  • 1. A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation.
    Xu Q; Hu D; Duan B; He J
    IEEE Trans Neural Syst Rehabil Eng; 2015 Jul; 23(4):683-92. PubMed ID: 25680207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A fully implantable stimulator with wireless power and data transmission for experimental use in epidural spinal cord stimulation.
    Xu Q; Li J; Han W; Zhou H
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():7230-3. PubMed ID: 22256007
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A fully implanted programmable stimulator based on wireless communication for epidural spinal cord stimulation in rats.
    Zhou H; Xu Q; He J; Ren H; Zhou H; Zheng K
    J Neurosci Methods; 2012 Mar; 204(2):341-8. PubMed ID: 22085835
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Fully Implantable and Programmable Epidural Spinal Cord Stimulation System for Rats with Spinal Cord Injury.
    Mao G; Zhou Z; Su H; Chen Y; Zhang J; Zhang C; Wang Z; Lu X
    IEEE Trans Neural Syst Rehabil Eng; 2023 Jan; PP():. PubMed ID: 37018337
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modulation effects of epidural spinal cord stimulation on muscle activities during walking.
    Huang H; He J; Herman R; Carhart MR
    IEEE Trans Neural Syst Rehabil Eng; 2006 Mar; 14(1):14-23. PubMed ID: 16562627
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Fully Implantable Miniaturized Liquid Crystal Polymer (LCP)-Based Spinal Cord Stimulator for Pain Control.
    Yun S; Koh CS; Seo J; Shim S; Park M; Jung HH; Eom K; Chang JW; Kim SJ
    Sensors (Basel); 2022 Jan; 22(2):. PubMed ID: 35062462
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of optimal electrode configurations for epidural spinal cord stimulation in cervical spinal cord injured rats.
    Alam M; Garcia-Alias G; Shah PK; Gerasimenko Y; Zhong H; Roy RR; Edgerton VR
    J Neurosci Methods; 2015 May; 247():50-7. PubMed ID: 25791014
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Epidural Spinal Cord Stimulation Facilitates Immediate Restoration of Dormant Motor and Autonomic Supraspinal Pathways after Chronic Neurologically Complete Spinal Cord Injury.
    Darrow D; Balser D; Netoff TI; Krassioukov A; Phillips A; Parr A; Samadani U
    J Neurotrauma; 2019 Aug; 36(15):2325-2336. PubMed ID: 30667299
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Epidural Stimulation of Rat Spinal Cord at Lumbosacral Segment Using a Surface Electrode: A Computer Simulation Study.
    Xu Q; Kong L; Zhou H; He J
    IEEE Trans Neural Syst Rehabil Eng; 2017 Oct; 25(10):1763-1772. PubMed ID: 27834648
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Power and signal transmission protocol for a contactless subdural spinal cord stimulation device.
    Song SH; Gillies GT; Howard MA; Kuhnley B; Utz M
    Biomed Microdevices; 2013 Feb; 15(1):27-36. PubMed ID: 22892642
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Flexible active electrode arrays with ASICs that fit inside the rat's spinal canal.
    Giagka V; Demosthenous A; Donaldson N
    Biomed Microdevices; 2015 Dec; 17(6):106. PubMed ID: 26466839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Epidural spinal-cord stimulation facilitates recovery of functional walking following incomplete spinal-cord injury.
    Carhart MR; He J; Herman R; D'Luzansky S; Willis WT
    IEEE Trans Neural Syst Rehabil Eng; 2004 Mar; 12(1):32-42. PubMed ID: 15068185
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and In Vivo Test of a Batteryless and Fully Wireless Implantable Asynchronous Pacing System.
    Asif SM; Hansen J; Khan MS; Walden SD; Jensen MO; Braaten BD; Ewert DL
    IEEE Trans Biomed Eng; 2016 May; 63(5):1070-1081. PubMed ID: 26357395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging.
    Acikel V; Uslubas A; Atalar E
    Med Phys; 2015 Jul; 42(7):3922-31. PubMed ID: 26133593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a battery-free ultrasonically powered functional electrical stimulator for movement restoration after paralyzing spinal cord injury.
    Alam M; Li S; Ahmed RU; Yam YM; Thakur S; Wang XY; Tang D; Ng S; Zheng YP
    J Neuroeng Rehabil; 2019 Mar; 16(1):36. PubMed ID: 30850027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.
    Shon A; Chu JU; Jung J; Kim H; Youn I
    Sensors (Basel); 2017 Dec; 18(1):. PubMed ID: 29267230
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A low-cost multichannel wireless neural stimulation system for freely roaming animals.
    Alam M; Chen X; Fernandez E
    J Neural Eng; 2013 Dec; 10(6):066010. PubMed ID: 24162159
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Fully Integrated Wireless SoC for Motor Function Recovery After Spinal Cord Injury.
    Lo YK; Kuan YC; Culaclii S; Kim B; Wang PM; Chang CW; Massachi JA; Zhu M; Chen K; Gad P; Edgerton VR; Liu W
    IEEE Trans Biomed Circuits Syst; 2017 Jun; 11(3):497-509. PubMed ID: 28489550
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microbiological Evaluation of the Extension Wire and Percutaneous Epidural Lead Anchor Site Following a "2-Stage Cut-Down" Spinal Cord Stimulator Procedure.
    Lalkhen AG; Chincholkar M; Patel J
    Pain Pract; 2017 Sep; 17(7):886-891. PubMed ID: 27910210
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A dual-mode highly efficient class-E stimulator controlled by a low-Q class-E power amplifier through duty cycle.
    Chiu HW; Lu CC; Chuang JM; Lin WT; Lin CW; Kao MC; Lin ML
    IEEE Trans Biomed Circuits Syst; 2013 Jun; 7(3):243-55. PubMed ID: 23853324
    [TBL] [Abstract][Full Text] [Related]  