These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

409 related articles for article (PubMed ID: 25701972)

  • 1. Transvenous extraction of cardiac rhythm device leads: a report of the experience from a single referral centre in Greece.
    Sideris S; Kasiakogias A; Pirounaki M; Gatzoulis K; Sotiropoulos I; Dilaveris P; Traxanas K; Vouliotis AI; Manakos K; Konstantinidis D; Trantalis G; Lymperiadis D; Stavropoulos G; Tousoulis D; Kallikazaros I
    Hellenic J Cardiol; 2015; 56(1):55-60. PubMed ID: 25701972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The analysis of indications and early results of transvenous lead extraction in patients with a pacemaker, ICD and CRT - single-center experience.
    Zabek A; Malecka B; Haberka K; Boczar K; Pfitzner R; Debski M; Lelakowski J
    Acta Cardiol; 2015 Dec; 70(6):685-92. PubMed ID: 26717217
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy and safety of transvenous lead extraction in 108 consecutive patients: a single-centre experience.
    Monsefi N; Waraich HS; Vamos M; Erath J; Sirat S; Moritz A; Hohnloser SH
    Interact Cardiovasc Thorac Surg; 2019 May; 28(5):704-708. PubMed ID: 30597017
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications.
    Jones SO; Eckart RE; Albert CM; Epstein LM
    Heart Rhythm; 2008 Apr; 5(4):520-5. PubMed ID: 18325849
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age.
    Kempa M; Budrejko S; Piepiorka M; Rogowski J; Raczak G; Kozłowski D
    Kardiol Pol; 2013; 71(2):130-5. PubMed ID: 23575705
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Incidence and Predictors of Perioperative Complications With Transvenous Lead Extractions: Real-World Experience With National Cardiovascular Data Registry.
    Sood N; Martin DT; Lampert R; Curtis JP; Parzynski C; Clancy J
    Circ Arrhythm Electrophysiol; 2018 Feb; 11(2):e004768. PubMed ID: 29453324
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction.
    Aytemir K; Yorgun H; Canpolat U; Şahiner ML; Kaya EB; Evranos B; Özer N
    Europace; 2016 Jul; 18(7):1043-8. PubMed ID: 26467403
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Occurrence and extraction of implantable cardioverter-defibrillator leads with conductor externalization.
    Maciąg A; Syska P; Sterliński M; Kołodzińska A; Oręziak A; Kuśmierski K; Marciniak-Emmons M; Przybylski A; Szumowski Ł; Opolski G; Szwed H
    Cardiol J; 2018; 25(2):221-228. PubMed ID: 28840589
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laser-assisted extraction of pacemaker and defibrillator leads: the role of the cardiac surgeon.
    Gaca JG; Lima B; Milano CA; Lin SS; Davis RD; Lowe JE; Smith PK
    Ann Thorac Surg; 2009 May; 87(5):1446-50; discussion 1450-1. PubMed ID: 19379883
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transvenous Lead Extraction in Adults With Congenital Heart Disease: Insights From a 20-Year Single-Center Experience.
    Gourraud JB; Chaix MA; Shohoudi A; Pagé P; Dubuc M; Thibault B; Poirier NC; Dore A; Marcotte F; Mongeon FP; Asgar AW; Ibrahim R; Khairy P; Mondésert B
    Circ Arrhythm Electrophysiol; 2018 Feb; 11(2):e005409. PubMed ID: 29437760
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.
    Oto A; Aytemir K; Canpolat U; Yorgun H; Şahiner L; Kaya EB; Kabakçi G; Tokgözoğlu L
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):834-40. PubMed ID: 22486778
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transvenous lead extraction at the time of cardiac implantable electronic device upgrade: Complexity, safety, and outcomes.
    Barakat AF; Wazni OM; Tarakji K; Saliba WI; Nimri N; Rickard J; Brunner M; Bhargava M; Kanj M; Baranowski B; Martin DO; Cantillon D; Callahan T; Dresing T; Niebauer M; Chung M; Lindsay BD; Wilkoff B; Hussein AA
    Heart Rhythm; 2017 Dec; 14(12):1807-1811. PubMed ID: 28842225
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extraction of looped transvenous pacing leads to reduce tricuspid regurgitation.
    Montgomery JA; Ellis CR; Crossley GH
    Pacing Clin Electrophysiol; 2017 Jun; 40(6):644-647. PubMed ID: 28369957
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endocardial pacemaker or defibrillator leads with infected vegetations: a single-center experience and consequences of transvenous extraction.
    Meier-Ewert HK; Gray ME; John RM
    Am Heart J; 2003 Aug; 146(2):339-44. PubMed ID: 12891205
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of a 10-year period of lead removal in a referral centre.
    Marinheiro R; Neves JP; Morgado F; Madeira M; Magro P; Carmo P; Adragão P
    Interact Cardiovasc Thorac Surg; 2020 Aug; 31(2):166-173. PubMed ID: 32464643
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads.
    Calvagna GM; Evola R; Scardace G; Valsecchi S
    Europace; 2009 Nov; 11(11):1505-9. PubMed ID: 19666895
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors and outcomes of patients requiring repeat transvenous lead extraction of pacemaker and defibrillator leads.
    Claridge S; Johnson J; Sadnan G; Behar JM; Porter B; Sieniewicz B; Jackson T; Webb J; Gould J; Sohal M; Hamid S; Patel N; Gill J; Rinaldi CA
    Pacing Clin Electrophysiol; 2018 Feb; 41(2):155-160. PubMed ID: 29314081
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transvenous Lead Extraction in Chronic Kidney Disease and Dialysis Patients With Infected Cardiac Devices.
    Barakat AF; Wazni OM; Tarakji KG; Callahan T; Nimri N; Saliba WI; Shah S; Abdur Rehman K; Rickard J; Brunner MP; Martin DO; Kanj M; Baranowski B; Cantillon D; Niebauer M; Dresing T; Lindsay BD; Wilkoff BL; Hussein AA
    Circ Arrhythm Electrophysiol; 2018 Jan; 11(1):e005706. PubMed ID: 29321192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transvenous extraction of pacing and defibrillator leads--a single-centre experience.
    Geselle PJ; Poesen R; Rega F; Koopman P; Nuyens D; Heidbuchel H; Willems R
    Acta Cardiol; 2012 Dec; 67(6):641-8. PubMed ID: 23393934
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differences in laser lead extraction of infected vs. non-infected leads.
    Pecha S; Castro L; Vogler J; Linder M; Gosau N; Willems S; Reichenspurner H; Hakmi S
    Heart Vessels; 2018 Oct; 33(10):1245-1250. PubMed ID: 29623393
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.