146 related articles for article (PubMed ID: 25694641)
1. Allergic reaction to polysulphone membrane dialyser masquerading as infection.
Mukaya JE; Jacobson MS; Esprit D; Ajayi T
BMJ Case Rep; 2015 Feb; 2015():. PubMed ID: 25694641
[TBL] [Abstract][Full Text] [Related]
2. Clinical manifestations of AB-amyloidosis: effects of biocompatibility and flux.
Schiffl H; Fischer R; Lang SM; Mangel E
Nephrol Dial Transplant; 2000 Jun; 15(6):840-5. PubMed ID: 10831638
[TBL] [Abstract][Full Text] [Related]
3. Dialysis filter type determines the acute effect of haemodialysis on endothelial function and oxidative stress.
Kosch M; Levers A; Fobker M; Barenbrock M; Schaefer RM; Rahn KH; Hausberg M
Nephrol Dial Transplant; 2003 Jul; 18(7):1370-5. PubMed ID: 12808175
[TBL] [Abstract][Full Text] [Related]
4. [Adverse reactions to polysulphone membrane dialyzers durind hemodialysis].
Arenas MD; Gil MT; Carretón MA; Moledous A; Albiach B
Nefrologia; 2007; 27(5):638-42. PubMed ID: 18045043
[TBL] [Abstract][Full Text] [Related]
5. Hypersensitivity reactions to synthetic haemodialysis membranes an emerging issue?
Alvarez-de Lara MA; Martín-Malo A
Nefrologia; 2014 Nov; 34(6):698-702. PubMed ID: 25415569
[No Abstract] [Full Text] [Related]
6. Acute reactions to polysulfone/polyethersulfone dialysers: literature review and management.
Boer WH; Liem Y; de Beus E; Abrahams AC
Neth J Med; 2017 Jan; 75(1):4-13. PubMed ID: 28124665
[TBL] [Abstract][Full Text] [Related]
7. Biocompatible dialysis membranes and oxidative stress in patients wih end-stage renal disease on maintenance haemodialysis.
Abdel-Naeem NM; Kandell NF; El-Shamaa AA; Harba TM; Abdel-Hady AA
J Egypt Soc Parasitol; 2005 Dec; 35(3 Suppl):1173-97. PubMed ID: 16363293
[TBL] [Abstract][Full Text] [Related]
8. Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulphone haemodialyser.
Huang WH; Lee YY; Shih LC
Nephrol Dial Transplant; 2008 Jan; 23(1):423-4. PubMed ID: 17893104
[No Abstract] [Full Text] [Related]
9. [Effect of hemodialysis with cuprophane and polysulfone membranes on counts of leukocytes, granulocytes, monocytes, lymphocytes and lymphocyte subsets].
Moczulski D; Zukowska-Szczechowska E; Grzeszczak W; Religa Z; Cichoń R; Szydłowska I
Pol Arch Med Wewn; 1994 Nov; 92(5):400-7. PubMed ID: 7885988
[TBL] [Abstract][Full Text] [Related]
10. Lymphocyte subsets in dialyser eluates: a new parameter of bioincompatibility?
Grooteman MP; Nube MJ; van Limbeek J; Schoorl M; van Houte AJ
Nephrol Dial Transplant; 1996 Jun; 11(6):1073-8. PubMed ID: 8671971
[TBL] [Abstract][Full Text] [Related]
11. Effect of dialysis flux and membrane material on dyslipidaemia and inflammation in haemodialysis patients.
Wanner C; Bahner U; Mattern R; Lang D; Passlick-Deetjen J
Nephrol Dial Transplant; 2004 Oct; 19(10):2570-5. PubMed ID: 15280524
[TBL] [Abstract][Full Text] [Related]
12. Clearance of ceftriaxone during haemodialysis using cuprophane, haemophane and polysulfone dialysers.
Gabutti L; Taminelli-Beltraminelli L; Marone C
Eur J Clin Pharmacol; 1997; 53(2):123-6. PubMed ID: 9403283
[TBL] [Abstract][Full Text] [Related]
13. Acute effect of haemodialysis on arterial stiffness: membrane bioincompatibility?
Mourad A; Carney S; Gillies A; Jones B; Nanra R; Trevillian P
Nephrol Dial Transplant; 2004 Nov; 19(11):2797-802. PubMed ID: 15340092
[TBL] [Abstract][Full Text] [Related]
14. Hypersensitivity reactions to synthetic haemodialysis membranes.
Sánchez-Villanueva RJ; González E; Quirce S; Díaz R; Alvarez L; Menéndez D; Rodríguez-Gayo L; Bajo MA; Selgas R
Nefrologia; 2014; 34(4):520-5. PubMed ID: 25036066
[TBL] [Abstract][Full Text] [Related]
15. [The effect of hemodialysis with frequent use of cuprophan and polysulfone membranes on activation of complement in patients with chronic renal failure].
Zukowska-Szczechowska E; Moczulski D; Grzeszczak W; Gosek K; Augustyn M; Staszewicz P
Pol Arch Med Wewn; 1996 Nov; 96(5):458-68. PubMed ID: 9091856
[TBL] [Abstract][Full Text] [Related]
16. Effect of permeability on indices of haemodialysis membrane biocompatibility.
Masaki T; Gilson J; Leypoldt JK; Cheung AK
Nephrol Dial Transplant; 1999 May; 14(5):1176-81. PubMed ID: 10344358
[TBL] [Abstract][Full Text] [Related]
17. Hypersensitivity to synthetic hemodialysis membranes.
Martín-Navarro JA; Gutiérrez-Sánchez MJ; Petkov-Stoyanov V
Nefrologia; 2014 Nov; 34(6):807-8. PubMed ID: 25415584
[No Abstract] [Full Text] [Related]
18. Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report.
Post JB
Am J Kidney Dis; 2010 Jun; 55(6):e25-8. PubMed ID: 20110145
[TBL] [Abstract][Full Text] [Related]
19. Relationship between dialyser type and signs and symptoms.
Levin NW; Zasuwa G
Nephrol Dial Transplant; 1993; 8 Suppl 2():30-9. PubMed ID: 8272250
[TBL] [Abstract][Full Text] [Related]
20. In vivo evaluation of cellular and inflammatory response to a new polyethersulfone membrane.
Stefoni S; Coli L; Cianciolo G; Donati G; Dalmastri V; Orlandi V; D'Addio F; Ramazzotti E
Contrib Nephrol; 2003; (138):68-79. PubMed ID: 12463148
[No Abstract] [Full Text] [Related]
[Next] [New Search]