These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 25725875)

  • 1. Research on temperature measurement technology for graphite-cone-absorption-cavity absolute calorimeter.
    Wei JF; Lu F; Sun LQ; Zhang K; Hu XY; Zhou S; Xu D
    Rev Sci Instrum; 2015 Feb; 86(2):025001. PubMed ID: 25725875
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electro-optical equivalent calibration technology for high-energy laser energy meters.
    Wei JF; Chang Y; Sun LQ; Zhang K; Hu XY; Zhang W
    Rev Sci Instrum; 2016 Apr; 87(4):045114. PubMed ID: 27131714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Absolute reference calorimeter for measuring high power laser pulses.
    Franzen DL; Schmidt LB
    Appl Opt; 1976 Dec; 15(12):3115-22. PubMed ID: 20168401
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of temperature measurement error and its correction during Nd:YAG laser ablation in porcine pancreas.
    Schena E; Majocchi L
    Int J Hyperthermia; 2014 Aug; 30(5):328-34. PubMed ID: 25010146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermocouple error correction for measuring the flame temperature with determination of emissivity and heat transfer coefficient.
    Hindasageri V; Vedula RP; Prabhu SV
    Rev Sci Instrum; 2013 Feb; 84(2):024902. PubMed ID: 23464237
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Measurement of nonuniform temperature and concentration distribution by absorption spectroscopy based on least-square fitting].
    Song JL; Hong YJ; Wang GY; Pan H
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Aug; 33(8):2047-50. PubMed ID: 24159843
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Re-evaluation of correction factors of a primary standard graphite calorimeter in 60Co gamma ray beams as a basis for the appointment of the BEV absorbed dose rate to water reference value.
    Baumgartner A; Steurer A; Tiefenböck W; Gabris F; Maringer FJ; Kapsch RP; Stucki G
    Radiat Prot Dosimetry; 2011 Apr; 145(1):3-12. PubMed ID: 21112889
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Research on calorimeter for high-power microwave measurements.
    Ye H; Ning H; Yang W; Tian Y; Xiong Z; Yang M; Yan F; Cui X
    Rev Sci Instrum; 2015 Dec; 86(12):124706. PubMed ID: 26724055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak.
    Brunner D; LaBombard B
    Rev Sci Instrum; 2012 Mar; 83(3):033501. PubMed ID: 22462916
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of weak absorption in optical thin films.
    Jin SZ; Tang JF
    Appl Opt; 1987 Jun; 26(12):2407-9. PubMed ID: 20489883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Polystyrene-Water Calorimeter.
    Domen SR
    J Res Natl Bur Stand (1977); 1983; 88(6):373-387. PubMed ID: 34566110
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.
    Rapp B; Perichon N; Denoziere M; Daures J; Ostrowsky A; Bordy JM
    Phys Med Biol; 2013 May; 58(9):2769-86. PubMed ID: 23562978
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm.
    Davidson SR; Vitkin IA; Sherar MD; Whelan WM
    Lasers Surg Med; 2005 Apr; 36(4):297-306. PubMed ID: 15786482
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Worst-case losses from a cylindrical calorimeter for solar simulator calibration.
    Rowe SC; Groehn AJ; Palumbo AW; Chubukov BA; Clough DE; Weimer AW; Hischier I
    Opt Express; 2015 Sep; 23(19):A1309-23. PubMed ID: 26406760
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sensors-on-paper: Fabrication of graphite thermal sensor arrays on cellulose paper for large area temperature mapping.
    Mulla R; Dunnill CW
    HardwareX; 2022 Apr; 11():e00252. PubMed ID: 35509903
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New constant-temperature operating mode for graphite calorimeter at LNE-LNHB.
    Daures J; Ostrowsky A
    Phys Med Biol; 2005 Sep; 50(17):4035-52. PubMed ID: 16177528
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A high-temperature high-pressure calorimeter for determining heats of solution up to 623 K.
    Djamali E; Turner PJ; Murray RC; Cobble JW
    Rev Sci Instrum; 2010 Jul; 81(7):075105. PubMed ID: 20687757
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High accuracy laser power measurements: a scale comparison.
    Mohan K; James RH
    Appl Opt; 1979 Jun; 18(12):1937-40. PubMed ID: 20212582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Coaxial Thermocouples for Heat Transfer Measurements in Long-Duration High Enthalpy Flows.
    Zhang S; Wang Q; Li J; Zhang X; Chen H
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32937971
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements.
    Lundström H; Mattsson M
    Sensors (Basel); 2021 Oct; 21(19):. PubMed ID: 34640897
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.