These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 25791061)

  • 21. A novel algorithm to predict the QT interval during intrinsic atrioventricular conduction from an electrocardiogram obtained during ventricular pacing.
    Sriwattanakomen R; Mukamal KJ; Shvilkin A
    Heart Rhythm; 2016 Oct; 13(10):2076-82. PubMed ID: 27369873
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Native QRS complex duration predicts paced QRS width in patients with normal left ventricular function and right ventricular pacing for atrioventricular block.
    Pap R; Fürge P; Bencsik G; Makai A; Sághy L; Forster T
    J Electrocardiol; 2007 Oct; 40(4):360-4. PubMed ID: 17254598
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The relationship of bipolar left ventricular pacing stimulus intensity to cardiac depolarization and repolarization in humans with cardiac resynchronization devices.
    Theis C; Bavikati VV; Langberg JJ; Lloyd MS
    J Cardiovasc Electrophysiol; 2009 Jun; 20(6):645-9. PubMed ID: 19207760
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction.
    Sweeney MO; Hellkamp AS; Ellenbogen KA; Greenspon AJ; Freedman RA; Lee KL; Lamas GA;
    Circulation; 2003 Jun; 107(23):2932-7. PubMed ID: 12782566
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dynamic ventricular overdrive stimulation in atrial fibrillation: effects on ventricular rate irregularity, ventricular pacing, and fusion beats.
    Nölker G; Gutleben KJ; Asbach S; Ritscher G; Marschang H; Sinha AM; Boileau P; Benser ME; Hallier B; Hümmer A; Brachmann J
    Europace; 2011 Dec; 13(12):1688-94. PubMed ID: 21784744
    [TBL] [Abstract][Full Text] [Related]  

  • 26. QT correction across the heart rate spectrum, in atrial fibrillation and ventricular conduction defects.
    Vandenberk B; Vandael E; Robyns T; Vandenberghe J; Garweg C; Foulon V; Ector J; Willems R
    Pacing Clin Electrophysiol; 2018 Sep; 41(9):1101-1108. PubMed ID: 29928779
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Heart failure during cardiac pacing.
    Sweeney MO; Hellkamp AS
    Circulation; 2006 May; 113(17):2082-8. PubMed ID: 16636167
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Minimizing ventricular pacing by a novel atrioventricular (AV) delay hysteresis algorithm in patients with intact or compromised intrinsic AV conduction and different atrial and ventricular lead locations.
    Pakarinen S; Toivonen L
    Ann Med; 2013 Sep; 45(5-6):438-45. PubMed ID: 23768003
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Optimal sensed atrio-ventricular interval determined by paced QRS morphology.
    Van Gelder BM; Bracke FA; Van Der Voort PH; Meijer A
    Pacing Clin Electrophysiol; 2007 Apr; 30(4):476-81. PubMed ID: 17437570
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biventricular pacing has an advantage over left ventricular epicardial pacing alone to minimize proarrhythmic perturbation of repolarization.
    Harada M; Osaka T; Yokoyama E; Takemoto Y; Ito A; Kodama I
    J Cardiovasc Electrophysiol; 2006 Feb; 17(2):151-6. PubMed ID: 16533252
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison and Validation of Recommended QT Interval Correction Formulas for Predicting Cardiac Arrhythmias in Patients With Advanced Heart Failure and Cardiac Resynchronization Devices.
    Iglesias-Álvarez D; Rodríguez-Mañero M; García-Seara FJ; Kreidieh O; Martínez-Sande JL; Álvarez-Álvarez B; Fernández-López XA; González-Melchor L; Lage-Fernández R; Moscoso-Galán I; González-Juanatey JR
    Am J Cardiol; 2017 Sep; 120(6):959-965. PubMed ID: 28739032
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prolonged QT interval diagnosis suppression by a widely used computerized ECG analysis system.
    Garg A; Lehmann MH
    Circ Arrhythm Electrophysiol; 2013 Feb; 6(1):76-83. PubMed ID: 23275261
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ventricular Effective Refraction Period and Ventricular Repolarization Analysis in Experimental Tachycardiomyopathy in Swine.
    Noszczyk-Nowak A; Pasławska U; Gajek J; Janiszewski A; Pasławski R; Zyśko D; Nicpoń J
    Adv Clin Exp Med; 2016; 25(3):409-14. PubMed ID: 27629727
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Variations in QRS duration and axis with different sites and intervals of right ventricular pacing].
    Mascia F; Fattore L; Viscusi M; Golino P; Di Donna V; Ricciardiello V
    Ital Heart J Suppl; 2002 Nov; 3(11):1106-11. PubMed ID: 12506512
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials.
    Wilkoff BL;
    Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Diurnal pattern of QTc interval: how long is prolonged? Possible relation to circadian triggers of cardiovascular events.
    Molnar J; Zhang F; Weiss J; Ehlert FA; Rosenthal JE
    J Am Coll Cardiol; 1996 Jan; 27(1):76-83. PubMed ID: 8522713
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ventricular activation sequence during left ventricular pacing promotes QRS complex oversensing in the atrial channel.
    Jastrzebski M
    Pacing Clin Electrophysiol; 2011 Dec; 34(12):1682-6. PubMed ID: 21954967
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biventricular pacing improves the blunted force-frequency relation present during univentricular pacing in patients with heart failure and conduction delay.
    Vollmann D; Lüthje L; Schott P; Hasenfuss G; Unterberg-Buchwald C
    Circulation; 2006 Feb; 113(7):953-9. PubMed ID: 16476849
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Paced QRS morphology for confirming septal pacemaker lead implantation: correction of a misconception.
    Burri H
    Europace; 2010 Dec; 12(12):1660-1. PubMed ID: 20974760
    [No Abstract]   [Full Text] [Related]  

  • 40. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.