470 related articles for article (PubMed ID: 25687018)
1. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine.
Mizani F; Salmanzadeh Ardabili S; Ganjaliab MR; Faridbod F; Payehghadr M; Azmoodeh M
Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():861-868. PubMed ID: 25687018
[TBL] [Abstract][Full Text] [Related]
2. Nano-level monitoring of Er(III) by fabrication of coated graphite electrode based on newly synthesized Schiff base as neutral carrier.
Bandi KR; Upadhyay A; Singh AK; Jain AK
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():9-17. PubMed ID: 26952392
[TBL] [Abstract][Full Text] [Related]
3. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry.
Shamsipur M; Dezaki AS; Akhond M; Sharghi H; Paziraee Z; Alizadeh K
J Hazard Mater; 2009 Dec; 172(2-3):566-73. PubMed ID: 19640638
[TBL] [Abstract][Full Text] [Related]
4. PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids.
Abdel-Haleem FM; Saad M; Barhoum A; Bechelany M; Rizk MS
Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():140-148. PubMed ID: 29752082
[TBL] [Abstract][Full Text] [Related]
5. Construction and performance characteristics of polymeric membrane electrode and coated graphite electrode for the selective determination of Fe³⁺ ion.
Bandi KR; Singh AK; Upadhyay A
Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():187-93. PubMed ID: 24433903
[TBL] [Abstract][Full Text] [Related]
6. Highly selective potentiometric and colorimetric determinations of cobalt (II) ion using thiazole based ligands.
Singhal D; Singh AK; Upadhyay A
Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():216-24. PubMed ID: 25491823
[TBL] [Abstract][Full Text] [Related]
7. Potentiometric determination of trace amounts of aluminium utilizing polyvinyl chloride membrane and coated platinum sensors based on E-N'-(2-hydroxy-3-methoxybenzylidene) benzohydrazide.
Tajik S; Taher MA; Sheikhshoaie I
J AOAC Int; 2013; 96(1):204-11. PubMed ID: 23513978
[TBL] [Abstract][Full Text] [Related]
8. Nano-level monitoring of Mn(2+) ion by fabrication of coated pyrolytic graphite electrode based on isonicotinohydrazide derivatives.
Sahani MK; Singh AK; Jain AK
Mater Sci Eng C Mater Biol Appl; 2015 May; 50():124-32. PubMed ID: 25746253
[TBL] [Abstract][Full Text] [Related]
9. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode.
Singh AK; Singh P; Bhattacharjee G
Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538
[TBL] [Abstract][Full Text] [Related]
10. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic.
Ganjali MR; Rezapour M; Pourjavid MR; Haghgoo S
Anal Sci; 2004 Jul; 20(7):1007-11. PubMed ID: 15293392
[TBL] [Abstract][Full Text] [Related]
11. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle.
Singh AK; Singh P
Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729
[TBL] [Abstract][Full Text] [Related]
12. Electroanalytical studies on Cu (II) ion-selective sensor of coated pyrolytic graphite electrodes based on N2S2O2 and N2S2O3 heterocyclic benzothiazol ligands.
Singh AK; Sahani MK; Bandi KR; Jain AK
Mater Sci Eng C Mater Biol Appl; 2014 Aug; 41():206-16. PubMed ID: 24907753
[TBL] [Abstract][Full Text] [Related]
13. Fabrication of coated graphite electrode for the selective determination of europium (III) ions.
Upadhyay A; Singh AK; Bandi KR; Jain AK
Talanta; 2013 Oct; 115():569-76. PubMed ID: 24054634
[TBL] [Abstract][Full Text] [Related]
14. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands.
Singh AK; Singh P; Banerjee S; Mehtab S
Anal Chim Acta; 2009 Feb; 633(1):109-18. PubMed ID: 19110124
[TBL] [Abstract][Full Text] [Related]
15. Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore.
Mahajan RK; Kamal A; Kumar N; Bhalla V; Kumar M
Environ Sci Pollut Res Int; 2013 May; 20(5):3086-97. PubMed ID: 23054787
[TBL] [Abstract][Full Text] [Related]
16. Electroanalytical and naked eye determination of Cu(2+) ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases.
Bandi KR; Singh AK; Upadhyay A
Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():149-57. PubMed ID: 24268244
[TBL] [Abstract][Full Text] [Related]
17. A comparative study on fabrication of Mn2+ selective polymeric membrane electrode and coated graphite electrode.
Singh AK; Bandi KR; Upadhyay A; Jain AK
Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):626-33. PubMed ID: 25427466
[TBL] [Abstract][Full Text] [Related]
18. Construction of a new selective coated disk electrode for Ag (I) based on modified polypyrrole-carbon nanotubes composite with new lariat ether.
Abbaspour A; Tashkhourian J; Ahmadpour S; Mirahmadi E; Sharghi H; Khalifeh R; Shahriyari MR
Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():326-33. PubMed ID: 24268265
[TBL] [Abstract][Full Text] [Related]
19. Highly selective potentiometric determination of mercury(II) ions using 1-furan-2-yl-4-(4-nitrophenyl)-2-phenyl-5H-imidazole-3-oxide based membrane electrodes.
Mahajan RK; Puri RK; Marwaha A; Kaur I; Mahajan MP
J Hazard Mater; 2009 Aug; 167(1-3):237-43. PubMed ID: 19185990
[TBL] [Abstract][Full Text] [Related]
20. Fabrication of novel coated pyrolytic graphite electrodes for the selective nano-level monitoring of Cd²⁺ ions in biological and environmental samples using polymeric membrane of newly synthesized macrocycle.
Sahani MK; Singh AK; Jain AK; Upadhyay A; Kumar A; Singh UP; Narang S
Anal Chim Acta; 2015 Feb; 860():51-60. PubMed ID: 25682247
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]