254 related articles for article (PubMed ID: 25783228)
1. Three-dimensional black-blood T1-weighted turbo spin-echo techniques for the diagnosis of deep vein thrombosis in comparison with contrast-enhanced magnetic resonance imaging: a pilot study.
Treitl KM; Treitl M; Kooijman-Kurfuerst H; Kammer NN; Coppenrath E; Suderland E; Czihal M; Hoffmann U; Reiser MF; Saam T
Invest Radiol; 2015 Jun; 50(6):401-8. PubMed ID: 25783228
[TBL] [Abstract][Full Text] [Related]
2. Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences.
Park HJ; Lee SY; Park NH; Ahn JH; Chung EC; Kim SJ; Cha JG
Acta Radiol; 2016 Nov; 57(11):1372-1379. PubMed ID: 25585852
[TBL] [Abstract][Full Text] [Related]
3. Visualization of deep veins and detection of deep vein thrombosis (DVT) with balanced turbo field echo (b-TFE) and contrast-enhanced T1 fast field echo (CE-FFE) using a blood pool agent (BPA).
Enden T; Storås TH; Negård A; Haig Y; Sandvik L; Gjesdal KI; Sandset PM; Kløw NE
J Magn Reson Imaging; 2010 Feb; 31(2):416-24. PubMed ID: 20099355
[TBL] [Abstract][Full Text] [Related]
4. Performance of spin-echo and gradient-echo T1-weighted sequences for evaluation of dural venous sinus thrombosis and stenosis.
Saindane AM; Mitchell BC; Kang J; Desai NK; Dehkharghani S
AJR Am J Roentgenol; 2013 Jul; 201(1):162-9. PubMed ID: 23789671
[TBL] [Abstract][Full Text] [Related]
5. Fat-suppressed volume isotropic turbo spin echo acquisition (VISTA) MR imaging in evaluating radial and root tears of the meniscus: focusing on reader-defined axial reconstruction.
Lim D; Lee YH; Kim S; Song HT; Suh JS
Eur J Radiol; 2013 Dec; 82(12):2296-302. PubMed ID: 24074646
[TBL] [Abstract][Full Text] [Related]
6. 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.
Seo JM; Yoon YC; Kwon JW
Acta Radiol; 2011 Dec; 52(10):1119-24. PubMed ID: 22144425
[TBL] [Abstract][Full Text] [Related]
7. Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo.
Jung JY; Yoon YC; Jung JY; Choe BK
Acta Radiol; 2013 Apr; 54(3):284-91. PubMed ID: 23319720
[TBL] [Abstract][Full Text] [Related]
8. Clinical impact of 3-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 3-dimensional turbo-spin-echo magnetic resonance cholangiopancreatography.
Itatani R; Namimoto T; Takaoka H; Katahira K; Noda S; Toyonari N; Yamashita Y
J Comput Assist Tomogr; 2015; 39(1):19-24. PubMed ID: 25299796
[TBL] [Abstract][Full Text] [Related]
9. Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury.
Park HJ; Lee SY; Park NH; Rho MH; Chung EC; Park JH; Park SJ
Clin Radiol; 2016 Apr; 71(4):349-55. PubMed ID: 26774370
[TBL] [Abstract][Full Text] [Related]
10. Detection of brain metastases by 3-dimensional magnetic resonance imaging at 3 T: comparison between T1-weighted volume isotropic turbo spin echo acquisition and 3-dimensional T1-weighted fluid-attenuated inversion recovery imaging.
Yoshida A; Tha KK; Fujima N; Zaitsu Y; Yoshida D; Tsukahara A; Onodera S; Shirato H; Terae S
J Comput Assist Tomogr; 2013; 37(1):84-90. PubMed ID: 23321838
[TBL] [Abstract][Full Text] [Related]
11. Perirenal lymphatic systems: Evaluation using spectral presaturation with inversion recovery T2 -weighted MR images with 3D volume isotropic turbo spin-echo acquisition at 3.0T.
