264 related articles for article (PubMed ID: 25785960)
1. Analysis of the Fracture Mechanism of Ti-6Al-4V Alloy Rods That Failed Clinically After Spinal Instrumentation Surgery.
Yamanaka K; Mori M; Yamazaki K; Kumagai R; Doita M; Chiba A
Spine (Phila Pa 1976); 2015 Jul; 40(13):E767-73. PubMed ID: 25785960
[TBL] [Abstract][Full Text] [Related]
2. Thermomechanical effects of spine surgery rods composed of different metals and alloys.
Noshchenko A; Patel VV; Baldini T; Yun L; Lindley EM; Burger EL
Spine (Phila Pa 1976); 2011 May; 36(11):870-8. PubMed ID: 20739915
[TBL] [Abstract][Full Text] [Related]
3. Comparison between 4.0-mm stainless steel and 4.75-mm titanium alloy single-rod spinal instrumentation for anterior thoracoscopic scoliosis surgery.
Yoon SH; Ugrinow VL; Upasani VV; Pawelek JB; Newton PO
Spine (Phila Pa 1976); 2008 Sep; 33(20):2173-8. PubMed ID: 18794758
[TBL] [Abstract][Full Text] [Related]
4. Spine rod straightening as a possible cause for revision.
Ayers R; Hayne M; Burger E
J Mater Sci Mater Med; 2017 Aug; 28(8):123. PubMed ID: 28698941
[TBL] [Abstract][Full Text] [Related]
5. An initial study of diffusion bonds between superplastic Ti-6Al-4V for implant dentistry applications.
Elias KL; Daehn GS; Brantley WA; McGlumphy EA
J Prosthet Dent; 2007 Jun; 97(6):357-65. PubMed ID: 17618918
[TBL] [Abstract][Full Text] [Related]
6. Fracture mechanisms in Ti and Co-Cr growing rods and impact on clinical practice.
Ribesse A; Ismail K; Croonenborghs M; Irda N; Miladi L; Jacques PJ; Mousny M; Pardoen T
J Mech Behav Biomed Mater; 2021 Sep; 121():104620. PubMed ID: 34119814
[TBL] [Abstract][Full Text] [Related]
7. Mechanical performance of the new posterior spinal implant: effect of materials, connecting plate, and pedicle screw design.
Chen PQ; Lin SJ; Wu SS; So H
Spine (Phila Pa 1976); 2003 May; 28(9):881-6; discussion 887. PubMed ID: 12942002
[TBL] [Abstract][Full Text] [Related]
8. Implant Failure of Titanium Versus Cobalt-Chromium Growing Rods in Early-onset Scoliosis.
Shinohara K; Takigawa T; Tanaka M; Sugimoto Y; Arataki S; Yamane K; Watanabe N; Ozaki T; Sarai T
Spine (Phila Pa 1976); 2016 Mar; 41(6):502-7. PubMed ID: 26966974
[TBL] [Abstract][Full Text] [Related]
9. Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining.
Contreras EF; Henriques GE; Giolo SR; Nobilo MA
J Prosthet Dent; 2002 Nov; 88(5):467-72. PubMed ID: 12473994
[TBL] [Abstract][Full Text] [Related]
10. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols.
Guilherme AS; Henriques GE; Zavanelli RA; Mesquita MF
J Prosthet Dent; 2005 Apr; 93(4):378-85. PubMed ID: 15798689
[TBL] [Abstract][Full Text] [Related]
11. Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy.
Cook SD; Georgette FS; Skinner HB; Haddad RJ
J Biomed Mater Res; 1984; 18(5):497-512. PubMed ID: 6736080
[TBL] [Abstract][Full Text] [Related]
12. Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants.
Dick JC; Bourgeault CA
Spine (Phila Pa 1976); 2001 Aug; 26(15):1668-72. PubMed ID: 11474353
[TBL] [Abstract][Full Text] [Related]
13. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
[TBL] [Abstract][Full Text] [Related]
14. Fatigue strength reduction of Ti-6Al-4V titanium alloy after contact with high-frequency cauterising instruments.
Zobel SM; Morlock MM; Huber G
Med Eng Phys; 2020 Jul; 81():58-67. PubMed ID: 32513523
[TBL] [Abstract][Full Text] [Related]
15. Mechanical Analysis of Notch-Free Pre-Bent Rods for Spinal Deformity Surgery.
Yamada K; Sudo H; Iwasaki N; Chiba A
Spine (Phila Pa 1976); 2020 Mar; 45(6):E312-E318. PubMed ID: 31574057
[TBL] [Abstract][Full Text] [Related]
16. [Superplastic forming of titanium alloy denture base].
Okuno O; Nakano T; Hamanaka H; Miura I; Ito M; Ai M; Okada M
Shika Zairyo Kikai; 1989 Mar; 8(2):129-36. PubMed ID: 2603084
[TBL] [Abstract][Full Text] [Related]
17. Mechanical properties of cast Ti-6Al-4V-XCu alloys.
Aoki T; Okafor IC; Watanabe I; Hattori M; Oda Y; Okabe T
J Oral Rehabil; 2004 Nov; 31(11):1109-14. PubMed ID: 15525390
[TBL] [Abstract][Full Text] [Related]
18. The effect of post-sintering heat treatments on the fatigue properties of porous coated Ti-6Al-4V alloy.
Cook SD; Thongpreda N; Anderson RC; Haddad RJ
J Biomed Mater Res; 1988 Apr; 22(4):287-302. PubMed ID: 3372550
[TBL] [Abstract][Full Text] [Related]
19. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus.
Miura K; Yamada N; Hanada S; Jung TK; Itoi E
Acta Biomater; 2011 May; 7(5):2320-6. PubMed ID: 21316491
[TBL] [Abstract][Full Text] [Related]
20. [Titanium as an implant material for rods of transpedicular instrumentation of the lumbar spine].
von Knoch M; Saxler G; Quint U
Biomed Tech (Berl); 2004 May; 49(5):132-6. PubMed ID: 15212198
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]