BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 25714439)

  • 1. Dynamic Locked Plating of Distal Femur Fractures.
    Linn MS; McAndrew CM; Prusaczyk B; Brimmo O; Ricci WM; Gardner MJ
    J Orthop Trauma; 2015 Oct; 29(10):447-50. PubMed ID: 25714439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw System.
    Canadian Orthopaedic Trauma Society
    J Orthop Trauma; 2016 Jan; 30(1):e1-6. PubMed ID: 26429408
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases.
    Ricci WM; Streubel PN; Morshed S; Collinge CA; Nork SE; Gardner MJ
    J Orthop Trauma; 2014 Feb; 28(2):83-9. PubMed ID: 23760176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical Construct Characteristics Predisposing to Non-union After Locked Lateral Plating of Distal Femur Fractures.
    Rodriguez EK; Zurakowski D; Herder L; Hall A; Walley KC; Weaver MJ; Appleton PT; Vrahas M
    J Orthop Trauma; 2016 Aug; 30(8):403-8. PubMed ID: 27027801
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Are extreme distal periprosthetic supracondylar fractures of the femur too distal to fix using a lateral locked plate?
    Streubel PN; Gardner MJ; Morshed S; Collinge CA; Gallagher B; Ricci WM
    J Bone Joint Surg Br; 2010 Apr; 92(4):527-34. PubMed ID: 20357329
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
    Lujan TJ; Henderson CE; Madey SM; Fitzpatrick DC; Marsh JL; Bottlang M
    J Orthop Trauma; 2010 Mar; 24(3):156-62. PubMed ID: 20182251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Any Cortical Bridging Predicts Healing of Supracondylar Femur Fractures After Treatment With Locked Plating.
    Strotman PK; Karunakar MA; Seymour R; Lack WD
    J Orthop Trauma; 2017 Oct; 31(10):538-544. PubMed ID: 28538286
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic locked plating for fixation of distal femur fractures using near- cortical over-drilling: Preliminary results of a prospective observational study.
    Galal S
    J Clin Orthop Trauma; 2017; 8(3):215-219. PubMed ID: 28951637
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcome of periprosthetic distal femoral fractures following knee arthroplasty.
    Hoffmann MF; Jones CB; Sietsema DL; Koenig SJ; Tornetta P
    Injury; 2012 Jul; 43(7):1084-9. PubMed ID: 22348954
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures.
    Rodriguez EK; Boulton C; Weaver MJ; Herder LM; Morgan JH; Chacko AT; Appleton PT; Zurakowski D; Vrahas MS
    Injury; 2014 Mar; 45(3):554-9. PubMed ID: 24275357
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Open distal femur fractures treated with lateral locked implants: union, secondary bone grafting, and predictive parameters.
    Barei DP; Beingessner DM
    Orthopedics; 2012 Jun; 35(6):e843-6. PubMed ID: 22691655
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures.
    Bryant GK; Morshed S; Agel J; Henley MB; Barei DP; Taitsman LA; Nork SE
    Injury; 2009 Nov; 40(11):1180-6. PubMed ID: 19539924
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Locked plating of periprosthetic femur fractures above total knee arthroplasty.
    Hou Z; Bowen TR; Irgit K; Strohecker K; Matzko ME; Widmaier J; Smith WR
    J Orthop Trauma; 2012 Jul; 26(7):427-32. PubMed ID: 22357080
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamization of locked plating on distal femur fracture.
    Oh JK; Hwang JH; Lee SJ; Kim JI
    Arch Orthop Trauma Surg; 2011 Apr; 131(4):535-9. PubMed ID: 21221613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technical Factors Contributing to Nonunion in Supracondylar Distal Femur Fractures Treated With Lateral Locked Plating: A Risk-Stratified Analysis.
    Stockton DJ; O'Hara NN; Brodke DJ; McKibben N; Healey K; Goch A; Demyanovich H; Devana S; Hernandez A; Burke CE; Gupta J; Marchand LS; Dekeyser GJ; Steffenson L; Shymon SJ; Fairres MJ; Perdue PW; Barber C; Atassi OH; Mitchell TW; Working ZM; Black LO; El Naga AN; Roddy E; Hogue M; Gulbrandsen T; Morellato J; Gillon WH; Walters MM; Hempen E; Slobogean GP; Lee C; O'Toole RV
    J Orthop Trauma; 2024 Jan; 38(1):49-55. PubMed ID: 37559208
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures.
    Vallier HA; Immler W
    J Orthop Trauma; 2012 Jun; 26(6):327-32. PubMed ID: 22183200
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis.
    Doornink J; Fitzpatrick DC; Boldhaus S; Madey SM; Bottlang M
    J Trauma; 2010 Aug; 69(2):411-7. PubMed ID: 20699751
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
    Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.