117 related articles for article (PubMed ID: 25734810)
1. Use of a scissors forceps for the endoscopic removal of a distally migrated self-expandable metallic stent adhering to the duodenal mucosa.
Nishi Y; Naitoh I; Nakazawa T; Hayashi K; Miyabe K; Shimizu S; Joh T
Endoscopy; 2015; 47 Suppl 1 UCTN():E98-9. PubMed ID: 25734810
[No Abstract] [Full Text] [Related]
2. Open-biopsy-forceps technique for endoscopic removal of distally migrated and impacted biliary metallic stents.
Matsushita M; Takakuwa H; Nishio A; Kido M; Shimeno N
Gastrointest Endosc; 2003 Dec; 58(6):924-7. PubMed ID: 14652567
[TBL] [Abstract][Full Text] [Related]
3. Open-biopsy-forceps technique for removing biliary metallic stents that have migrated distally and wedged transversely in the duodenum.
Matsushita M; Uchida K; Okazaki K
Endoscopy; 2007 Jun; 39(6):570. PubMed ID: 17554657
[No Abstract] [Full Text] [Related]
4. Endoscopic retrieval of a distally migrated stent using detachable snares.
Yip HC; Chiu PW; Ng EK
Endoscopy; 2013; 45 Suppl 2 UCTN():E420-1. PubMed ID: 24338170
[No Abstract] [Full Text] [Related]
5. Endoscopic removal of a migrated duodenal stent into the ileum using double-balloon enteroscopy.
Gutierrez JP; Wilcox CM; Mönkemüller K
Gastrointest Endosc; 2015 Apr; 81(4):1033; discussion 1034. PubMed ID: 25432531
[No Abstract] [Full Text] [Related]
6. Endoscopic removal of a proximally migrated biliary metallic stent.
Wu C; Yang JF; Xu M; Liu W; Hu B
Endoscopy; 2017 Feb; 49(S 01):E99-E100. PubMed ID: 28192807
[No Abstract] [Full Text] [Related]
7. Endoscopic removal of migrated colonic self-expandable metallic stent using a sliding tube.
Moroi R; Kakuta Y; Endo K; Kuroha M; Kayaba S; Kinouchi Y; Shimosegawa T
Endoscopy; 2017 Oct; 49(10):E240-E241. PubMed ID: 28719932
[No Abstract] [Full Text] [Related]
8. Emergency endoscopic exploration of a pancreatic pseudocyst to retrieve a migrated pigtail stent.
Donatelli G; Dumont JL; Cereatti F; Tuszynski T; Calogero G; Vergeau BM; Meduri B
Endoscopy; 2017 Feb; 49(S 01):E51-E53. PubMed ID: 28068704
[No Abstract] [Full Text] [Related]
9. Revision of migrated self-expandable metal stent by the remOVE device.
Chua T; Fukami N
Endoscopy; 2018 Nov; 50(11):1129-1130. PubMed ID: 30107627
[No Abstract] [Full Text] [Related]
10. A safe technique for removing a malpositioned covered biliary self-expandable metal stent.
Koornstra JJ; van Dullemen HM; Weersma RK
Endoscopy; 2008 Sep; 40 Suppl 2():E165. PubMed ID: 18668454
[No Abstract] [Full Text] [Related]
11. Delayed removal of a deeply migrated pigtail pancreatic stent in a normal pancreatic duct.
Jung YK; Lee TH; Park SH; Choi HJ; Cha SW; Moon JH; Cho YD
Endoscopy; 2015; 47 Suppl 1 UCTN():E106-8. PubMed ID: 25734806
[No Abstract] [Full Text] [Related]
12. [New techniques to extract impacted partially covered metallic biliary stents].
Pérez Roldán F; González Carro PS; Legaz Huidobro ML; Roncero García-Escribano O; Sánchez-Manjavacas Muñoz N; Ynfante Ferrús M; Ruíz Carrillo F; Villafáñez García MC
Gastroenterol Hepatol; 2009; 32(7):489-94. PubMed ID: 19577341
[TBL] [Abstract][Full Text] [Related]
13. Removal of a deeply migrated pancreatic stent in a normal-size pancreatic duct using a modified snare with a cut plastic sheath.
Kim MJ; Han JH; Kang MH; Chae HB; Park SM; Youn SJ
Endoscopy; 2012; 44 Suppl 2 UCTN():E308-9. PubMed ID: 23011994
[No Abstract] [Full Text] [Related]
14. Closure of a duodenal stent-induced perforation by endoscopic stent removal and covered self-expandable metal stent placement (with video).
Small AJ; Petersen BT; Baron TH
Gastrointest Endosc; 2007 Nov; 66(5):1063-5. PubMed ID: 17767928
[No Abstract] [Full Text] [Related]
15. Endoscopic removal of migrated esophageal stent--the "grasper and pusher" method.
Martins B; Sorbello MP; Retes F; Kawaguti FS; Lima MS; Hondo FY; Stelko G; Ribeiro U; Maluf-Filho F
Endoscopy; 2012; 44 Suppl 2 UCTN():E10. PubMed ID: 22396251
[No Abstract] [Full Text] [Related]
16. Endotherapy for distally migrated metallic biliary endoprostheses.
Yarze JC
Gastrointest Endosc; 2006 May; 63(6):889-90. PubMed ID: 16650572
[No Abstract] [Full Text] [Related]
17. Endoscopic retrieval of a migrated esophageal stent using another anchored esophageal stent and an enteroscopy overtube: A novel technique.
Nakahara K; Itoh F
Dig Endosc; 2015 Sep; 27(6):709. PubMed ID: 25963954
[No Abstract] [Full Text] [Related]
18. Balloon extraction for the endoscopic removal of proximally migrated pancreatic stent.
He YQ; Wang JH; Tang S; Gao G; Sheng JQ
Endoscopy; 2014; 46 Suppl 1 UCTN():E186-7. PubMed ID: 24756287
[No Abstract] [Full Text] [Related]
19. Endoscopic removal of a migrated and long-indwelling self-expandable metal stent.
Zeng QS; Chen HL; Liu Q; Zeng HZ; Wang QM; Liu W; Hu B
Endoscopy; 2015; 47 Suppl 1 UCTN():E299-300. PubMed ID: 26099103
[No Abstract] [Full Text] [Related]
20. Endoscopic retrieval of a proximally migrated biliary plastic stent using a guidewire loop technique.
Lee JH; Yan SL; Chen CH; Yeh YH; Yueh SK
Endoscopy; 2014; 46 Suppl 1 UCTN():E232-3. PubMed ID: 24806373
[No Abstract] [Full Text] [Related]
[Next] [New Search]