These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

352 related articles for article (PubMed ID: 25799717)

  • 21. Use of balloon expandable transcatheter valves for valve-in-valve implantation in patients with degenerative stentless aortic bioprostheses: Technical considerations and results.
    Bapat V; Davies W; Attia R; Hancock J; Bolter K; Young C; Redwood S; Thomas M
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):917-22; discussion 922-4. PubMed ID: 25037622
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical outcomes after implantation of a sutureless aortic bioprosthesis with concomitant mitral valve surgery: the SURE-AVR registry.
    Baghai M; Glauber M; Fontaine R; Castillo JC; Walker AH; Livi U; Montiel J; Royse A; Bisleri G; Pacini D; Argano V; Roumy A; Asimakopoulos G; Solinas M;
    J Cardiothorac Surg; 2021 May; 16(1):154. PubMed ID: 34053453
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Valve-in-valve hemodynamics of 20-mm transcatheter aortic valves in small bioprostheses.
    Azadani AN; Jaussaud N; Ge L; Chitsaz S; Chuter TA; Tseng EE
    Ann Thorac Surg; 2011 Aug; 92(2):548-55. PubMed ID: 21704287
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis.
    Martens S; Sadowski J; Eckstein FS; Bartus K; Kapelak B; Sievers HH; Schlensak C; Carrel T
    Eur J Cardiothorac Surg; 2011 Sep; 40(3):749-55. PubMed ID: 21342776
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Sutureless aortic valve bioprothesis '3F/ATS Enable'--4.5 years of a single-centre experience.
    Sadowski J; Kapelak B; Pfitzner R; Bartuś K
    Kardiol Pol; 2009 Aug; 67(8A):956-63. PubMed ID: 19784899
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access.
    Greif M; Lange P; Mair H; Becker C; Schmitz C; Steinbeck G; Kupatt C
    Clin Res Cardiol; 2012 Dec; 101(12):993-1001. PubMed ID: 22729757
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.
    Walther T; Falk V; Dewey T; Kempfert J; Emrich F; Pfannmüller B; Bröske P; Borger MA; Schuler G; Mack M; Mohr FW
    J Am Coll Cardiol; 2007 Jul; 50(1):56-60. PubMed ID: 17601546
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Valve-in-Valve Implantation Using the ACURATE Neo in Degenerated Aortic Bioprostheses: An International Multicenter Analysis.
    Holzamer A; Kim WK; Rück A; Sathananthan J; Keller L; Cosma J; Bauer T; Nef H; Amat-Santos IJ; Brinkert M; Husser O; Pellegrini C; Schofer J; Nerla R; Montorfano M; Giannini F; Stella P; Kuwata S; Hilker M; Castriota F; Ussia GP; Webb JG; Nietlispach F; Toggweiler S
    JACC Cardiovasc Interv; 2019 Nov; 12(22):2309-2316. PubMed ID: 31753302
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts.
    Kempfert J; Van Linden A; Linke A; Borger MA; Rastan A; Mukherjee C; Ender J; Schuler G; Mohr FW; Walther T
    Ann Thorac Surg; 2010 Jun; 89(6):1934-41. PubMed ID: 20494052
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sutureless Medtronic 3f Enable aortic valve replacement in a heavily calcified aortic root.
    Vola M; Fuzellier JF; Kasra A; Morel J; Campisi S; Ruggeri G; Favre JP
    J Heart Valve Dis; 2013 May; 22(3):436-8. PubMed ID: 24151774
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis.
    Gozdek M; Raffa GM; Suwalski P; Kolodziejczak M; Anisimowicz L; Kubica J; Navarese EP; Kowalewski M;
    Eur J Cardiothorac Surg; 2018 Mar; 53(3):495-504. PubMed ID: 29029105
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
    Bapat V; Attia R; Redwood S; Hancock J; Wilson K; Young C; Thomas M
    J Thorac Cardiovasc Surg; 2012 Dec; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Robotic total endoscopic sutureless aortic valve replacement: proof of concept for a future surgical setting.
    Vola M; Maureira P; Kassir R; Fuzellier JF; Campisi S; Doguet F; Albertini JN; Ruggieri VG; Folliguet T
    Int J Med Robot; 2016 Sep; 12(3):370-4. PubMed ID: 26282961
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Short- and mid-term safety and effectiveness of transcatheter aortic valve implantation in a failing surgical aortic bioprosthesis.
    Ong SH; Bauernschmitt R; Schuler G; Mueller R
    Eur J Cardiothorac Surg; 2012 Aug; 42(2):268-76; discussion 276. PubMed ID: 22334629
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Minimally invasive transapical aortic valve-in-a-valve implantation for severe aortic regurgitation in a degenerated stentless bioprosthesis.
    Kelpis TG; Mezilis NE; Ninios VN; Pitsis AA
    J Thorac Cardiovasc Surg; 2009 Oct; 138(4):1018-20. PubMed ID: 19660270
    [No Abstract]   [Full Text] [Related]  

  • 36. Reoperative surgery for degenerated aortic bioprostheses: predictors for emergency surgery and reoperative mortality.
    Vogt PR; Brunner-LaRocca H; Sidler P; Zünd G; Truniger K; Lachat M; Turina J; Turina MI
    Eur J Cardiothorac Surg; 2000 Feb; 17(2):134-9. PubMed ID: 10731648
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sutureless aortic valve replacement: a Canadian multicentre study.
    Mazine A; Teoh K; Bouhout I; Bhatnagar G; Pelletier M; Voisine P; Demers P; Carrier M; Bouchard D
    Can J Cardiol; 2015 Jan; 31(1):63-8. PubMed ID: 25547552
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Femoral transcatheter valve-in-valve implantation as alternative strategy for failed aortic bioprostheses: A single-centre experience with long-term follow-up.
    Stankowski T; Aboul-Hassan SS; Seifi Zinab F; Herwig V; Stępiński P; Grimmig O; Just S; Harnath A; Muehle A; Fritzsche D; Perek B
    Int J Cardiol; 2020 May; 306():25-34. PubMed ID: 32087937
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transcatheter valve-in-valve implantation using Corevalve Revalving System for failed surgical aortic bioprostheses.
    Bedogni F; Laudisa ML; Pizzocri S; Tamburino C; Ussia GP; Petronio AS; Napodano M; Ramondo A; Presbitero P; Ettori F; Santoro G; Klugman S; De Marco F; Brambilla N; Testa L
    JACC Cardiovasc Interv; 2011 Nov; 4(11):1228-34. PubMed ID: 22115664
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Early experience of implantation of the new CoreValve(®) Evolut(™) in degenerated bioprosthetic aortic valves.
    Fairley SL; Jeganathan R; Manoharan G; Spence MS
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):485-92. PubMed ID: 23857751
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.