These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
64. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry. Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595 [TBL] [Abstract][Full Text] [Related]
65. Abnormal distortion of aortic corevalve bioprosthesis with suicide left ventricle, aortic insufficiency, and severe mitral regurgitation during transcatheter aortic valve replacement. Leya F; Tuchek JM; Coats W Catheter Cardiovasc Interv; 2016 Dec; 88(7):1181-1187. PubMed ID: 26945836 [TBL] [Abstract][Full Text] [Related]
66. Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation. Gripari P; Ewe SH; Fusini L; Muratori M; Ng AC; Cefalù C; Delgado V; Schalij MJ; Bax JJ; Marsan NA; Tamborini G; Pepi M Heart; 2012 Aug; 98(16):1229-36. PubMed ID: 22826560 [TBL] [Abstract][Full Text] [Related]
67. Multiplug paravalvular leak closure using Amplatzer Vascular Plugs III: A prospective registry. Smolka G; Pysz P; Jasiński M; Roleder T; Peszek-Przybyła E; Ochała A; Wojakowski W Catheter Cardiovasc Interv; 2016 Feb; 87(3):478-87. PubMed ID: 25963541 [TBL] [Abstract][Full Text] [Related]
68. Paravalvular Regurgitation After TAVR: A Doppler Dilemma. Little SH JACC Cardiovasc Imaging; 2015 Sep; 8(9):1004-1006. PubMed ID: 26381763 [No Abstract] [Full Text] [Related]
69. Association of Paravalvular Regurgitation With 1-Year Outcomes After Transcatheter Aortic Valve Replacement With the SAPIEN 3 Valve. Pibarot P; Hahn RT; Weissman NJ; Arsenault M; Beaudoin J; Bernier M; Dahou A; Khalique OK; Asch FM; Toubal O; Leipsic J; Blanke P; Zhang F; Parvataneni R; Alu M; Herrmann H; Makkar R; Mack M; Smalling R; Leon M; Thourani VH; Kodali S JAMA Cardiol; 2017 Nov; 2(11):1208-1216. PubMed ID: 28973091 [TBL] [Abstract][Full Text] [Related]
70. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation. Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Sieswerda G; Budde R; van der Linden M; Juthier F; Banfi C; Hurt C; Samim M; Hillaert M; van Herwerden L; Bertrand ME; Doevendans PA; Van Belle E J Thorac Cardiovasc Surg; 2013 Feb; 145(2):398-405. PubMed ID: 22377664 [TBL] [Abstract][Full Text] [Related]
71. Optimal imaging for guiding TAVR: transesophageal or transthoracic echocardiography, or just fluoroscopy? Kronzon I; Jelnin V; Ruiz CE; Saric M; Williams MR; Kasel AM; Shivaraju A; Colombo A; Kastrati A JACC Cardiovasc Imaging; 2015 Mar; 8(3):361-370. PubMed ID: 25772839 [No Abstract] [Full Text] [Related]
72. Impact of device landing zone calcification patterns on paravalvular regurgitation after transcatheter aortic valve replacement with different next-generation devices. Mauri V; Frohn T; Deuschl F; Mohemed K; Kuhr K; Reimann A; Körber MI; Schofer N; Adam M; Friedrichs K; Kuhn EW; Scholtz S; Rudolph V; Wahlers TCW; Baldus S; Mader N; Schäfer U; Rudolph TK Open Heart; 2020 May; 7(1):. PubMed ID: 32393655 [TBL] [Abstract][Full Text] [Related]
73. Imaging the future of transcatheter aortic valve replacement. Stewart WJ JACC Cardiovasc Imaging; 2008 Jan; 1(1):25-8. PubMed ID: 19356401 [No Abstract] [Full Text] [Related]
74. Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement. Hahn RT; Kodali S; Tuzcu EM; Leon MB; Kapadia S; Gopal D; Lerakis S; Lindman BR; Wang Z; Webb J; Thourani VH; Douglas PS JACC Cardiovasc Imaging; 2015 Mar; 8(3):288-318. PubMed ID: 25772835 [TBL] [Abstract][Full Text] [Related]
75. Use of cardiac CT angiography to assist in the diagnosis and treatment of aortic prosthetic paravalvular leak: a practical guide. Lesser JR; Han BK; Newell M; Schwartz RS; Pedersen W; Sorajja P J Cardiovasc Comput Tomogr; 2015; 9(3):159-64. PubMed ID: 25533224 [TBL] [Abstract][Full Text] [Related]
76. Severe intraprosthetic regurgitation and valve embolization after transcatheter aortic valve implantation. Ben-Dor I; Satler LF; Pichard AD; Waksman R Catheter Cardiovasc Interv; 2013 Feb; 81(2):392-6. PubMed ID: 22566389 [TBL] [Abstract][Full Text] [Related]
77. Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis. Barbanti M; Petronio AS; Capodanno D; Ettori F; Colombo A; Bedogni F; De Marco F; De Carlo M; Fiorina C; Latib A; Testa L; Bruschi G; Poli A; Giannini C; Curello S; Maffeo D; Sgroi C; Martina P; Gulino S; Patanè M; Ohno Y; Attizzani GF; Immè S; Cannata S; Gentili A; Rossi A; Tamburino C JACC Cardiovasc Interv; 2014 Sep; 7(9):1014-21. PubMed ID: 25234674 [TBL] [Abstract][Full Text] [Related]
78. Slope of left ventricular filling as an index of valvular and paravalvular regurgitation in native and prosthetic aortic valves. Makki N; Ghao X; Whitson B; Shreenivas S; Crestanello J; Lilly S Catheter Cardiovasc Interv; 2018 Dec; 92(7):1397-1403. PubMed ID: 30019828 [TBL] [Abstract][Full Text] [Related]
79. Aortic Regurgitation after TAVR: From Bad to Worse. Hiltrop N; Adriaenssens T; Herijgers P; Dubois C J Heart Valve Dis; 2016 Mar; 25(2):182-184. PubMed ID: 27989062 [TBL] [Abstract][Full Text] [Related]