241 related articles for article (PubMed ID: 25753774)
1. DWI using navigated interleaved multishot EPI with realigned GRAPPA reconstruction.
Liu W; Zhao X; Ma Y; Tang X; Gao JH
Magn Reson Med; 2016 Jan; 75(1):280-6. PubMed ID: 25753774
[TBL] [Abstract][Full Text] [Related]
2. Simultaneous multislice accelerated interleaved EPI DWI using generalized blipped-CAIPI acquisition and 3D K-space reconstruction.
Dai E; Ma X; Zhang Z; Yuan C; Guo H
Magn Reson Med; 2017 Apr; 77(4):1593-1605. PubMed ID: 27090059
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.
Liu C; Moseley ME; Bammer R
Magn Reson Med; 2005 Dec; 54(6):1412-22. PubMed ID: 16276497
[TBL] [Abstract][Full Text] [Related]
4. Improved multi-shot diffusion imaging using GRAPPA with a compact kernel.
Ma X; Zhang Z; Dai E; Guo H
Neuroimage; 2016 Sep; 138():88-99. PubMed ID: 27261163
[TBL] [Abstract][Full Text] [Related]
5. Interleaved EPI diffusion imaging using SPIRiT-based reconstruction with virtual coil compression.
Dong Z; Wang F; Ma X; Zhang Z; Dai E; Yuan C; Guo H
Magn Reson Med; 2018 Mar; 79(3):1525-1531. PubMed ID: 28608411
[TBL] [Abstract][Full Text] [Related]
6. Multishot cartesian turbo spin-echo diffusion imaging using iterative POCSMUSE Reconstruction.
Zhang Z; Zhang B; Li M; Liang X; Chen X; Liu R; Zhang X; Guo H
J Magn Reson Imaging; 2017 Jul; 46(1):167-174. PubMed ID: 27766699
[TBL] [Abstract][Full Text] [Related]
7. High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.
Jeong HK; Gore JC; Anderson AW
Magn Reson Med; 2013 Mar; 69(3):793-802. PubMed ID: 22592941
[TBL] [Abstract][Full Text] [Related]
8. Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.
Skare S; Newbould RD; Clayton DB; Albers GW; Nagle S; Bammer R
Magn Reson Med; 2007 May; 57(5):881-90. PubMed ID: 17457876
[TBL] [Abstract][Full Text] [Related]
9. Efficient parallel reconstruction for high resolution multishot spiral diffusion data with low rank constraint.
Liao C; Chen Y; Cao X; Chen S; He H; Mani M; Jacob M; Magnotta V; Zhong J
Magn Reson Med; 2017 Mar; 77(3):1359-1366. PubMed ID: 26968846
[TBL] [Abstract][Full Text] [Related]
10. POCS-enhanced inherent correction of motion-induced phase errors (POCS-ICE) for high-resolution multishot diffusion MRI.
Guo H; Ma X; Zhang Z; Zhang B; Yuan C; Huang F
Magn Reson Med; 2016 Jan; 75(1):169-80. PubMed ID: 25648591
[TBL] [Abstract][Full Text] [Related]
11. High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition.
Porter DA; Heidemann RM
Magn Reson Med; 2009 Aug; 62(2):468-75. PubMed ID: 19449372
[TBL] [Abstract][Full Text] [Related]
12. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).
Fries P; Runge VM; Kirchin MA; Stemmer A; Naul LG; Wiliams KD; Reith W; Bücker A; Schneider G
Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447
[TBL] [Abstract][Full Text] [Related]
13. High-resolution DTI of a localized volume using 3D single-shot diffusion-weighted STimulated echo-planar imaging (3D ss-DWSTEPI).
Jeong EK; Kim SE; Kholmovski EG; Parker DL
Magn Reson Med; 2006 Dec; 56(6):1173-81. PubMed ID: 17089367
[TBL] [Abstract][Full Text] [Related]
14. PEC-GRAPPA reconstruction of simultaneous multislice EPI with slice-dependent 2D Nyquist ghost correction.
Liu Y; Lyu M; Barth M; Yi Z; Leong ATL; Chen F; Feng Y; Wu EX
Magn Reson Med; 2019 Mar; 81(3):1924-1934. PubMed ID: 30368895
[TBL] [Abstract][Full Text] [Related]
15. Implementation and assessment of diffusion-weighted partial Fourier readout-segmented echo-planar imaging.
Frost R; Porter DA; Miller KL; Jezzard P
Magn Reson Med; 2012 Aug; 68(2):441-51. PubMed ID: 22535706
[TBL] [Abstract][Full Text] [Related]
16. Diffusion-weighted 3D multislab echo planar imaging for high signal-to-noise ratio efficiency and isotropic image resolution.
Engström M; Skare S
Magn Reson Med; 2013 Dec; 70(6):1507-14. PubMed ID: 23359357
[TBL] [Abstract][Full Text] [Related]
17. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.
Attenberger UI; Rathmann N; Sertdemir M; Riffel P; Weidner A; Kannengiesser S; Morelli JN; Schoenberg SO; Hausmann D
Z Med Phys; 2016 Jun; 26(2):168-76. PubMed ID: 26300045
[TBL] [Abstract][Full Text] [Related]
18. Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.
Hoge WS; Polimeni JR
Magn Reson Med; 2016 Jul; 76(1):32-44. PubMed ID: 26208304
[TBL] [Abstract][Full Text] [Related]
19. Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.
Hu Z; Ma X; Truong TK; Song AW; Guo H
Magn Reson Med; 2017 Jul; 78(1):172-181. PubMed ID: 27520840
[TBL] [Abstract][Full Text] [Related]
20. The effects of navigator distortion and noise level on interleaved EPI DWI reconstruction: a comparison between image- and k-space-based method.
Dai E; Zhang Z; Ma X; Dong Z; Li X; Xiong Y; Yuan C; Guo H
Magn Reson Med; 2018 Nov; 80(5):2024-2032. PubMed ID: 29569741
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]