279 related articles for article (PubMed ID: 25786930)
1. Enhanced correlation between quantitative ultrasound and structural and mechanical properties of bone using combined transmission-reflection measurement. Lin L; Lin W; Qin YX J Acoust Soc Am; 2015 Mar; 137(3):1144-52. PubMed ID: 25786930 [TBL] [Abstract][Full Text] [Related]
2. Influence of density, elasticity, and structure on ultrasound transmission through trabecular bone cylinders. Cavani F; Giavaresi G; Fini M; Bertoni L; de Terlizzi F; Barkmann R; Cane V IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1465-72. PubMed ID: 18986935 [TBL] [Abstract][Full Text] [Related]
3. Bone volume fraction and structural parameters for estimation of mechanical stiffness and failure load of human cancellous bone samples; in-vitro comparison of ultrasound transit time spectroscopy and X-ray μCT. Alomari AH; Wille ML; Langton CM Bone; 2018 Feb; 107():145-153. PubMed ID: 29198979 [TBL] [Abstract][Full Text] [Related]
4. High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties. Majumdar S; Kothari M; Augat P; Newitt DC; Link TM; Lin JC; Lang T; Lu Y; Genant HK Bone; 1998 May; 22(5):445-54. PubMed ID: 9600777 [TBL] [Abstract][Full Text] [Related]
5. Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a 3D model simulation. Haïat G; Padilla F; Peyrin F; Laugier P J Bone Miner Res; 2007 May; 22(5):665-74. PubMed ID: 17295606 [TBL] [Abstract][Full Text] [Related]
6. Principal trabecular structural orientation predicted by quantitative ultrasound is strongly correlated with μFEA determined anisotropic apparent stiffness. Lin L; Oon HY; Lin W; Qin YX Biomech Model Mechanobiol; 2014 Oct; 13(5):961-71. PubMed ID: 24419558 [TBL] [Abstract][Full Text] [Related]
7. Relationships of trabecular bone structure with quantitative ultrasound parameters: in vitro study on human proximal femur using transmission and backscatter measurements. Padilla F; Jenson F; Bousson V; Peyrin F; Laugier P Bone; 2008 Jun; 42(6):1193-202. PubMed ID: 18396124 [TBL] [Abstract][Full Text] [Related]
8. Prediction of density and mechanical properties of human trabecular bone in vitro by using ultrasound transmission and backscattering measurements at 0.2-6.7 MHz frequency range. Hakulinen MA; Day JS; Töyräs J; Timonen M; Kröger H; Weinans H; Kiviranta I; Jurvelin JS Phys Med Biol; 2005 Apr; 50(8):1629-42. PubMed ID: 15815086 [TBL] [Abstract][Full Text] [Related]
9. In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radius. Newitt DC; Majumdar S; van Rietbergen B; von Ingersleben G; Harris ST; Genant HK; Chesnut C; Garnero P; MacDonald B Osteoporos Int; 2002 Jan; 13(1):6-17. PubMed ID: 11878456 [TBL] [Abstract][Full Text] [Related]
10. Of mice, rats and men: trabecular bone architecture in mammals scales to body mass with negative allometry. Barak MM; Lieberman DE; Hublin JJ J Struct Biol; 2013 Aug; 183(2):123-31. PubMed ID: 23639903 [TBL] [Abstract][Full Text] [Related]
11. Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular bone. Mittra E; Rubin C; Qin YX J Biomech; 2005 Jun; 38(6):1229-37. PubMed ID: 15863107 [TBL] [Abstract][Full Text] [Related]
12. Is quantitative ultrasound dependent on bone structure? A reflection. Njeh CF; Fuerst T; Diessel E; Genant HK Osteoporos Int; 2001; 12(1):1-15. PubMed ID: 11305077 [TBL] [Abstract][Full Text] [Related]
13. Characterization of the trabecular bone structure using frequency modulated ultrasound pulse. Lin W; Xia Y; Qin YX J Acoust Soc Am; 2009 Jun; 125(6):4071-7. PubMed ID: 19507988 [TBL] [Abstract][Full Text] [Related]
14. Quantitative ultrasound and trabecular architecture in the human calcaneus. Nicholson PH; Müller R; Cheng XG; Rüegsegger P; Van Der Perre G; Dequeker J; Boonen S J Bone Miner Res; 2001 Oct; 16(10):1886-92. PubMed ID: 11585354 [TBL] [Abstract][Full Text] [Related]
15. The quantification of 3D-trabecular architecture of the fourth cervical vertebra using CT osteoabsorptiometry and micro-CT. Poilliot A; Gay-Dujak MH; Müller-Gerbl M J Orthop Surg Res; 2023 Apr; 18(1):297. PubMed ID: 37046305 [TBL] [Abstract][Full Text] [Related]
16. Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur. Wachter NJ; Augat P; Mentzel M; Sarkar MR; Krischak GD; Kinzl L; Claes LE Bone; 2001 Jan; 28(1):133-9. PubMed ID: 11165955 [TBL] [Abstract][Full Text] [Related]
17. Prediction of trabecular bone principal structural orientation using quantitative ultrasound scanning. Lin L; Cheng J; Lin W; Qin YX J Biomech; 2012 Jun; 45(10):1790-5. PubMed ID: 22560370 [TBL] [Abstract][Full Text] [Related]
18. Comparison of synchrotron radiation and conventional x-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Chappard C; Basillais A; Benhamou L; Bonassie A; Brunet-Imbault B; Bonnet N; Peyrin F Med Phys; 2006 Sep; 33(9):3568-77. PubMed ID: 17022253 [TBL] [Abstract][Full Text] [Related]
19. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Ulrich D; van Rietbergen B; Laib A; Rüegsegger P Bone; 1999 Jul; 25(1):55-60. PubMed ID: 10423022 [TBL] [Abstract][Full Text] [Related]
20. Quantitative ultrasound of the calcaneus reflects the mechanical properties of calcaneal trabecular bone. Bouxsein ML; Radloff SE J Bone Miner Res; 1997 May; 12(5):839-46. PubMed ID: 9144351 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]