These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
304 related articles for article (PubMed ID: 25769009)
1. Efficiency study of a big volume well type NaI(Tl) detector by point and voluminous sources and Monte-Carlo simulation. Hansman J; Mrdja D; Slivka J; Krmar M; Bikit I Appl Radiat Isot; 2015 May; 99():150-4. PubMed ID: 25769009 [TBL] [Abstract][Full Text] [Related]
2. Monte Carlo simulation of a NaI(Tl) detector for in situ radioactivity measurements in the marine environment. Zhang Y; Li C; Liu D; Zhang Y; Liu Y Appl Radiat Isot; 2015 Apr; 98():44-8. PubMed ID: 25635669 [TBL] [Abstract][Full Text] [Related]
3. Validation of gamma scanning method for optimizing NaI(Tl) detector model in Monte Carlo simulation. Chuong HD; Hung NQ; My Le NT; Nguyen VH; Thanh TT Appl Radiat Isot; 2019 Jul; 149():1-8. PubMed ID: 31003039 [TBL] [Abstract][Full Text] [Related]
4. Characterisation of a well-type NaI(Tl) detector by means of a Monte Carlo simulation for radionuclide metrology application. Heranudin ; Smith ML; van Wyngaardt WM; Guatelli S; Li E; Rosenfeld A Appl Radiat Isot; 2021 Oct; 176():109889. PubMed ID: 34375816 [TBL] [Abstract][Full Text] [Related]
5. Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4. Giubrone G; Ortiz J; Gallardo S; Martorell S; Bas MC J Environ Radioact; 2016 Jul; 158-159():114-8. PubMed ID: 27085040 [TBL] [Abstract][Full Text] [Related]
6. Efficiency of a cubic NaI(Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position. Abbas MI; Badawi MS; Thabet AA; Kopatch YN; Ruskov IN; Grozdanov DN; Noureddine S; Fedorov NA; Gouda MM; Hramco C; Abd-Elzaher M; Hamzawy A; Elsafi M; El-Khatib AM Appl Radiat Isot; 2020 Sep; 163():109139. PubMed ID: 32561067 [TBL] [Abstract][Full Text] [Related]
7. Correction of coincidence summing effects for add-back mode measurements with a 4π clover detector using experimental total efficiency. Yamashita T; Kamada H; Kojima Y; Shibata M Appl Radiat Isot; 2018 May; 135():131-134. PubMed ID: 29413827 [TBL] [Abstract][Full Text] [Related]
8. Design, construction and characterisation of a portable gamma-ray spectrometer for low-level natural occurring radioactive material ex-situ measurement. Bashir M; Newman RT; Jones P J Environ Radioact; 2020 Dec; 225():106415. PubMed ID: 33032005 [TBL] [Abstract][Full Text] [Related]
9. Beta-gamma coincidence counting efficiency and energy resolution optimization by Geant4 Monte Carlo simulations for a phoswich well detector. Zhang W; Mekarski P; Ungar K Appl Radiat Isot; 2010 Dec; 68(12):2377-81. PubMed ID: 20598559 [TBL] [Abstract][Full Text] [Related]
10. The determination of the efficiency of a Compton suppressed HPGe detector using Monte Carlo simulations. McNamara AL; Heijnis H; Fierro D; Reinhard MI J Environ Radioact; 2012 Apr; 106():1-7. PubMed ID: 22304994 [TBL] [Abstract][Full Text] [Related]
11. Efficiency calibration and coincidence summing correction for a large volume (946cm Dhibar M; Mankad D; Mazumdar I; Kumar GA Appl Radiat Isot; 2016 Dec; 118():32-37. PubMed ID: 27587372 [TBL] [Abstract][Full Text] [Related]
12. Optimization of the Monte Carlo simulation model of NaI(Tl) detector by Geant4 code. Duc Tam H; Hai Yen NT; Tran LB; Dinh Chuong H; Thien Thanh T Appl Radiat Isot; 2017 Dec; 130():75-79. PubMed ID: 28942332 [TBL] [Abstract][Full Text] [Related]
13. Estimation of background spectrum in a shielded HPGe detector using Monte Carlo simulations. Medhat ME; Wang Y Appl Radiat Isot; 2014 Feb; 84():13-8. PubMed ID: 24292007 [TBL] [Abstract][Full Text] [Related]
14. A Monte Carlo Method for Determining the Response Relationship between Two Commonly Used Detectors to Indirectly Measure Alpha Particle Radiation Activity. Tichacek CJ; Budzevich MM; Wadas TJ; Morse DL; Moros EG Molecules; 2019 Sep; 24(18):. PubMed ID: 31546752 [TBL] [Abstract][Full Text] [Related]
15. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples. Baccouche S; Al-Azmi D; Karunakara N; Trabelsi A Appl Radiat Isot; 2012 Jan; 70(1):227-32. PubMed ID: 21852143 [TBL] [Abstract][Full Text] [Related]
16. Dead layer estimation of an HPGe detector using MCNP6 and Geant4. Lee H; Sung SH; Shin SH; Kim HR Appl Radiat Isot; 2023 Feb; 192():110597. PubMed ID: 36508955 [TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulations to estimate the background spectrum in a shielded NaI(Tl) gamma-spectrometric system. Sengupta Mitra M; Sarkar PK Appl Radiat Isot; 2005 Oct; 63(4):415-22. PubMed ID: 15998590 [TBL] [Abstract][Full Text] [Related]
18. Determination of detection efficiency on HPGe detector for point-like and volumetric samples based on Geant4 simulations. Lin M; Wang Y; Qin Z Appl Radiat Isot; 2023 Oct; 200():110989. PubMed ID: 37611498 [TBL] [Abstract][Full Text] [Related]
19. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources. Yalcin S; Gurler O; Kaynak G; Gundogdu O Appl Radiat Isot; 2007 Oct; 65(10):1179-86. PubMed ID: 17611113 [TBL] [Abstract][Full Text] [Related]
20. A revision of the virtual point detector model for calculating Nai(Tl) detector efficiency. Chuong HD; Ngoc Trang LT; Nguyen VH; Thanh TT Appl Radiat Isot; 2020 Aug; 162():109179. PubMed ID: 32310091 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]