209 related articles for article (PubMed ID: 25671382)
1. Methylene blue-mediated electrocatalytic detection of hexavalent chromium.
Korshoj LE; Zaitouna AJ; Lai RY
Anal Chem; 2015 Mar; 87(5):2560-4. PubMed ID: 25671382
[TBL] [Abstract][Full Text] [Related]
2. Application of Calcium-Binding Motif of E-Cadherin for Electrochemical Detection of Pb(II).
Lotfi Zadeh Zhad HR; Lai RY
Anal Chem; 2018 Jun; 90(11):6519-6525. PubMed ID: 29767947
[TBL] [Abstract][Full Text] [Related]
3. Speciation of chromium using chronoamperometric biosensors based on screen-printed electrodes.
Calvo-Pérez A; Domínguez-Renedo O; Alonso-Lomillo MA; Arcos-Martínez MJ
Anal Chim Acta; 2014 Jun; 833():15-21. PubMed ID: 24909769
[TBL] [Abstract][Full Text] [Related]
4. Folding- and Dynamics-Based Electrochemical DNA Sensors.
Lai RY
Methods Enzymol; 2017; 589():221-252. PubMed ID: 28336065
[TBL] [Abstract][Full Text] [Related]
5. Hexavalent Chromium as an Electrocatalyst in DNA Sensing.
Lotfi Zadeh Zhad HR; Lai RY
Anal Chem; 2017 Dec; 89(24):13342-13348. PubMed ID: 29143529
[TBL] [Abstract][Full Text] [Related]
6. Molecular beacon mediated circular strand displacement strategy for constructing a ratiometric electrochemical deoxyribonucleic acid sensor.
Gao F; Du L; Zhang Y; Tang D; Du Y
Anal Chim Acta; 2015 Jul; 883():67-73. PubMed ID: 26088778
[TBL] [Abstract][Full Text] [Related]
7. Survey of Redox-Active Moieties for Application in Multiplexed Electrochemical Biosensors.
Kang D; Ricci F; White RJ; Plaxco KW
Anal Chem; 2016 Nov; 88(21):10452-10458. PubMed ID: 27659949
[TBL] [Abstract][Full Text] [Related]
8. Development of a "signal-on" electrochemical DNA sensor with an oligo-thymine spacer for point mutation detection.
Wu Y; Lai RY
Chem Commun (Camb); 2013 Apr; 49(33):3422-4. PubMed ID: 23503676
[TBL] [Abstract][Full Text] [Related]
9. Titanium dioxide-gold nanocomposite materials embedded in silicate sol-gel film catalyst for simultaneous photodegradation of hexavalent chromium and methylene blue.
Pandikumar A; Ramaraj R
J Hazard Mater; 2012 Feb; 203-204():244-50. PubMed ID: 22206972
[TBL] [Abstract][Full Text] [Related]
10. A highly sensitive and selective electrochemical sensor for determination of Cr(VI) in the presence of Cr(III) using modified multi-walled carbon nanotubes/quercetin screen-printed electrode.
Sadeghi S; Garmroodi A
Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4972-7. PubMed ID: 24094212
[TBL] [Abstract][Full Text] [Related]
11. DNA-mediated strand displacement facilitates sensitive electronic detection of antibodies in human serums.
Dou B; Yang J; Shi K; Yuan R; Xiang Y
Biosens Bioelectron; 2016 Sep; 83():156-61. PubMed ID: 27111124
[TBL] [Abstract][Full Text] [Related]
12. Amplified detection of femtomolar DNA based on a one-to-few recognition reaction between DNA-Au conjugate and target DNA.
Wang Z; Zhang J; Zhu C; Wu S; Mandler D; Marks RS; Zhang H
Nanoscale; 2014 Mar; 6(6):3110-5. PubMed ID: 24488333
[TBL] [Abstract][Full Text] [Related]
13. Electrochemical Gold(III) Sensor with High Sensitivity and Tunable Dynamic Range.
Wu Y; Lai RY
Anal Chem; 2016 Feb; 88(4):2227-33. PubMed ID: 26780489
[TBL] [Abstract][Full Text] [Related]
14. Electrochemical DNA biosensor for bovine papillomavirus detection using polymeric film on screen-printed electrode.
Nascimento GA; Souza EV; Campos-Ferreira DS; Arruda MS; Castelletti CH; Wanderley MS; Ekert MH; Bruneska D; Lima-Filho JL
Biosens Bioelectron; 2012; 38(1):61-6. PubMed ID: 22727626
[TBL] [Abstract][Full Text] [Related]
15. An Electrochemical DNA Biosensor for Carcinogenicity of Anticancer Compounds Based on Competition between Methylene Blue and Oligonucleotides.
Md Sani ND; Ariffin EY; Sheryn W; Shamsuddin MA; Heng LY; Latip J; Hasbullah SA; Hassan NI
Sensors (Basel); 2019 Nov; 19(23):. PubMed ID: 31766637
[TBL] [Abstract][Full Text] [Related]
16. Electrochemical Detection of Platinum(IV) Prodrug Satraplatin in Serum.
Wu Y; Lai RY
Anal Chem; 2015 Nov; 87(21):11092-7. PubMed ID: 26465061
[TBL] [Abstract][Full Text] [Related]
17. Signal-on electrochemical Y or junction probe detection of nucleic acid.
Shen Z; Nakayama S; Semancik S; Sintim HO
Chem Commun (Camb); 2012 Aug; 48(61):7580-2. PubMed ID: 22735181
[TBL] [Abstract][Full Text] [Related]
18. The utilization of SiNWs/AuNPs-modified indium tin oxide (ITO) in fabrication of electrochemical DNA sensor.
Rashid JI; Yusof NA; Abdullah J; Hashim U; Hajian R
Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():270-6. PubMed ID: 25491829
[TBL] [Abstract][Full Text] [Related]
19. Nafion® modified-screen printed gold electrodes and their carbon nanostructuration for electrochemical sensors applications.
García-González R; Fernández-Abedul MT; Costa-García A
Talanta; 2013 Mar; 107():376-81. PubMed ID: 23598237
[TBL] [Abstract][Full Text] [Related]
20. Gold-silver nanoparticles modified electrochemical sensor array for simultaneous determination of chromium(III) and chromium(VI) in wastewater samples.
Zhao K; Ge L; Wong TI; Zhou X; Lisak G
Chemosphere; 2021 Oct; 281():130880. PubMed ID: 34029966
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]