138 related articles for article (PubMed ID: 25674721)
1. Comparison of a self-inflating bulb syringe and a colorimetric CO2 indicator with capnography and radiography to detect the misdirection of naso/orogastric tubes into the airway of critically ill adult patients.
Smyrnios NA; Lenard R; Rajan S; Newman MS; Baker SP; Thakkar N; Wassef W; Ajmere NK; Irwin RS
Chest; 2015 Jun; 147(6):1523-1529. PubMed ID: 25674721
[TBL] [Abstract][Full Text] [Related]
2. Detection of inadvertent airway intubation during gastric tube insertion: Capnography versus a colorimetric carbon dioxide detector.
Burns SM; Carpenter R; Blevins C; Bragg S; Marshall M; Browne L; Perkins M; Bagby R; Blackstone K; Truwit JD
Am J Crit Care; 2006 Mar; 15(2):188-95. PubMed ID: 16501138
[TBL] [Abstract][Full Text] [Related]
3. Use of a colorimetric carbon dioxide sensor for nasoenteric feeding tube placement in critical care patients compared with clinical methods and radiography.
Munera-Seeley V; Ochoa JB; Brown N; Bayless A; Correia MI; Bryk J; Zenati M
Nutr Clin Pract; 2008; 23(3):318-21. PubMed ID: 18595865
[TBL] [Abstract][Full Text] [Related]
4. Comparison of a colorimetric end-tidal CO2 detector and an esophageal aspiration device for verifying endotracheal tube placement in the prehospital setting: a six-month experience.
Schaller RJ; Huff JS; Zahn A
Prehosp Disaster Med; 1997; 12(1):57-63. PubMed ID: 10166376
[TBL] [Abstract][Full Text] [Related]
5. Diagnostic accuracy of methods used to verify nasogastric tube position in mechanically ventilated adult patients: a systematic review.
Bennetzen LV; Håkonsen SJ; Svenningsen H; Larsen P
JBI Database System Rev Implement Rep; 2015 Jan; 13(1):188-223. PubMed ID: 26447016
[TBL] [Abstract][Full Text] [Related]
6. Diagnostic accuracy of end-tidal carbon dioxide detection in determining correct placement of nasogastric tube: An updated systematic review with meta-analysis.
Chau JPC; Liu X; Choi KC; Lo SHS; Lam SKY; Chan KM; Zhao J; Thompson DR
Int J Nurs Stud; 2021 Nov; 123():104071. PubMed ID: 34520886
[TBL] [Abstract][Full Text] [Related]
7. Colorimetric capnography to ensure correct nasogastric tube position.
Meyer P; Henry M; Maury E; Baudel JL; Guidet B; Offenstadt G
J Crit Care; 2009 Jun; 24(2):231-5. PubMed ID: 19327299
[TBL] [Abstract][Full Text] [Related]
8. Colorimetric capnography, a new procedure to ensure correct feeding tube placement in the intensive care unit: an evaluation of a local protocol.
Galbois A; Vitry P; Ait-Oufella H; Baudel JL; Guidet B; Maury E; Offenstadt G
J Crit Care; 2011 Aug; 26(4):411-4. PubMed ID: 20869196
[TBL] [Abstract][Full Text] [Related]
9. Rapid detection of oesophageal intubation: take care when using colorimetric capnometry.
Puntervoll SA; Søreide E; Jacewicz W; Bjelland E
Acta Anaesthesiol Scand; 2002 Apr; 46(4):455-7. PubMed ID: 11952450
[TBL] [Abstract][Full Text] [Related]
10. Capnometry and air insufflation for assessing initial placement of gastric tubes.
Elpern EH; Killeen K; Talla E; Perez G; Gurka D
Am J Crit Care; 2007 Nov; 16(6):544-9; quiz 550. PubMed ID: 17962498
[TBL] [Abstract][Full Text] [Related]
11. Confirmation of nasogastric tube placement by colorimetric indicator detection of carbon dioxide: a preliminary report.
Thomas BW; Falcone RE
J Am Coll Nutr; 1998 Apr; 17(2):195-7. PubMed ID: 9550464
[TBL] [Abstract][Full Text] [Related]
12. Increasing the safety of blind gastric tube placement in pediatric patients: the design and testing of a procedure using a carbon dioxide detection device.
Gilbert RT; Burns SM
J Pediatr Nurs; 2012 Oct; 27(5):528-32. PubMed ID: 21963778
[TBL] [Abstract][Full Text] [Related]
13. Colorimetric end-tidal CO2 detector for verification of endotracheal tube placement in out-of-hospital cardiac arrest.
Hayden SR; Sciammarella J; Viccellio P; Thode H; Delagi R
Acad Emerg Med; 1995 Jun; 2(6):499-502. PubMed ID: 7497049
[TBL] [Abstract][Full Text] [Related]
14. Capnography confirms correct feeding tube placement in intensive care unit patients.
Kindopp AS; Drover JW; Heyland DK
Can J Anaesth; 2001; 48(7):705-10. PubMed ID: 11495882
[TBL] [Abstract][Full Text] [Related]
15. The effect of vinegar on colorimetric end-tidal carbon dioxide determination after esophageal intubation.
Leong MT; Ghebrial J; Sturmann K; Hsu CK
J Emerg Med; 2005 Jan; 28(1):5-11. PubMed ID: 15656997
[TBL] [Abstract][Full Text] [Related]
16. Resistance of Colorimetric Carbon Dioxide Detectors Commonly Utilized in Neonates.
Brown MK; Lazarus DV; Gonzales SR; Rich WD; Wozniak MJ; Poeltler DM; Katheria AC
Respir Care; 2016 Aug; 61(8):1003-7. PubMed ID: 27048627
[TBL] [Abstract][Full Text] [Related]
17. Aspirated air capnography with esophageal detector device to confirm tracheal intubation in rapid sequence induction.
Ghabash M; Choueiry P; Matta M
Middle East J Anaesthesiol; 1998 Jun; 14(5):381-6. PubMed ID: 9785341
[TBL] [Abstract][Full Text] [Related]
18. Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.
Howes DW; Shelley ES; Pickett W
Can J Anaesth; 2005 Apr; 52(4):428-32. PubMed ID: 15814761
[TBL] [Abstract][Full Text] [Related]
19. Capnography: beyond the numbers.
Rhoades C; Thomas F
Air Med J; 2002; 21(2):43-8. PubMed ID: 11896372
[TBL] [Abstract][Full Text] [Related]
20. Monitoring end-tidal carbon dioxide.
Editors of Nursing 2007
Nursing; 2007 May; 37(5):48-9. PubMed ID: 17468629
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]