271 related articles for article (PubMed ID: 25708031)
1. No evidence of superiority in reducing outliers of component alignment for patient-specific instrumentation for total knee arthroplasty: a systematic review. Zhang QM; Chen JY; Li H; Chai W; Ni M; Zhang ZD; Yang F Orthop Surg; 2015 Feb; 7(1):19-25. PubMed ID: 25708031 [TBL] [Abstract][Full Text] [Related]
2. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty. Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929 [TBL] [Abstract][Full Text] [Related]
3. Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis. Tandogan RN; Kort NP; Ercin E; van Rooij F; Nover L; Saffarini M; Hirschmann MT; Becker R; Dejour D; Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2654-2665. PubMed ID: 33646370 [TBL] [Abstract][Full Text] [Related]
4. Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis. Mannan A; Smith TO Knee; 2016 Mar; 23(2):186-90. PubMed ID: 26782300 [TBL] [Abstract][Full Text] [Related]
5. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting. Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634 [TBL] [Abstract][Full Text] [Related]
6. Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty. Huijbregts HJ; Khan RJ; Sorensen E; Fick DP; Haebich S Acta Orthop; 2016 Aug; 87(4):386-94. PubMed ID: 27249110 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis. An VV; Sivakumar BS; Phan K; Levy YD; Bruce WJ J Orthop Sci; 2017 Jan; 22(1):116-120. PubMed ID: 27823847 [TBL] [Abstract][Full Text] [Related]
8. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial. Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560 [TBL] [Abstract][Full Text] [Related]
9. Patient-specific instrumentation does not improve alignment in total knee arthroplasty. Russell R; Brown T; Huo M; Jones R J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637 [TBL] [Abstract][Full Text] [Related]
10. Patient-specific instrumentation improved three-dimensional accuracy in total knee arthroplasty: a comparative radiographic analysis of 1257 total knee arthroplasties. Pauzenberger L; Munz M; Brandl G; Frank JK; Heuberer PR; Laky B; Schwameis E; Anderl W J Orthop Surg Res; 2019 Dec; 14(1):437. PubMed ID: 31831022 [TBL] [Abstract][Full Text] [Related]
11. The efficacy and safety of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee arthroplasty: Evidence from a meta-analysis. Wang H; Zhang L; Teng X Medicine (Baltimore); 2024 Jan; 103(3):e36484. PubMed ID: 38241557 [TBL] [Abstract][Full Text] [Related]
12. Total knee arthroplasty in femoral bowing: does patient specific instrumentation have something to add? A randomized controlled trial. ALShammari SA; Choi KY; Koh IJ; Kim MS; In Y BMC Musculoskelet Disord; 2021 Apr; 22(1):321. PubMed ID: 33794854 [TBL] [Abstract][Full Text] [Related]
13. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759 [TBL] [Abstract][Full Text] [Related]
14. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Gong S; Xu W; Wang R; Wang Z; Wang B; Han L; Chen G Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1083-1095. PubMed ID: 30377714 [TBL] [Abstract][Full Text] [Related]
15. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes. Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377 [TBL] [Abstract][Full Text] [Related]
16. Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation. Yamamura K; Minoda Y; Mizokawa S; Ohta Y; Sugama R; Nakamura S; Ueyama H; Nakamura H Arch Orthop Trauma Surg; 2017 Mar; 137(3):401-407. PubMed ID: 28097422 [TBL] [Abstract][Full Text] [Related]