These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 25763650)
1. Accurate calibration and uncertainty estimation of the normal spring constant of various AFM cantilevers. Song Y; Wu S; Xu L; Fu X Sensors (Basel); 2015 Mar; 15(3):5865-83. PubMed ID: 25763650 [TBL] [Abstract][Full Text] [Related]
2. Lateral force calibration for atomic force microscope cantilevers using a suspended nanowire. Zhang G; Li P; Wei D; Hu K; Qiu X Nanotechnology; 2020 Nov; 31(47):475703. PubMed ID: 32885790 [TBL] [Abstract][Full Text] [Related]
3. Accurate flexural spring constant calibration of colloid probe cantilevers using scanning laser Doppler vibrometry. Gates RS; Osborn WA; Shaw GA Nanotechnology; 2015 Jun; 26(23):235704. PubMed ID: 25990652 [TBL] [Abstract][Full Text] [Related]
4. A novel method and system for calibrating the spring constant of atomic force microscope cantilever based on electromagnetic actuation. Tian Y; Zhou C; Wang F; Zhang J; Guo Z; Zhang D Rev Sci Instrum; 2018 Dec; 89(12):125119. PubMed ID: 30599581 [TBL] [Abstract][Full Text] [Related]
5. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers. Yeh MK; Tai NH; Chen BY Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729 [TBL] [Abstract][Full Text] [Related]
6. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope. Sader JE; Lu J; Mulvaney P Rev Sci Instrum; 2014 Nov; 85(11):113702. PubMed ID: 25430115 [TBL] [Abstract][Full Text] [Related]
7. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration. Slattery AD; Blanch AJ; Quinton JS; Gibson CT Ultramicroscopy; 2013 Aug; 131():46-55. PubMed ID: 23685172 [TBL] [Abstract][Full Text] [Related]
8. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope. Rawlings C; Durkan C Nanotechnology; 2012 Dec; 23(48):485708. PubMed ID: 23137943 [TBL] [Abstract][Full Text] [Related]
9. Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry. Gates RS; Pratt JR Nanotechnology; 2012 Sep; 23(37):375702. PubMed ID: 22922668 [TBL] [Abstract][Full Text] [Related]
10. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers. Slattery AD; Blanch AJ; Quinton JS; Gibson CT Nanotechnology; 2013 Jan; 24(1):015710. PubMed ID: 23220746 [TBL] [Abstract][Full Text] [Related]
11. Characterizing the free and surface-coupled vibrations of heated-tip atomic force microscope cantilevers. Killgore JP; Tung RC; Hurley DC Nanotechnology; 2014 Aug; 25(34):345701. PubMed ID: 25098183 [TBL] [Abstract][Full Text] [Related]
12. Error in dynamic spring constant calibration of atomic force microscope probes due to nonuniform cantilevers. Frentrup H; Allen MS Nanotechnology; 2011 Jul; 22(29):295703. PubMed ID: 21673383 [TBL] [Abstract][Full Text] [Related]
13. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array. Gates RS; Reitsma MG Rev Sci Instrum; 2007 Aug; 78(8):086101. PubMed ID: 17764361 [TBL] [Abstract][Full Text] [Related]
14. Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties. Boudaoud M; Haddab Y; Le Gorrec Y; Lutz P Rev Sci Instrum; 2012 Jan; 83(1):013704. PubMed ID: 22299959 [TBL] [Abstract][Full Text] [Related]
15. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever. Yeh MK; Tai NH; Chen BY Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664 [TBL] [Abstract][Full Text] [Related]
16. Accuracy of the spring constant of atomic force microscopy cantilevers by finite element method. Chen BY; Yeh MK; Tai NH Anal Chem; 2007 Feb; 79(4):1333-8. PubMed ID: 17297931 [TBL] [Abstract][Full Text] [Related]
17. Spring constant calibration of atomic force microscope cantilevers of arbitrary shape. Sader JE; Sanelli JA; Adamson BD; Monty JP; Wei X; Crawford SA; Friend JR; Marusic I; Mulvaney P; Bieske EJ Rev Sci Instrum; 2012 Oct; 83(10):103705. PubMed ID: 23126772 [TBL] [Abstract][Full Text] [Related]
18. An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers. Li R; Ye H; Zhang W; Ma G; Su Y Sci Rep; 2015 Oct; 5():15828. PubMed ID: 26510769 [TBL] [Abstract][Full Text] [Related]