These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 25751552)

  • 1. Update on cannulation techniques.
    Twardowski ZJ
    J Vasc Access; 2015; 16 Suppl 9():S54-60. PubMed ID: 25751552
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.
    Muir CA; Kotwal SS; Hawley CM; Polkinghorne K; Gallagher MP; Snelling P; Jardine MJ
    Clin J Am Soc Nephrol; 2014 Jan; 9(1):110-9. PubMed ID: 24370768
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.
    Wong B; Muneer M; Wiebe N; Storie D; Shurraw S; Pannu N; Klarenbach S; Grudzinski A; Nesrallah G; Pauly RP
    Am J Kidney Dis; 2014 Dec; 64(6):918-36. PubMed ID: 25110302
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cannulating in haemodialysis: rope-ladder or buttonhole technique?
    Verhallen AM; Kooistra MP; van Jaarsveld BC
    Nephrol Dial Transplant; 2007 Sep; 22(9):2601-4. PubMed ID: 17557776
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Arteriovenous fistula cannulation by buttonhole technique using dull needle.
    Castro MC; Silva Cde F; Souza JM; Assis MC; Aoki MV; Xagoraris M; Centeno JR; Souza JA
    J Bras Nefrol; 2010; 32(3):281-5. PubMed ID: 21103692
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical effects of buttonhole cannulation method on hemodialysis patients.
    Kim MK; Kim HS
    Hemodial Int; 2013 Apr; 17(2):294-9. PubMed ID: 22998500
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
    van Loon MM; Goovaerts T; Kessels AG; van der Sande FM; Tordoir JH
    Nephrol Dial Transplant; 2010 Jan; 25(1):225-30. PubMed ID: 19717827
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Con: Buttonhole cannulation of arteriovenous fistulae.
    Nadeau-Fredette AC; Johnson DW
    Nephrol Dial Transplant; 2016 Apr; 31(4):525-8. PubMed ID: 26994295
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Buttonhole Tunnel Tract Creation with the BioHole® Buttonhole Device.
    King J
    Contrib Nephrol; 2015; 186():21-32. PubMed ID: 26283556
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safe Needling of Arteriovenous Fistulae in Patients on Hemodialysis: Literature Review and a New Approach.
    Peralta R; Fazendeiro Matos J; Carvalho H
    Nephrol Nurs J; 2021; 48(2):169-176. PubMed ID: 33886247
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The buttonhole technique for fistula cannulation: pros and cons.
    Atkar RK; MacRae JM
    Curr Opin Nephrol Hypertens; 2013 Nov; 22(6):629-36. PubMed ID: 24076555
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of the BioHole™ device for the creation of tunnel tracks for buttonhole cannulation of fistula for hemodialysis.
    Marticorena RM; Hunter J; Macleod S; Petershofer E; Kashani M; DE LA Cruz J; Cook R; Dacoiris N; McFarlane PA; Goldstein MB; Donnelly SM
    Hemodial Int; 2011 Apr; 15(2):243-9. PubMed ID: 21251191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cannulation with sharp or blunt needles for haemodialysis: The importance of cannulation technique for the patient's lifeline.
    Staaf K; Uhlin F
    J Vasc Access; 2019 Mar; 20(2):161-168. PubMed ID: 30056775
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stenosis and thrombosis-unveiled complications of buttonhole cannulation.
    Moreira CL; Castro A; Silva F; Almeida P; de Matos AN; Sousa CN; Almeida R; Cabrita A; Queirós JA
    Hemodial Int; 2019 Jul; 23(3):E90-E92. PubMed ID: 30707492
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit.
    Marticorena RM; Hunter J; Cook R; Kashani M; Delacruz J; Petershofer E; Macleod S; Dacouris N; McFarlane PA; Donnelly SM; Goldstein MB
    Hemodial Int; 2009 Jul; 13(3):316-21. PubMed ID: 19515069
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A systematic review of buttonhole cannulation practices and outcomes.
    Grudzinski A; Mendelssohn D; Pierratos A; Nesrallah G
    Semin Dial; 2013; 26(4):465-75. PubMed ID: 23859189
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arteriovenous fistula survival with buttonhole (constant site) cannulation for hemodialysis access.
    Kandil H; Collier S; Yewetu E; Cross J; Davenport A
    ASAIO J; 2014; 60(1):95-8. PubMed ID: 24281124
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pro: Buttonhole cannulation of arteriovenous fistulae.
    Nesrallah GE
    Nephrol Dial Transplant; 2016 Apr; 31(4):520-3. PubMed ID: 26994293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial experience with the buttonhole technique in a Brazilian hemodialysis center.
    Silva Gdos S; Silva RA; Nicolino AM; Pavanetti LC; Alasmar VL; Guzzardi R; Zanolli MB; Guilhen JC; Araújo Ide M
    J Bras Nefrol; 2010; 32(3):257-62. PubMed ID: 21103688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Buttonhole Cannulation of Arteriovenous Fistulas in the United States.
    Vachharajani TJ; Wong L; Niyyar VD; Abreo KD; Mokrzycki MH
    Kidney360; 2020 Apr; 1(4):306-313. PubMed ID: 35372920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.