173 related articles for article (PubMed ID: 25771559)
1. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
Med Phys; 2015 Feb; 42(2):606-14. PubMed ID: 25771559
[TBL] [Abstract][Full Text] [Related]
2. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
Med Phys; 2015 Feb; 42(2):606-614. PubMed ID: 28102603
[TBL] [Abstract][Full Text] [Related]
3. A novel technique to optimise the length of a linear accelerator treatment room maze without compromising radiation protection.
Al-Affan IAM; Evans SC; Qutub M; Hugtenburg RP
J Radiol Prot; 2018 Mar; 38(1):48-60. PubMed ID: 28980530
[TBL] [Abstract][Full Text] [Related]
4. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
Al-Affan IA
Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo simulation of photons backscattering from various thicknesses of lead layered over concrete for energies 0.25-20 MeV using FLUKA code.
Al-Affan IAM; Qutub MAZ; Hugtenburg RP
Sci Rep; 2021 Sep; 11(1):18362. PubMed ID: 34526527
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo simulations of ceiling scatter in nuclear medicine:
Schnerr RS; de Jong AN; Landry G; Jeukens CR; Wierts R
Med Phys; 2017 Mar; 44(3):1113-1119. PubMed ID: 28097674
[TBL] [Abstract][Full Text] [Related]
7. Dose rates and energy spectra in the maze of a linear accelerator treatment room.
Morgan S; Morgan HM; Lillicrap SC
Br J Radiol; 1995 Nov; 68(815):1237-41. PubMed ID: 8542232
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.
McGinley PH; Dhaba'an AH; Reft CS
Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761
[TBL] [Abstract][Full Text] [Related]
9. Neutron scattering in concrete and wood: Part II--Oblique incidence.
Facure A; Silva AX; Rivera JC; Falcão RC
Radiat Prot Dosimetry; 2008; 128(3):367-74. PubMed ID: 17673488
[TBL] [Abstract][Full Text] [Related]
10. Determination of the photon spectrum of a therapeutic linear accelerator near the maze entrance: Comparison of Monte Carlo modeling and measurements using scintillation detectors corrected for pulse pile-up.
Qutub MAZ; Hugtenburg RP; Al-Affan IAM
Med Phys; 2020 Sep; 47(9):4522-4530. PubMed ID: 32469079
[TBL] [Abstract][Full Text] [Related]
11. Neutron scattering in concrete and wood.
Facure A; Silva AX; Falcão RC; Crispim VR
Radiat Prot Dosimetry; 2006; 119(1-4):514-7. PubMed ID: 16565202
[TBL] [Abstract][Full Text] [Related]
12. Radiation transmission and scattering for medical linacs producing x rays of 6 and 15 MV: comparison of calculations with measurements.
Numark NJ; Kase KR
Health Phys; 1985 Mar; 48(3):289-95. PubMed ID: 3920172
[TBL] [Abstract][Full Text] [Related]
13. Calculation of shielding door thicknesses for radiation therapy facilities using the ITS Monte Carlo program.
Biggs PJ
Health Phys; 1991 Oct; 61(4):465-72. PubMed ID: 1917483
[TBL] [Abstract][Full Text] [Related]
14. Shielding implications for secondary neutrons and photons produced within the patient during IMPT.
DeMarco J; Kupelian P; Santhanam A; Low D
Med Phys; 2013 Jul; 40(7):071701. PubMed ID: 23822405
[TBL] [Abstract][Full Text] [Related]
15. Characteristics of the photoneutron contamination present in a high-energy radiotherapy treatment room.
Garnica-Garza HM
Phys Med Biol; 2005 Feb; 50(3):531-9. PubMed ID: 15773728
[TBL] [Abstract][Full Text] [Related]
16. Does concrete composition affect photoneutron production inside radiation therapy bunkers?
Mesbahi A; Azarpeyvand AA; Khosravi HR
Jpn J Radiol; 2012 Feb; 30(2):162-6. PubMed ID: 22180187
[TBL] [Abstract][Full Text] [Related]
17. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
18. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
Falcão RC; Facure A; Silva AX
Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
[TBL] [Abstract][Full Text] [Related]
19. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
[TBL] [Abstract][Full Text] [Related]
20. Shielding Design for Adjacent, Underground Buildings of a Megavoltage Radiotherapy Facility.
Sanz DE
Health Phys; 2016 Jul; 111(1):1-10. PubMed ID: 27218288
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]