These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 25682293)

  • 1. Half bridge topology 500 V pulser for ultrasonic transducer excitation.
    Svilainis L; Chaziachmetovas A; Dumbrava V
    Ultrasonics; 2015 May; 59():79-85. PubMed ID: 25682293
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficient high voltage pulser for piezoelectric air coupled transducer.
    Svilainis L; Chaziachmetovas A; Dumbrava V
    Ultrasonics; 2013 Jan; 53(1):225-31. PubMed ID: 22742963
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Supply-Inverted Bipolar Pulser and Tx/Rx Switch for CMUTs Above the Process Limit for High Pressure Pulse Generation.
    Jung G; Pirouz A; Tekes C; Carpenter TM; Cowell D; Freear S; Ghovanloo M; Degertekin FL
    IEEE Sens J; 2019 Dec; 19(24):12050-12058. PubMed ID: 34079429
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays.
    Jung G; Tekes C; Pirouz A; Degertekin FL; Ghovanloo M
    IEEE Trans Circuits Syst II Express Briefs; 2018 Mar; 65(3):306-310. PubMed ID: 29962919
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Power MOSFET-diode-based limiter for high-frequency ultrasound systems.
    Choi H; Kim MG; Cummins TM; Hwang JY; Shung KK
    Ultrason Imaging; 2014 Oct; 36(4):317-30. PubMed ID: 24626565
    [TBL] [Abstract][Full Text] [Related]  

  • 6. IGBT-based kilovoltage pulsers for ultrasound measurement applications.
    Gammell PM; Harris GR
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Dec; 50(12):1722-8. PubMed ID: 14761043
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and development of ultrasonic bipolar square-wave pulser for non-destructive testing of concrete structures.
    Jain H; Tarpara EG; Patankar VH
    Rev Sci Instrum; 2020 Sep; 91(9):094704. PubMed ID: 33003783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and characterization of a high-power ultrasound driver with ultralow-output impedance.
    Lewis GK; Olbricht WL
    Rev Sci Instrum; 2009 Nov; 80(11):114704. PubMed ID: 19947748
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Crossed SMPS MOSFET-based protection circuit for high frequency ultrasound transceivers and transducers.
    Choi H; Shung KK
    Biomed Eng Online; 2014 Jun; 13():76. PubMed ID: 24924595
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.
    Choi H; Woo PC; Yeom JY; Yoon C
    Sensors (Basel); 2017 Apr; 17(4):. PubMed ID: 28375165
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A megahertz bandwidth dual amplifier for driving piezoelectric actuators and other highly capacitive loads.
    Fleming AJ
    Rev Sci Instrum; 2009 Oct; 80(10):104701. PubMed ID: 19895079
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low power high-performance radio frequency oscillator for driving ion traps.
    Jau YY; Benito FM; Partner H; Schwindt PD
    Rev Sci Instrum; 2011 Feb; 82(2):023118. PubMed ID: 21361584
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and development of water-immersible two-channel high-voltage spike pulser for under-water inspection and gauging of pipes.
    Kumar NP; Patankar VH
    Rev Sci Instrum; 2022 Jan; 93(1):014703. PubMed ID: 35104974
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimization of electrode size for aluminum-nitride matrix ultrasonic transducers in the frequency range above 200 MHz.
    Wei Y; Herzog T; Heuer H
    Ultrasonics; 2013 Mar; 53(3):739-44. PubMed ID: 23218910
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A 180-V
    Sun K; Gao Z; Gui P; Wang R; Oguzman I; Xu X; Vasanth K; Zhou Q; Shung KK
    IEEE Trans Circuits Syst II Express Briefs; 2015 Feb; 62(2):149-153. PubMed ID: 25914609
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Single-Chip High-Voltage Integrated Actuator for Biomedical Ultrasound Scanners.
    Hsia C; Hsiao YC; Huang YC
    Sensors (Basel); 2019 Nov; 19(23):. PubMed ID: 31757012
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quinary excitation method for pulse compression ultrasound measurements.
    Cowell DM; Freear S
    Ultrasonics; 2008 Apr; 48(2):98-108. PubMed ID: 18191432
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deep-collapse operation of capacitive micromachined ultrasonic transducers.
    Olcum S; Yamaner FY; Bozkurt A; Atalar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2475-83. PubMed ID: 22083780
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electromagnetic wave propagation in a fast pulse line ion accelerator.
    Behbahani RA; Diot Q; Kavanagh B; Serkova NJ; Miften M; Westerly DC
    Med Phys; 2019 Dec; 46(12):5714-5721. PubMed ID: 31622500
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Complete ultrasonic transducer characterization and its use for models and measurements.
    Schmerr LW; Lopez-Sanchez A; Huang R
    Ultrasonics; 2006 Dec; 44 Suppl 1():e753-7. PubMed ID: 16797047
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.