These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 25766461)

  • 21. In vitro study of a modified sagittal split osteotomy fixation technique of the mandible: a mechanical test.
    Sonego CL; Scheffer MAR; Chagas Júnior OL; Vetromilla BM; Fernandes LP; Ozkomur A; Silva Júnior AN; Miguens Júnior SAQ; Hernandez PAG
    Int J Oral Maxillofac Surg; 2018 Oct; 47(10):1330-1335. PubMed ID: 29655819
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of the effect of mandibular length and height on the sagittal split ramus osteotomy rigid internal fixation techniques: A finite element analysis.
    Ergezen Ozasir E; Tosun E; Tuz HH
    J Stomatol Oral Maxillofac Surg; 2020 Dec; 121(6):652-657. PubMed ID: 32068168
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Removal of bicortical screws and other osteosynthesis material that caused symptoms after bilateral sagittal split osteotomy: a retrospective study of 251 patients, and review of published papers.
    Verweij JP; Houppermans PN; Mensink G; van Merkesteyn JP
    Br J Oral Maxillofac Surg; 2014 Oct; 52(8):756-60. PubMed ID: 24953784
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vitro biomechanical comparison of six different fixation methods following 5-mm sagittal split advancement osteotomies.
    Oguz Y; Watanabe ER; Reis JM; Spin-Neto R; Gabrielli MA; Pereira-Filho VA
    Int J Oral Maxillofac Surg; 2015 Aug; 44(8):984-8. PubMed ID: 25840861
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates--a numerical study.
    Albougha S; Albogha MH; Darwich MA; Darwich K
    Oral Maxillofac Surg; 2015 Sep; 19(3):281-5. PubMed ID: 25784154
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical analysis of titanium fixation plates and screws in sagittal split ramus osteotomies.
    Atik F; Atac MS; Özkan A; Kılınc Y; Arslan M
    Niger J Clin Pract; 2016; 19(1):140-4. PubMed ID: 26755233
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stability of locking and conventional 2.0-mm miniplate/screw systems after sagittal split ramus osteotomy: finite element analysis.
    Oguz Y; Uckan S; Ozden AU; Uckan E; Eser A
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Aug; 108(2):174-7. PubMed ID: 19615655
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniques.
    Ozden B; Alkan A; Arici S; Erdem E
    Int J Oral Maxillofac Surg; 2006 Sep; 35(9):837-41. PubMed ID: 16687240
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [The establishment of digital model about sagittal split ramus osteotomy and stability analysis of 3 different fixation methods].
    Yin XM; Zhang JW; Ren XX; Xu GX; Liu X
    Shanghai Kou Qiang Yi Xue; 2013 Jun; 22(3):241-6. PubMed ID: 23852049
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fixation Methods for Mandibular Advancement and Their Effects on Temporomandibular Joint: A Finite Element Analysis Study.
    Demircan S; Uretürk EU; Apaydın A; Şen S
    Biomed Res Int; 2020; 2020():2810763. PubMed ID: 32185199
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of five different fixation techniques of sagittal split ramus osteotomy using three-dimensional finite elements analysis.
    Sato FR; Asprino L; Noritomi PY; da Silva JV; de Moraes M
    Int J Oral Maxillofac Surg; 2012 Aug; 41(8):934-41. PubMed ID: 22510341
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading.
    Erkmen E; Simşek B; Yücel E; Kurt A
    Int J Oral Maxillofac Surg; 2005 Jul; 34(5):551-8. PubMed ID: 16053877
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Three Different Fixation Modalities following Mandibular Setback Surgery with Sagittal Split Ramus Osteotomy: A Comparative Study using Three-dimensional Finite Elements Analysis.
    Eshghpour M; Samieirad S; Shooshtari Z; Shams A; Ghadirimoghaddam N
    World J Plast Surg; 2023; 12(1):43-57. PubMed ID: 37220573
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mechanical evaluation of six techniques for stable fixation of the sagittal split osteotomy after counterclockwise mandibular advancement.
    De Oliveira LB; Reis JM; Spin-Neto R; Gabrielli MA; Oguz Y; Pereira-Filho VA
    Br J Oral Maxillofac Surg; 2016 Jun; 54(5):573-8. PubMed ID: 27068853
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparative study of biomechanical stability of resorbable and titanium fixation systems after sagittal split ramus osteotomy with a novel designed in-vitro testing unit.
    Ulu M; Soylu E; Kelebek S; Dikici S; Oflaz H
    J Craniomaxillofac Surg; 2018 Feb; 46(2):299-304. PubMed ID: 29295797
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vitro biomechanical evaluation of fixation methods of sagittal split ramus osteotomy in mandibular setback.
    Oh JS; Kim SG
    J Craniomaxillofac Surg; 2015 Mar; 43(2):186-91. PubMed ID: 25550092
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical in vitro evaluation of three stable internal fixation techniques used in sagittal osteotomy of the mandibular ramus: a study in sheep mandibles.
    Olivera LB; Sant' Ana E; Manzato AJ; Guerra FL; Arnett GW
    J Appl Oral Sci; 2012; 20(4):419-26. PubMed ID: 23032203
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparative study of skeletal stability between bicortical resorbable and titanium screw fixation after sagittal split ramus osteotomy for mandibular prognathism.
    Paeng JY; Hong J; Kim CS; Kim MJ
    J Craniomaxillofac Surg; 2012 Dec; 40(8):660-4. PubMed ID: 22209495
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparative evaluation of the sliding plate technique for fixation of a sagittal split ramus osteotomy: finite element analysis.
    Larson BE; Lee NK; Jang MJ; Jo DW; Yun PY; Kim YK
    Oral Surg Oral Med Oral Pathol Oral Radiol; 2017 May; 123(5):e148-e152. PubMed ID: 28153566
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A finite element analysis of stress distribution with various directions of intermaxillary fixation using orthodontic mini-implants and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy.
    Lee MY; Park JH; Park SJ; Chang NY; Chae JM
    Orthod Craniofac Res; 2024 Feb; 27(1):102-109. PubMed ID: 37496461
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.