suzuki N; Saunders BP; Thomas-Gibson S; Akle C; Marshall M; Halligan S
    Dis Colon Rectum; 2004 Jul; 47(7):1201-7. PubMed ID: 15164246
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Self expanding wall stents in malignant colorectal cancer: is complete obstruction a contraindication to stent placement?
    Stenhouse GJ; Page B; Rowan A; Giles L; Macdonald A
    Colorectal Dis; 2009 Oct; 11(8):854-8. PubMed ID: 18727716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial.
    Kitano M; Yamashita Y; Tanaka K; Konishi H; Yazumi S; Nakai Y; Nishiyama O; Uehara H; Mitoro A; Sanuki T; Takaoka M; Koshitani T; Arisaka Y; Shiba M; Hoki N; Sato H; Sasaki Y; Sato M; Hasegawa K; Kawabata H; Okabe Y; Mukai H
    Am J Gastroenterol; 2013 Nov; 108(11):1713-22. PubMed ID: 24042190
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Duodenal stent placement: a tale of two halves.
    Pee L; Muller AF
    Gastrointest Endosc; 2011 Jul; 74(1):202; discussion 203. PubMed ID: 21571267
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.