These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

454 related articles for article (PubMed ID: 25693343)

  • 1. [Intraoperative acute airway obstruction due to the damage of a reinforced endotracheal tube in thyroidectomy].
    Ida M; Kuzumoto N; Nakayama K; Krimoto K; Kamiya T; Iwata M; Shimomura T
    Masui; 2014 Oct; 63(10):1128-30. PubMed ID: 25693343
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia: case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 23931255
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative airway obstruction due to dissection of a reinforced endotracheal tube in a prone patient.
    Rajkumar A; Bajekal R
    J Neurosurg Anesthesiol; 2011 Oct; 23(4):377. PubMed ID: 21876451
    [No Abstract]   [Full Text] [Related]  

  • 5. The dissection of reinforced endotracheal tube internal wall causing intraoperative airway obstruction under general anesthesia. Case report.
    Mercanoglu E; Topuz D; Kaya N
    Braz J Anesthesiol; 2013; 63(4):372-4. PubMed ID: 24565248
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Obstruction of endotracheal tube; a manufacturing error.
    Hajimohammadi F; Taheri A; Eghtesadi-Araghi P
    Middle East J Anaesthesiol; 2009 Jun; 20(2):303-5. PubMed ID: 19583085
    [No Abstract]   [Full Text] [Related]  

  • 7. Silicone-based endotracheal tube causing airway obstruction and pneumothorax.
    Capra GG; Shah AN; Moore JD; Halsey WS; Lujan E
    Arch Otolaryngol Head Neck Surg; 2012 Jun; 138(6):588-91. PubMed ID: 22710512
    [No Abstract]   [Full Text] [Related]  

  • 8. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 9. Impending Complete Airway Obstruction from a Reinforced Orotracheal Tube: a Case Report.
    Hosseinzadeh N; Samadi S; Jafari Javid M; Takzare A
    Acta Med Iran; 2015; 53(9):590-2. PubMed ID: 26553090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impacted gum-elastic bougie in an endotracheal tube after successful intubation of a difficult airway.
    Arya VK; Makker S; Bedi SP
    J Clin Anesth; 2007 Nov; 19(7):566. PubMed ID: 18063220
    [No Abstract]   [Full Text] [Related]  

  • 11. [Case report of spiral endotracheal tube obstruction during anesthesia].
    Nosaka S; Tanaka N; Sakai T; Kiuchi A; Yoshikawa K
    Masui; 1986 Nov; 35(11):1732-5. PubMed ID: 3820565
    [No Abstract]   [Full Text] [Related]  

  • 12. Airway obstruction by an unexpected equipment damage.
    Schober P; Loer SA; Schwarte LA
    J Clin Anesth; 2016 Aug; 32():59-61. PubMed ID: 27290946
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Case report: lumen obstruction with a Magill tube].
    Deller A; Weichel T
    Anasth Intensivther Notfallmed; 1990 Aug; 25(4):293-4. PubMed ID: 2221303
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
    Sharma A; Jain V; Mitra JK; Prabhakar H
    Middle East J Anaesthesiol; 2008 Feb; 19(4):909-11. PubMed ID: 18630777
    [No Abstract]   [Full Text] [Related]  

  • 15. [Obstruction of the left upper lobar bronchus by a double-lumen endotracheal tube. Apropos of a case].
    Pueyo JA; Fuentes R; Bustos A; Guerrero MI; Torres LM
    Rev Esp Anestesiol Reanim; 1992; 39(2):134. PubMed ID: 1594783
    [No Abstract]   [Full Text] [Related]  

  • 16. A Rare Airway Obstruction Caused by Dissection of a Reinforced Endotracheal Tube.
    Choi YH; Lee DH
    J Emerg Med; 2018 Apr; 54(4):e73-e75. PubMed ID: 29395694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laser endotracheal tube failure: kinking of the Rüsch Lasertubus resulting in near-total airway occlusion.
    Weingarten TN; Hein B; Long TR; Wass CT
    J Clin Anesth; 2004 Sep; 16(6):452-4. PubMed ID: 15567651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Internal blistering of armored latex endotracheal tubes].
    Rouco Martínez I; Catalá Puigbó E; Baxarias Gascón P
    Rev Esp Anestesiol Reanim; 1984; 31(5):208-10. PubMed ID: 6505343
    [No Abstract]   [Full Text] [Related]  

  • 19. Two cases of intraoperative herniation of the endotracheal tube cuff.
    Bergadano A; Moens Y; Schatzmann U
    Schweiz Arch Tierheilkd; 2004 Dec; 146(12):565-9. PubMed ID: 15630897
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An unusual case of cuff herniation.
    Treffers R; de Lange JJ
    Acta Anaesthesiol Belg; 1989; 40(1):87-90. PubMed ID: 2728836
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.