These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 25765271)

  • 21. Analysis of the interaction between tropomyosin allergens and antibodies using a biosensor based on imaging ellipsometry.
    Wang W; Qi C; Kang TF; Niu Y; Jin G; Ge YQ; Chen Y
    Anal Chem; 2013 May; 85(9):4446-52. PubMed ID: 23517013
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Measurement of specific surface energy of protein hydration shell using ESR of spin label].
    Rozhkov SP; Goriunov AS
    Biofizika; 2006; 51(2):236-41. PubMed ID: 16637327
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Microfluidic heavy metal immunoassay based on absorbance measurement.
    Date Y; Terakado S; Sasaki K; Aota A; Matsumoto N; Shiku H; Ino K; Watanabe Y; Matsue T; Ohmura N
    Biosens Bioelectron; 2012 Mar; 33(1):106-12. PubMed ID: 22244671
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Capture molecules preconditioned for kinetic analysis of high-affinity antigen-antibody complex in Biacore A100.
    Katayama M; Sato T; Kuromitsu J
    Anal Biochem; 2012 May; 424(2):168-77. PubMed ID: 22342884
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evanescent wave long-period fiber bragg grating as an immobilized antibody biosensor.
    DeLisa MP; Zhang Z; Shiloach M; Pilevar S; Davis CC; Sirkis JS; Bentley WE
    Anal Chem; 2000 Jul; 72(13):2895-900. PubMed ID: 10905324
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dense monolayers of metal-chelating ligands covalently attached to carbon electrodes electrochemically and their useful application in affinity binding of histidine-tagged proteins.
    Blankespoor R; Limoges B; Schöllhorn B; Syssa-Magalé JL; Yazidi D
    Langmuir; 2005 Apr; 21(8):3362-75. PubMed ID: 15807575
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Interaction of human hemoglobin with haptoglobin or antihemoglobin antibody.
    Sasazuki T; Tsunoo H; Nakajima H
    J Biol Chem; 1974 Apr; 249(8):2441-6. PubMed ID: 4132553
    [No Abstract]   [Full Text] [Related]  

  • 28. Label-free immunosensor based on Pd nanoplates for amperometric immunoassay of alpha-fetoprotein.
    Wang H; Li H; Zhang Y; Wei Q; Ma H; Wu D; Li Y; Zhang Y; Du B
    Biosens Bioelectron; 2014 Mar; 53():305-9. PubMed ID: 24161565
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Development of a label-free impedance biosensor for detection of antibody-antigen interactions based on a novel conductive linker.
    Chen CS; Chang KN; Chen YH; Lee CK; Lee BY; Lee AS
    Biosens Bioelectron; 2011 Feb; 26(6):3072-6. PubMed ID: 21185166
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A novel surface plasmon resonance biosensor based on graphene oxide decorated with gold nanorod-antibody conjugates for determination of transferrin.
    Zhang J; Sun Y; Xu B; Zhang H; Gao Y; Zhang H; Song D
    Biosens Bioelectron; 2013 Jul; 45():230-6. PubMed ID: 23500369
    [TBL] [Abstract][Full Text] [Related]  

  • 31. "Quenchbodies": quench-based antibody probes that show antigen-dependent fluorescence.
    Abe R; Ohashi H; Iijima I; Ihara M; Takagi H; Hohsaka T; Ueda H
    J Am Chem Soc; 2011 Nov; 133(43):17386-94. PubMed ID: 21977983
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Attachment of gold nanoparticles to glassy carbon electrode and its application for the direct electrochemistry and electrocatalytic behavior of hemoglobin.
    Zhang L; Jiang X; Wang E; Dong S
    Biosens Bioelectron; 2005 Aug; 21(2):337-45. PubMed ID: 16023961
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Displacement of molecules near a metal surface as seen by an SPR-SPFS biosensor.
    Ekgasit S; Yu F; Knoll W
    Langmuir; 2005 Apr; 21(9):4077-82. PubMed ID: 15835977
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Progress in immunoassay technology.
    Price CP
    Clin Chem Lab Med; 1998 Jun; 36(6):341-7. PubMed ID: 9711418
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Verification of the Universal Versatility of a Quantitative Protein Measurement Technique Using a Metal Mesh Device.
    Kamba S; Seto H; Kondo T; Miura Y
    Anal Sci; 2018; 34(7):765-770. PubMed ID: 29998956
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fractal analysis of antigen-antibody binding kinetics: biosensor applications.
    Sadana A; Ram AB
    Biotechnol Prog; 1994; 10(3):291-8. PubMed ID: 7764936
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hydrogen peroxide biosensor based on hemoglobin modified zirconia nanoparticles-grafted collagen matrix.
    Zong S; Cao Y; Zhou Y; Ju H
    Anal Chim Acta; 2007 Jan; 582(2):361-6. PubMed ID: 17386514
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Label-free liquid crystal biosensor for cecropin B detection.
    Zhang J; Su X; Yang D; Luan C
    Talanta; 2018 Aug; 186():60-64. PubMed ID: 29784409
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Force measurement for antigen-antibody interaction by atomic force microscopy using a photograft-polymer spacer.
    Idiris A; Kidoaki S; Usui K; Maki T; Suzuki H; Ito M; Aoki M; Hayashizaki Y; Matsuda T
    Biomacromolecules; 2005; 6(5):2776-84. PubMed ID: 16153118
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.
    Zhao C; Wan L; Jiang L; Wang Q; Jiao K
    Anal Biochem; 2008 Dec; 383(1):25-30. PubMed ID: 18783720
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.