These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 25784316)

  • 1. Study of the effect of altitude on the measurement of glycated haemoglobin using point-of-care instruments.
    Veigne SW; Sobngwi E; Nouthe BE; Sobngwi-Tambekou J; Balti EV; Limen S; Dehayem MY; Ama V; Nguewa J; Ndour-Mbaye M; Camara A; Balde NM; Mbanya J
    Cardiovasc J Afr; 2015; 26(1):38-40. PubMed ID: 25784316
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HbA
    Kenealy T; Herd G; Musaad S; Wells S
    Prim Care Diabetes; 2019 Apr; 13(2):170-175. PubMed ID: 30545795
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Good correlation between the Afinion AS100 analyser and the ABX Pentra 400 analyser for the measurement of glycosylated haemoglobin and lipid levels in older adults in Durban, South Africa.
    Abbai NS; Nyirenda M; Reddy T; Ramjee G
    S Afr Med J; 2017 Dec; 108(1):50-55. PubMed ID: 29262979
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon.
    Saxton AT; Miranda JJ; Ortiz EJ; Pan W
    Ann Glob Health; 2018 Nov; 84(4):618-624. PubMed ID: 30779508
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy and Precision of a Point-of-Care HbA1c Test.
    Arnold WD; Kupfer K; Little RR; Amar M; Horowitz B; Godbole N; Hvidsten Swensen M; Li Y; San George RC
    J Diabetes Sci Technol; 2020 Sep; 14(5):883-889. PubMed ID: 30854894
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of point-of-care and over-the-counter testing methods for hemoglobin A1c: how good do they need to be?
    Little RR
    J Diabetes Sci Technol; 2010 Nov; 4(6):1504-6. PubMed ID: 21129347
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Point-of-care testing improves diabetes management in a primary care clinic in South Africa.
    Motta LA; Shephard MDS; Brink J; Lawson S; Rheeder P
    Prim Care Diabetes; 2017 Jun; 11(3):248-253. PubMed ID: 28161128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test.
    Arnold WD; Kupfer K; Hvidsten Swensen M; Fortner KS; Bays HE; Davis M; Klaff LJ; San George RC
    J Diabetes Sci Technol; 2020 Sep; 14(5):890-895. PubMed ID: 30841743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of IFCC-calibrated HbA(1c) from laboratory and point of care testing systems.
    Manley SE; Hikin LJ; Round RA; Manning PW; Luzio SD; Dunseath GJ; Nightingale PG; Stratton IM; Cramb R; Sikaris KA; Gough SC; Webber J
    Diabetes Res Clin Pract; 2014 Sep; 105(3):364-72. PubMed ID: 24985893
    [TBL] [Abstract][Full Text] [Related]  

  • 10. HbA
    Dubach IL; Christ ER; Diem P
    Prim Care Diabetes; 2019 Dec; 13(6):583-587. PubMed ID: 31175054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of point-of-care HbA1c testing in pregnant women.
    Culliney K; McCowan LME; Okesene-Gafa K; Murphy R; Rowan J; Taylor RS; Mckinlay CJD;
    Aust N Z J Obstet Gynaecol; 2018 Dec; 58(6):643-647. PubMed ID: 29468638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implementation of POCT in the diabetic clinic in a large hospital.
    Tanyanyiwa D; Dandara C; Bhana SA; Pauly B; Marule F; Ramokoka M; Bwititi P; Nwose U; Nkosi B
    Afr Health Sci; 2015 Sep; 15(3):902-7. PubMed ID: 26957980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Point of care HbA
    Huangfu P; Laurence YV; Alisjahbana B; Ugarte-Gil C; Riza AL; Walzl G; Ruslami R; Moore DAJ; Ioana M; McAllister S; Ronacher K; Koesoemadinata RC; Grint D; Kerry S; Coronel J; Malherbe ST; Griffiths U; Dockrell HM; Hill PC; van Crevel R; Pearson F; Critchley JA
    Int J Tuberc Lung Dis; 2019 Mar; 23(3):283-292. PubMed ID: 30871659
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the accuracy of two point-of-care haemoglobin meters used in sub-Saharan African population: a cross-sectional study.
    Choukem SP; Sih C; Ntumsi AT; Dimala CA; Mboue-Djieka Y; Ngouadjeu EDT; Kengne AP
    BMC Cardiovasc Disord; 2020 Mar; 20(1):111. PubMed ID: 32138653
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Erythrocytosis and Performance of HbA1c in Detecting Diabetes on an Oxygen-Deficient Plateau: A Population-based Study.
    Ren Q; Lv X; Yang L; Yue J; Luo Y; Zhou L; Meng S; Yang S; Puchi B; Zhou X; Ji L
    J Clin Endocrinol Metab; 2020 Apr; 105(4):. PubMed ID: 31904080
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Point-of-care hemoglobin A1c testing in postmortem examination.
    Na JY
    Forensic Sci Med Pathol; 2018 Sep; 14(3):322-326. PubMed ID: 29696506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Verification of a novel point-of-care HbA
    Wang Y; Peng W; Tang J; Dong L; Gu C; Zhang X; Zhou J; Jia W
    Biochem Med (Zagreb); 2018 Jun; 28(2):020705. PubMed ID: 29666558
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Boronate Affinity Chromatography Accurately Measures HbA1c also in Patients with End-Stage Renal Disease - Performance Evaluation of the A1c HPLC Analyzer.
    Slowinska-Solnica K; Pawlica-Gosiewska D; Gawlik K; Kuzniewski M; Maziarz B; Solnica B
    Clin Lab; 2018 Sep; 64(9):1451-1455. PubMed ID: 30274022
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of glycated albumin and glycosylated hemoglobin for the screening of diabetes mellitus in Taiwan.
    Hsu P; Ai M; Kanda E; Yu NC; Chen HL; Chen HW; Cheng MH; Kohzuma T; Schaefer EJ; Yoshida M
    Atherosclerosis; 2015 Sep; 242(1):327-33. PubMed ID: 26247684
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Glycated haemoglobin: what is the diagnostic yield at shortened testing intervals?
    Loh TP; Tan KM; Saw S; Sethi SK
    Diabetes Res Clin Pract; 2011 Nov; 94(2):e40-2. PubMed ID: 21840616
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.