Matsumoto S; Mori H; Kiyonaga M; Yamada Y; Takaji R; Sato F; Mimata H; Hijiya N; Moriyama M; Tanoue R; Tomonari K; Matsumoto T; Hasebe T
J Magn Reson Imaging; 2016 Oct; 44(4):897-905. PubMed ID: 27008549
[TBL] [Abstract][Full Text] [Related]
12. Three-dimensional contrast-enhanced magnetic resonance venography for detection of renal vein thrombosis: comparison with multidetector CT venography.
Zhang LJ; Wu X; Yang GF; Tang CX; Luo S; Zhou CS; Ji XM; Lu GM
Acta Radiol; 2013 Dec; 54(10):1125-31. PubMed ID: 23794130
[TBL] [Abstract][Full Text] [Related]
13. Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence.
Cho HH; Choi YH; Cheon JE; Lee SM; Kim WS; Kim IO; Paek M
AJR Am J Roentgenol; 2016 Jul; 207(1):177-82. PubMed ID: 27070492
[TBL] [Abstract][Full Text] [Related]
14. Contrast-enhanced radial 3D fat-suppressed T1-weighted gradient-recalled echo sequence versus conventional fat-suppressed contrast-enhanced T1-weighted studies of the head and neck.
Wu X; Raz E; Block TK; Geppert C; Hagiwara M; Bruno MT; Fatterpekar GM
AJR Am J Roentgenol; 2014 Oct; 203(4):883-9. PubMed ID: 25247956
[TBL] [Abstract][Full Text] [Related]
15. Usefulness of dual echo volumetric isotropic turbo spin echo acquisition (VISTA) in MR imaging of the temporomandibular joint.
Sugimori Y; Tanaka S; Nishimura T; Yamamoto A; Ohfuji S; Naito Y; Katsumata Y; Miki Y
Magn Reson Med Sci; 2013 Dec; 12(4):249-59. PubMed ID: 24172791
[TBL] [Abstract][Full Text] [Related]
16. Abdominopelvic and lower extremity deep venous thrombosis: evaluation with contrast-enhanced MR venography with a blood-pool agent.
Huang SY; Kim CY; Miller MJ; Gupta RT; Lessne ML; Horvath JJ; Boll DT; Evans PD; Befera NT; Krishnan P; Chan JL; Merkle EM
AJR Am J Roentgenol; 2013 Jul; 201(1):208-14. PubMed ID: 23789677
[TBL] [Abstract][Full Text] [Related]
17. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.
Lee S; Jee WH; Jung JY; Lee SY; Ryu KS; Ha KY
Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584
[TBL] [Abstract][Full Text] [Related]
18. Clinical value of fat-suppressed 3D volume isotropic spin-echo (VISTA) sequence compared to 2D sequence in evaluating internal structures of the knee.
Lim D; Han Lee Y; Kim S; Song HT; Suh JS
Acta Radiol; 2016 Jan; 57(1):66-73. PubMed ID: 25585850
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional magnetic resonance observation of cartilage repair tissue (MOCART) score assessed with an isotropic three-dimensional true fast imaging with steady-state precession sequence at 3.0 Tesla.
Welsch GH; Zak L; Mamisch TC; Resinger C; Marlovits S; Trattnig S
Invest Radiol; 2009 Sep; 44(9):603-12. PubMed ID: 19692843
[TBL] [Abstract][Full Text] [Related]
20. Magnetic resonance imaging and ultrasonography in diagnosis of pelvic vein thrombosis during pregnancy.
Torkzad MR; Bremme K; Hellgren M; Eriksson MJ; Hagman A; Jörgensen T; Lund K; Sandgren G; Blomqvist L; Kälebo P
Thromb Res; 2010 Aug; 126(2):107-12. PubMed ID: 20627280
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]