These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
28. Numerical investigations of the haemodynamic changes associated with stent malapposition in an idealised coronary artery. Poon EK; Barlis P; Moore S; Pan WH; Liu Y; Ye Y; Xue Y; Zhu SJ; Ooi AS J Biomech; 2014 Sep; 47(12):2843-51. PubMed ID: 25132633 [TBL] [Abstract][Full Text] [Related]
29. Simulation of stent deployment in a realistic human coronary artery. Gijsen FJ; Migliavacca F; Schievano S; Socci L; Petrini L; Thury A; Wentzel JJ; van der Steen AF; Serruys PW; Dubini G Biomed Eng Online; 2008 Aug; 7():23. PubMed ID: 18684321 [TBL] [Abstract][Full Text] [Related]
30. Drug deposition in coronary arteries with overlapping drug-eluting stents. Rikhtegar F; Edelman ER; Olgac U; Poulikakos D; Kurtcuoglu V J Control Release; 2016 Sep; 238():1-9. PubMed ID: 27432751 [TBL] [Abstract][Full Text] [Related]
31. Self-expanding versus balloon-expandable stents in acute myocardial infarction: results from the APPOSITION II study: self-expanding stents in ST-segment elevation myocardial infarction. van Geuns RJ; Tamburino C; Fajadet J; Vrolix M; Witzenbichler B; Eeckhout E; Spaulding C; Reczuch K; La Manna A; Spaargaren R; García-García HM; Regar E; Capodanno D; Van Langenhove G; Verheye S JACC Cardiovasc Interv; 2012 Dec; 5(12):1209-19. PubMed ID: 23257368 [TBL] [Abstract][Full Text] [Related]
32. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening. LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918 [TBL] [Abstract][Full Text] [Related]
34. Optical coherence tomography findings after chronic total occlusion interventions: Insights from the "AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions" (ACE-CTO) study (NCT01012869). Sherbet DP; Christopoulos G; Karatasakis A; Danek BA; Kotsia A; Navara R; Michael TT; Roesle M; Rangan BV; Haagen D; Garcia S; Maniu C; Pershad A; Abdullah SM; Hastings JL; Kumbhani DJ; Luna M; Addo T; Banerjee S; Brilakis ES Cardiovasc Revasc Med; 2016; 17(7):444-449. PubMed ID: 27133499 [TBL] [Abstract][Full Text] [Related]
35. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Finn AV; Joner M; Nakazawa G; Kolodgie F; Newell J; John MC; Gold HK; Virmani R Circulation; 2007 May; 115(18):2435-41. PubMed ID: 17438147 [TBL] [Abstract][Full Text] [Related]
36. Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage. Nam HS; Kim CS; Lee JJ; Song JW; Kim JW; Yoo H Med Phys; 2016 Apr; 43(4):1662. PubMed ID: 27036565 [TBL] [Abstract][Full Text] [Related]
37. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling. LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592 [TBL] [Abstract][Full Text] [Related]
38. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551 [TBL] [Abstract][Full Text] [Related]
39. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study. Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717 [TBL] [Abstract][Full Text] [Related]
40. Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion. Lim D; Cho SK; Park WP; Kristensson A; Ko JY; Al-Hassani ST; Kim HS Ann Biomed Eng; 2008 Jul; 36(7):1118-29. PubMed ID: 18437572 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]