These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

293 related articles for article (PubMed ID: 25697857)

  • 1. Internal anterior fixators for pelvic ring injuries: Do monaxial pedicle screws provide more stiffness than polyaxial pedicle screws?
    Eagan M; Kim H; Manson TT; Gary JL; Russell JP; Hsieh AH; O'Toole RV; Boulton CL
    Injury; 2015; 46(6):996-1000. PubMed ID: 25697857
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.
    Vigdorchik JM; Esquivel AO; Jin X; Yang KH; Onwudiwe NA; Vaidya R
    J Orthop Surg Res; 2012 Sep; 7():31. PubMed ID: 23017093
    [TBL] [Abstract][Full Text] [Related]  

  • 3. "Anterior subcutaneous pelvic internal fixator (INFIX), Is it safe?" A cadaveric study.
    Apivatthakakul T; Rujiwattanapong N
    Injury; 2016 Oct; 47(10):2077-2080. PubMed ID: 27546721
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study.
    Becker CA; Kammerlander C; Kußmaul AC; Woiczinski M; Thorwächter C; Zeckey C; Sommer F; Linhart C; Weidert S; Suero EM; Böcker W; Greiner A
    Biomed Eng Online; 2019 Mar; 18(1):38. PubMed ID: 30925898
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support.
    Chen SH; Mo Lin R; Chen HH; Tsai KJ
    BMC Musculoskelet Disord; 2007 Mar; 8():28. PubMed ID: 17349057
    [TBL] [Abstract][Full Text] [Related]  

  • 6. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.
    Mcdonald E; Theologis AA; Horst P; Kandemir U; Pekmezci M
    Eur J Trauma Emerg Surg; 2015 Dec; 41(6):665-71. PubMed ID: 26038006
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Anterior Subcutaneous Pelvic Ring Fixator: No Biomechanical Advantages Compared with External Fixation.
    Jordan MC; Brems AC; Heintel T; Jansen H; Hoelscher-Doht S; Meffert RH
    J Bone Joint Surg Am; 2019 Oct; 101(19):1724-1731. PubMed ID: 31577677
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally-invasive fixation for anterior pelvic ring disruptions.
    Cole PA; Dyskin EA; Gilbertson JA
    Injury; 2015 Sep; 46 Suppl 3():S27-34. PubMed ID: 26458296
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study.
    Becker CA; Kammerlander C; Cavalcanti Kußmaul A; Dotzauer F; Woiczinski M; Rubenbauer B; Sommer F; Linhart C; Weidert S; Zeckey C; Greiner A
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):1055-1061. PubMed ID: 30179721
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Less invasive lumbopelvic fixation technique using a percutaneous pedicle screw system for unstable pelvic ring fracture in a patient with severe multiple traumas.
    Yano S; Aoki Y; Watanabe A; Nakajima T; Takazawa M; Hirasawa H; Takahashi K; Nakagawa K; Nakajima A; Takahashi H; Orita S; Eguchi Y; Suzuki T; Ohtori S
    J Neurosurg Spine; 2017 Feb; 26(2):203-207. PubMed ID: 27716018
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Anterior Subcutaneous Pelvic Fixator (INFIX) in an Anterior Posterior Compression Type 3 Pelvic Fracture.
    Vaidya R; Tonnos F; Nasr K; Kanneganti P; Curtis G
    J Orthop Trauma; 2016 Aug; 30 Suppl 2():S21-2. PubMed ID: 27441929
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw-rod system: a retrospective study of 23 patients after 13.5 months.
    Hua X; Yan SG; Cui Y; Yin Z; Schreiner AJ; Schmidutz F
    Arch Orthop Trauma Surg; 2019 Apr; 139(4):489-496. PubMed ID: 30535810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.
    Vigdorchik JM; Esquivel AO; Jin X; Yang KH; Vaidya R
    Int Orthop; 2013 Jul; 37(7):1341-6. PubMed ID: 23645004
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally invasive treatment of unstable pelvic ring injuries with modified pedicle screw-rod fixator.
    Wu XT; Liu ZQ; Fu WQ; Zhao S
    J Int Med Res; 2018 Jan; 46(1):368-380. PubMed ID: 28661263
    [TBL] [Abstract][Full Text] [Related]  

  • 15. External fixation of the pelvic ring: an experimental study on the role of pin diameter, pin position, and parasymphyseal fixator pins.
    Ponsen KJ; Joosse P; Van Dijke GA; Snijders CJ
    Acta Orthop; 2007 Oct; 78(5):648-53. PubMed ID: 17966024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX.
    Reichel LM; MacCormick LM; Dugarte AJ; Rizkala AR; Graves SC; Cole PA
    Injury; 2018 Feb; 49(2):309-314. PubMed ID: 29277392
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Robot-assisted percutaneous screw placement combined with pelvic internal fixator for minimally invasive treatment of unstable pelvic ring fractures.
    Liu HS; Duan SJ; Liu SD; Jia FS; Zhu LM; Liu MC
    Int J Med Robot; 2018 Oct; 14(5):e1927. PubMed ID: 29920914
    [TBL] [Abstract][Full Text] [Related]  

  • 18. INFIX versus plating for pelvic fractures with disruption of the symphysis pubis.
    Vaidya R; Martin AJ; Roth M; Nasr K; Gheraibeh P; Tonnos F
    Int Orthop; 2017 Aug; 41(8):1671-1678. PubMed ID: 28078361
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparative study on external fixators of new configurations in the treatment of Tile C pelvic injury.
    Zhao Y; Ma Y; Wu H; Lian W; Li W; Jiang W
    Sci Rep; 2024 Apr; 14(1):9544. PubMed ID: 38664538
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation.
    MacCormick LM; Chen F; Gilbertson J; Khan S; Schroder LK; Bechtold JE; Cole PA
    Injury; 2019 Feb; 50(2):251-255. PubMed ID: 30447984
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.