BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 25759568)

  • 1. Inertial sensors as measurement tools of elbow range of motion in gerontology.
    Sacco G; Turpin JM; Marteu A; Sakarovitch C; Teboul B; Boscher L; Brocker P; Robert P; Guerin O
    Clin Interv Aging; 2015; 10():491-7. PubMed ID: 25759568
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of range-of-motion measurement in the elbow and forearm.
    Armstrong AD; MacDermid JC; Chinchalkar S; Stevens RS; King GJ
    J Shoulder Elbow Surg; 1998; 7(6):573-80. PubMed ID: 9883416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of the telemedicine-based goniometry for measuring elbow range of motion.
    Chanlalit C; Kongmalai P
    J Med Assoc Thai; 2012 Dec; 95 Suppl 12():S113-7. PubMed ID: 23513475
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of elbow position on the range of supination and pronation of the forearm.
    Shaaban H; Pereira C; Williams R; Lees VC
    J Hand Surg Eur Vol; 2008 Feb; 33(1):3-8. PubMed ID: 18332013
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validity and reliability of the GYKO inertial sensor system for the assessment of the elbow range of motion.
    Santospagnuolo A; Bruno AA; Pagnoni A; Martello F; Santoboni F; Perroni F; Vulpiani MC; Vetrano M
    J Sports Med Phys Fitness; 2019 Sep; 59(9):1466-1471. PubMed ID: 31610638
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Reliability of active range-of-motion measurement of the rotation in the forearm: comparison of three measurement devices].
    Urban V; Kalberer F; Roos M; Dumont CE
    Z Orthop Ihre Grenzgeb; 2002; 140(1):72-6. PubMed ID: 11898068
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison and reliability of three goniometric methods for measuring forearm supination and pronation.
    Gajdosik RL
    Percept Mot Skills; 2001 Oct; 93(2):353-5. PubMed ID: 11769888
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.
    Meislin MA; Wagner ER; Shin AY
    J Hand Surg Am; 2016 Apr; 41(4):510-515.e1. PubMed ID: 26880499
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects.
    Tousignant M; Boucher N; Bourbonnais J; Gravelle T; Quesnel M; Brosseau L
    Man Ther; 2001 Nov; 6(4):235-41. PubMed ID: 11673934
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The proximal and distal position of the radius relative to the ulna through a full range of elbow flexion and forearm rotation.
    Quigley RJ; Robicheaux GW; Lee TQ
    J Hand Surg Eur Vol; 2014 Jun; 39(5):535-40. PubMed ID: 23695153
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of Functional Ankle Motion Measures in Modern Dancers.
    Dickson D; Hollman-Gage K; Ojofeitimi S; Bronner S
    J Dance Med Sci; 2012 Sep; 16(3):116-25. PubMed ID: 26730940
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Range of motion measurements: reference values and a database for comparison studies.
    Soucie JM; Wang C; Forsyth A; Funk S; Denny M; Roach KE; Boone D;
    Haemophilia; 2011 May; 17(3):500-7. PubMed ID: 21070485
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of elbow position on the range of supination and pronation of the forearm, Shaaban et al., JHSE, 33E: 3-8.
    Hems TE
    J Hand Surg Eur Vol; 2009 Feb; 34(1):138-9; author reply 139. PubMed ID: 19270009
    [No Abstract]   [Full Text] [Related]  

  • 14. Elbow range of motion in professional baseball pitchers.
    Wright RW; Steger-May K; Wasserlauf BL; O'Neal ME; Weinberg BW; Paletta GA
    Am J Sports Med; 2006 Feb; 34(2):190-3. PubMed ID: 16219942
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variation in measurements of range of motion: a study in reflex sympathetic dystrophy patients.
    Geertzen JH; Dijkstra PU; Stewart RE; Groothoff JW; Ten Duis HJ; Eisma WH
    Clin Rehabil; 1998 Jun; 12(3):254-64. PubMed ID: 9688042
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Test-retest reproducibility of elbow goniometric measurements in a rigid double-blinded protocol: intervals for distinguishing between measurement error and clinical change.
    Cleffken B; van Breukelen G; van Mameren H; Brink P; Olde Damink S
    J Shoulder Elbow Surg; 2007; 16(6):788-794.e2. PubMed ID: 17967547
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validity and reliability of measurements of elbow flexion strength obtained from older adults using elastic bands.
    Manor B; Topp R; Page P
    J Geriatr Phys Ther; 2006; 29(1):18-21. PubMed ID: 16630372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a photography-based goniometry method for measuring joint range of motion.
    Blonna D; Zarkadas PC; Fitzsimmons JS; O'Driscoll SW
    J Shoulder Elbow Surg; 2012 Jan; 21(1):29-35. PubMed ID: 21983191
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Benefits of functional calibration for estimating elbow joint angles using magneto-inertial sensors: preliminary results.
    Bouvier B; Savescu A; Duprey S; Dumas R
    Comput Methods Biomech Biomed Engin; 2014; 17 Suppl 1():108-9. PubMed ID: 25074188
    [No Abstract]   [Full Text] [Related]  

  • 20. Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks.
    Sharma SP; Bærheim A; Kvåle A
    BMC Musculoskelet Disord; 2015 Feb; 16():37. PubMed ID: 25888419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.