193 related articles for article (PubMed ID: 25794751)
21. Construction of a triglyceride amperometric biosensor based on chitosan-ZnO nanocomposite film.
Narang J; Pundir CS
Int J Biol Macromol; 2011 Nov; 49(4):707-15. PubMed ID: 21763341
[TBL] [Abstract][Full Text] [Related]
22. Preparing a new biosensor for hypoxanthine determination by immobilization of xanthine oxidase and uricase in polypyrrole-polyvinyl sulphonate film.
Görgülü M; Çete S; Arslan H; Yaşar A
Artif Cells Nanomed Biotechnol; 2013 Oct; 41(5):327-31. PubMed ID: 23305069
[TBL] [Abstract][Full Text] [Related]
23. Supramolecular immobilization of xanthine oxidase on electropolymerized matrix of functionalized hybrid gold nanoparticles/single-walled carbon nanotubes for the preparation of electrochemical biosensors.
Villalonga R; Díez P; Eguílaz M; Martínez P; Pingarrón JM
ACS Appl Mater Interfaces; 2012 Aug; 4(8):4312-9. PubMed ID: 22801986
[TBL] [Abstract][Full Text] [Related]
24. Immobilization of a trienzymatic system in a sol-gel matrix: a new fluorescent biosensor for xanthine.
Salinas-Castillo A; Pastor I; Mallavia R; Mateo CR
Biosens Bioelectron; 2008 Dec; 24(4):1059-62. PubMed ID: 18789677
[TBL] [Abstract][Full Text] [Related]
25. Construction of an amperometric TG biosensor based on AuPPy nanocomposite and poly (indole-5-carboxylic acid) modified Au electrode.
Narang J; Chauhan N; Rani P; Pundir CS
Bioprocess Biosyst Eng; 2013 Apr; 36(4):425-32. PubMed ID: 22903594
[TBL] [Abstract][Full Text] [Related]
26. Fabrication of an amperometric sarcosine biosensor based on sarcosine oxidase/chitosan/CuNPs/c-MWCNT/Au electrode for detection of prostate cancer.
Narwal V; Kumar P; Joon P; Pundir CS
Enzyme Microb Technol; 2018 Jun; 113():44-51. PubMed ID: 29602386
[TBL] [Abstract][Full Text] [Related]
27. Amperometric biosensor based on prussian blue and nafion modified screen-printed electrode for screening of potential xanthine oxidase inhibitors from medicinal plants.
El Harrad L; Amine A
Enzyme Microb Technol; 2016 Apr; 85():57-63. PubMed ID: 26920482
[TBL] [Abstract][Full Text] [Related]
28. Fabrication of a modified electrode based on Fe(3)O(4)NPs/MWCNT nanocomposite: application to simultaneous determination of guanine and adenine in DNA.
Shahrokhian S; Rastgar S; Amini MK; Adeli M
Bioelectrochemistry; 2012 Aug; 86():78-86. PubMed ID: 22421348
[TBL] [Abstract][Full Text] [Related]
29. A nanoceria-platinum-graphene nanocomposite for electrochemical biosensing.
Chaturvedi P; Vanegas DC; Taguchi M; Burrs SL; Sharma P; McLamore ES
Biosens Bioelectron; 2014 Aug; 58():179-85. PubMed ID: 24637166
[TBL] [Abstract][Full Text] [Related]
30. Development of tyrosinase biosensor based on quantum dots/chitosan nanocomposite for detection of phenolic compounds.
Han E; Yang Y; He Z; Cai J; Zhang X; Dong X
Anal Biochem; 2015 Oct; 486():102-6. PubMed ID: 26159737
[TBL] [Abstract][Full Text] [Related]
31. A high performance nanocomposite based bioanode for biofuel cell and biosensor application.
Li N; Sakamoto H; Takamura E; Zheng H; Suye SI
Anal Biochem; 2021 Oct; 631():114363. PubMed ID: 34478705
[TBL] [Abstract][Full Text] [Related]
32. A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode.
Naderi Asrami P; Mozaffari SA; Saber Tehrani M; Aberoomand Azar P
Int J Biol Macromol; 2018 Oct; 118(Pt A):649-660. PubMed ID: 29859844
[TBL] [Abstract][Full Text] [Related]
33. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode.
Li J; Lin X
Biosens Bioelectron; 2007 Jun; 22(12):2898-905. PubMed ID: 17215117
[TBL] [Abstract][Full Text] [Related]
34. An amperometric β-glucan biosensor based on the immobilization of bi-enzyme on Prussian blue-chitosan and gold nanoparticles-chitosan nanocomposite films.
Wang B; Ji X; Zhao H; Wang N; Li X; Ni R; Liu Y
Biosens Bioelectron; 2014 May; 55():113-9. PubMed ID: 24368228
[TBL] [Abstract][Full Text] [Related]
35. Biocompatible phosphonic acid-functionalized silica nanoparticles for sensitive detection of hypoxanthine in real samples.
Liu M; Chen S; Zhao X; Ye Y; Li J; Zhu Q; Zhao B; Zhao W; Huang X; Shen J
Talanta; 2013 Dec; 117():536-42. PubMed ID: 24209378
[TBL] [Abstract][Full Text] [Related]
36. L-amino acid biosensor based on L-amino acid oxidase immobilized onto NiHCNFe/c-MWCNT/PPy/GC electrode.
Lata S; Pundir CS
Int J Biol Macromol; 2013 Mar; 54():250-7. PubMed ID: 23237796
[TBL] [Abstract][Full Text] [Related]
37. Construction of an amperometric glucose biosensor based on the immobilization of glucose oxidase onto electrodeposited Pt nanoparticles-chitosan composite film.
Li J; Yuan R; Chai Y; Che X; Li W
Bioprocess Biosyst Eng; 2012 Sep; 35(7):1089-95. PubMed ID: 22311274
[TBL] [Abstract][Full Text] [Related]
38. Amperometric biosensor for xanthine with supramolecular architecture.
Villalonga R; Camacho C; Cao R; Hernández J; Matías JC
Chem Commun (Camb); 2007 Mar; (9):942-4. PubMed ID: 17311128
[TBL] [Abstract][Full Text] [Related]
39. Development of glucose biosensor based on reconstitution of glucose oxidase onto polymeric redox mediator coated pencil graphite electrodes.
Dervisevic M; Cevik E; Senel M
Enzyme Microb Technol; 2015 Jan; 68():69-76. PubMed ID: 25435508
[TBL] [Abstract][Full Text] [Related]
40. Fabrication of multiwalled carbon nanotube-polyaniline/platinum nanocomposite films toward improved performance for a cholesterol amperometric biosensor.
Xu Z; Cheng X; Tan J; Gan X
Biotechnol Appl Biochem; 2016 Nov; 63(6):757-764. PubMed ID: 27992074
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]