BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 25720972)

  • 1. Absorbable sternal pins improve sternal closure stability within a small deviation.
    Koshiyama H; Yamazaki K
    Gen Thorac Cardiovasc Surg; 2015 Jun; 63(6):331-4. PubMed ID: 25720972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical study of a poly-L-lactide (PLLA) sternal pin in sternal closure after cardiothoracic surgery.
    Saito T; Iguchi A; Sakurai M; Tabayashi K
    Ann Thorac Surg; 2004 Feb; 77(2):684-7. PubMed ID: 14759459
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of two types of sternal pins used for sternal closure: poly-L-lactide sternal pins versus uncalcined hydroxyapatite poly-L-lactide sternal pins.
    Fu XM; Oshima H; Araki Y; Narita Y; Mutsuga M; Okada N; Tsunekawa T; Usui A
    J Artif Organs; 2013 Dec; 16(4):458-63. PubMed ID: 23996506
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Corrugated Sheet of Unsintered Hydroxyapatite Poly-L-Lactide for Sternal Fixation: A Preclinical Study.
    Kuroki H; Arai H; Srisont S; Oi K; Tomita M; Mizuno T
    Ann Thorac Cardiovasc Surg; 2020 Feb; 26(1):40-46. PubMed ID: 31827020
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of the sternum for sternal closure with bioabsorbable sternal pins.
    Kawamura M; Masai T; Matsue H; Yoshikawa Y; Sawa Y
    Asian Cardiovasc Thorac Ann; 2013 Jun; 21(3):331-4. PubMed ID: 24570501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reabsorbable Pins can Reinforce an Early Sternal Stability After Median Sternotomy in Young Children with Congenital Heart Disease.
    Fan C; Tang M; Wu S; Yuan S; Borovjagin AV; Yang J
    Pediatr Cardiol; 2019 Dec; 40(8):1728-1734. PubMed ID: 31549187
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of internal fixation of the sternum using bioabsorbable pins in small children.
    Ando M
    J Card Surg; 2019 Oct; 34(10):983-987. PubMed ID: 31374584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The application of poly (L-lactide) sternal coaptation pins for median sternotomy].
    Sakurada A; Sagawa M; Satoh M; Tanita T; Matsumura Y; Okada Y; Suzuki S; Fujimura S; Kondo T
    Kyobu Geka; 2000 Nov; 53(12):1011-2. PubMed ID: 11079305
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical studies of bioabsorbable poly-L-lactide sternal coaptation pins.
    Tanaka T; Okawa Y; Ishida N; Toyama M; Hashimoto M; Matsumoto K
    J Cardiovasc Surg (Torino); 2001 Dec; 42(6):749-51. PubMed ID: 11698940
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A biomechanical comparison of three sternotomy closure techniques.
    Cohen DJ; Griffin LV
    Ann Thorac Surg; 2002 Feb; 73(2):563-8. PubMed ID: 11845875
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Randomized, multicenter trial comparing sternotomy closure with rigid plate fixation to wire cerclage.
    Allen KB; Thourani VH; Naka Y; Grubb KJ; Grehan J; Patel N; Guy TS; Landolfo K; Gerdisch M; Bonnell M; Cohen DJ
    J Thorac Cardiovasc Surg; 2017 Apr; 153(4):888-896.e1. PubMed ID: 27923485
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical analysis of midline sternotomy wound closure.
    McGregor WE; Trumble DR; Magovern JA
    J Thorac Cardiovasc Surg; 1999 Jun; 117(6):1144-50. PubMed ID: 10343263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lower sternal reinforcement improves the stability of sternal closure.
    Dasika UK; Trumble DR; Magovern JA
    Ann Thorac Surg; 2003 May; 75(5):1618-21. PubMed ID: 12735589
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The Role of Corrugated Bioresorbable Sheet for Bone Fixation after Median Sternoto].
    Iwahashi D; Motoyoshi N
    Kyobu Geka; 2021 Mar; 74(3):181-186. PubMed ID: 33831869
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sternal closure with absorbable pins and cords in general thoracic surgery.
    Kawashima M; Sano A; Tanaka M
    Surg Today; 2015 Jul; 45(7):929-31. PubMed ID: 25432301
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sternal Pin Used to Close Sternum in Infants after Cardiac Surgery.
    Xie WP; Chen XH; Zhou SJ; Chen Q; Cao H
    Thorac Cardiovasc Surg; 2024 Jan; 72(1):77-83. PubMed ID: 37230479
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Evaluation of sternal deformity after pediatric minimally invasive cardiac surgery].
    Ishida R; Oiwa H; Honda K; Imamura K; Nonaka T; Sudo K
    Kyobu Geka; 2004 Feb; 57(2):111-4. PubMed ID: 14978903
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fatigue testing of three peristernal median sternotomy closure techniques.
    Wangsgard C; Cohen DJ; Griffin LV
    J Cardiothorac Surg; 2008 Sep; 3():52. PubMed ID: 18816402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A bioresorbable osteosynthesis device can induce an earlier sternal fusion after median sternotomy.
    Tsunekawa T; Usui A; Oshima H; Mizutani S; Araki Y; Okada N; Ueda Y
    Interact Cardiovasc Thorac Surg; 2012 Sep; 15(3):377-81. PubMed ID: 22623628
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Simple Technique of Sternal Closure Using An Absorbable Mesh Plate.
    Watanuki H; Futamura Y; Tochii M; Sugiyama K; Katsuhiko Matsuyama
    Heart Surg Forum; 2022 Feb; 25(1):E147-E151. PubMed ID: 35238296
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.