These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

379 related articles for article (PubMed ID: 25700559)

  • 1. A new model of central lid margin apposition and tear film mixing in spontaneous blinking.
    Pult H; Korb DR; Murphy PJ; Riede-Pult BH; Blackie C
    Cont Lens Anterior Eye; 2015 Jun; 38(3):173-80. PubMed ID: 25700559
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The precorneal tear film as a fluid shell: the effect of blinking and saccades on tear film distribution and dynamics.
    Yokoi N; Bron AJ; Georgiev GA
    Ocul Surf; 2014 Oct; 12(4):252-66. PubMed ID: 25284771
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of blinking on tear dynamics.
    Palakuru JR; Wang J; Aquavella JV
    Invest Ophthalmol Vis Sci; 2007 Jul; 48(7):3032-7. PubMed ID: 17591869
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Architecture of the lid-cornea juncture.
    Fatt I
    CLAO J; 1992 Jul; 18(3):187-92. PubMed ID: 1499127
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Single-equation models for the tear film in a blink cycle: realistic lid motion.
    Heryudono A; Braun RJ; Driscoll TA; Maki KL; Cook LP; King-Smith PE
    Math Med Biol; 2007 Dec; 24(4):347-77. PubMed ID: 17947253
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between Corneal Sensation, Blinking, and Tear Film Quality.
    Nosch DS; Pult H; Albon J; Purslow C; Murphy PJ
    Optom Vis Sci; 2016 May; 93(5):471-81. PubMed ID: 27104591
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Post-blink tear film dynamics in healthy and dry eyes during spontaneous blinking.
    Szczesna-Iskander DH
    Ocul Surf; 2018 Jan; 16(1):93-100. PubMed ID: 28919238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new perspective on spontaneous blinks.
    Pult H; Riede-Pult BH; Murphy PJ
    Ophthalmology; 2013 May; 120(5):1086-91. PubMed ID: 23399377
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Menisci and fullness of the blink in dry eye.
    Harrison WW; Begley CG; Liu H; Chen M; Garcia M; Smith JA
    Optom Vis Sci; 2008 Aug; 85(8):706-14. PubMed ID: 18677235
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Kinetic analysis of tear interference images in aqueous tear deficiency dry eye before and after punctal occlusion.
    Goto E; Tseng SC
    Invest Ophthalmol Vis Sci; 2003 May; 44(5):1897-905. PubMed ID: 12714621
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spontaneous Blinking Kinetics on Paralytic Lagophthalmos After Lid Load with Gold Weight or Autogenous Temporalis Fascia Sling.
    Wambier SP; Garcia DM; Cruz AA; Messias A
    Curr Eye Res; 2016 Apr; 41(4):433-40. PubMed ID: 26016510
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blinking and upper eyelid morphology.
    Shew W; Muntz A; Dean SJ; Pult H; Wang MTM; Craig JP
    Cont Lens Anterior Eye; 2022 Dec; 45(6):101702. PubMed ID: 35599140
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationships between central tear film thickness and tear menisci of the upper and lower eyelids.
    Wang J; Aquavella J; Palakuru J; Chung S; Feng C
    Invest Ophthalmol Vis Sci; 2006 Oct; 47(10):4349-55. PubMed ID: 17003425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Blinking and corneal sensitivity.
    Collins M; Seeto R; Campbell L; Ross M
    Acta Ophthalmol (Copenh); 1989 Oct; 67(5):525-31. PubMed ID: 2589051
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spreading of the tears after a blink: velocity and stabilization time in healthy eyes.
    Owens H; Phillips J
    Cornea; 2001 Jul; 20(5):484-7. PubMed ID: 11413403
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Detection of the spontaneous blinking pattern of dry eye patients using the machine learning method].
    Zhang ZZ; Kuang RF; Wei ZY; Wang LY; Su GY; Ou ZH; Liang QF
    Zhonghua Yan Ke Za Zhi; 2022 Feb; 58(2):120-129. PubMed ID: 35144352
    [No Abstract]   [Full Text] [Related]  

  • 17. Blinking and tear break-up during four visual tasks.
    Himebaugh NL; Begley CG; Bradley A; Wilkinson JA
    Optom Vis Sci; 2009 Feb; 86(2):E106-14. PubMed ID: 19156014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tear-film lipid layer morphology and corneal sensation in the development of blinking in neonates and infants.
    Lawrenson JG; Birhah R; Murphy PJ
    J Anat; 2005 Mar; 206(3):265-70. PubMed ID: 15733299
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Kinematics of spontaneous, reflex, and conditioned eyelid movements in the alert cat.
    Gruart A; Blázquez P; Delgado-García JM
    J Neurophysiol; 1995 Jul; 74(1):226-48. PubMed ID: 7472326
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic changes of tear fluid after cosmetic transcutaneous lower blepharoplasty measured by optical coherence tomography.
    Shao C; Fu Y; Lu L; Chen J; Shen Q; Zhu H; Fan X
    Am J Ophthalmol; 2014 Jul; 158(1):55-63.e1. PubMed ID: 24709809
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.