These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 25753144)

  • 1. Evaluation of the Microstat™ sublingual PCO2 monitor in ambulatory patients.
    Fox BD; Joyal D; Schlesinger RD; Eisenberg MJ; Langleben D
    J Clin Monit Comput; 2016 Feb; 30(1):77-80. PubMed ID: 25753144
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a transcutaneous blood gas monitoring system in critically ill dogs.
    Holowaychuk MK; Fujita H; Bersenas AM
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):545-53. PubMed ID: 25186166
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department.
    McVicar J; Eager R
    Emerg Med J; 2009 May; 26(5):344-6. PubMed ID: 19386868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates.
    Carter B; Hochmann M; Osborne A; Nisbet A; Campbell N
    Anaesth Intensive Care; 1995 Dec; 23(6):708-14. PubMed ID: 8669606
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Are transcutaneous blood gas measurement monitors (SenTec Digital Monitor system) useful for the respiratory management of chronic respiratory failure?].
    Yazawa R; Gamo M; Kokawa A; Hirose Y
    Masui; 2008 Apr; 57(4):453-6. PubMed ID: 18416203
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
    Carter R; Banham SW
    Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems.
    Bolliger D; Steiner LA; Kasper J; Aziz OA; Filipovic M; Seeberger MD
    Anaesthesia; 2007 Apr; 62(4):394-9. PubMed ID: 17381578
    [TBL] [Abstract][Full Text] [Related]  

  • 8. What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?
    van Oppen JD; Daniel PS; Sovani MP
    Respir Care; 2015 Apr; 60(4):484-91. PubMed ID: 25406345
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
    Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
    Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcutaneous carbon dioxide monitoring to avoid hypercapnia during complex catheter ablations: a feasibility study.
    Cantillon DJ; Keene LM; Hakim A; Spencer S; Petro J; Ludvik M; Schell D
    J Interv Card Electrophysiol; 2015 Sep; 43(3):307-11. PubMed ID: 25997689
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using transcutaneous carbon dioxide monitor (TOSCA 500) to detect respiratory failure in patients with amyotrophic lateral sclerosis: a validation study.
    Rafiq MK; Bradburn M; Proctor AR; Billings C; Bianchi S; McDermott CJ; Shaw PJ
    Amyotroph Lateral Scler; 2012 Oct; 13(6):528-32. PubMed ID: 22871078
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device.
    Janssens JP; Howarth-Frey C; Chevrolet JC; Abajo B; Rochat T
    Chest; 1998 Mar; 113(3):768-73. PubMed ID: 9515855
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical utility of sequential venous blood gas measurement in the assessment of ventilatory status during physiological stress.
    Wallbridge PD; Hannan LM; Joosten SA; Irving LB; Steinfort DP
    Intern Med J; 2013 Oct; 43(10):1075-80. PubMed ID: 23906178
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Simultaneous measurements of end-expiratory and transcutaneous carbon dioxide partial pressure in ventilated premature and newborn infants].
    Arsowa S; Schmalisch G; Wauer RR
    Klin Padiatr; 1997; 209(2):47-53. PubMed ID: 9198671
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sublingual capnometry tracks microcirculatory changes in septic patients.
    Creteur J; De Backer D; Sakr Y; Koch M; Vincent JL
    Intensive Care Med; 2006 Apr; 32(4):516-23. PubMed ID: 16485092
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Arterial-venous PCO2 gradient in early postoperative hours following myocardial revascularization.
    Cavaliere F; Martinelli L; Guarneri S; Varano C; Rossi M; Schiavello R
    J Cardiovasc Surg (Torino); 1996 Oct; 37(5):499-503. PubMed ID: 8941692
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors.
    Hirabayashi M; Fujiwara C; Ohtani N; Kagawa S; Kamide M
    J Anesth; 2009; 23(2):198-202. PubMed ID: 19444557
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements.
    Chakravarthy M; Narayan S; Govindarajan R; Jawali V; Rajeev S
    J Cardiothorac Vasc Anesth; 2010 Jun; 24(3):451-5. PubMed ID: 19729321
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.
    Sridhar MK; Carter R; Moran F; Banham SW
    Thorax; 1993 Jun; 48(6):643-7. PubMed ID: 8346496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.