These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 25800547)

  • 21. Fast and quiet MRI using a swept radiofrequency.
    Idiyatullin D; Corum C; Park JY; Garwood M
    J Magn Reson; 2006 Aug; 181(2):342-9. PubMed ID: 16782371
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Rapid assessment of longitudinal relaxation time in materials and tissues with extremely fast signal decay using UTE sequences and the variable flip angle method.
    Springer F; Steidle G; Martirosian P; Syha R; Claussen CD; Schick F
    Invest Radiol; 2011 Oct; 46(10):610-7. PubMed ID: 21577126
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Variable-flip-angle single-slab 3D GRASE imaging with phase-independent image reconstruction.
    Kim H; Kim DH; Park J
    Magn Reson Med; 2015 Mar; 73(3):1041-52. PubMed ID: 24639285
    [TBL] [Abstract][Full Text] [Related]  

  • 24. New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.
    Denolin V; Azizieh C; Metens T
    Magn Reson Med; 2005 Oct; 54(4):937-54. PubMed ID: 16155898
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Extending slice coverage for breathhold fat-suppressed T2-weighted fast spin-echo of the liver at 3.0T: application of variable-rate selective-excitation (VERSE) RF pulses.
    van den Bos IC; Hussain SM; Krestin GP; Wielopolski PA
    J Magn Reson Imaging; 2008 Jan; 27(1):110-6. PubMed ID: 18058934
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A comparative numerical study of rotating and stationary RF coils in terms of flip angle and specific absorption rate for 7 T MRI.
    Trakic A; Jin J; Li MY; McClymont D; Weber E; Liu F; Crozier S
    J Magn Reson; 2013 Nov; 236():70-82. PubMed ID: 24076497
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.
    Liu Y; Feng K; McDougall MP; Wright SM; Ji J
    Magn Reson Imaging; 2008 Oct; 26(8):1122-32. PubMed ID: 18440750
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A low power radiofrequency pulse for simultaneous multislice excitation and refocusing.
    Eichner C; Wald LL; Setsompop K
    Magn Reson Med; 2014 Oct; 72(4):949-58. PubMed ID: 25103999
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Correction of excitation profile in Zero Echo Time (ZTE) imaging using quadratic phase-modulated RF pulse excitation and iterative reconstruction.
    Li C; Magland JF; Seifert AC; Wehrli FW
    IEEE Trans Med Imaging; 2014 Apr; 33(4):961-9. PubMed ID: 24710164
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Repetition time and flip angle variation in SPRITE imaging for acquisition time and SAR reduction.
    Shah NJ; Kaffanke JB; Romanzetti S
    J Magn Reson; 2009 Aug; 199(2):136-45. PubMed ID: 19447652
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Imaging of a high concentration of iron labeled cells with positive contrast in a rat knee.
    Magnitsky S; Pickup S; Garwood M; Idiyatullin D
    Magn Reson Med; 2019 Mar; 81(3):1947-1954. PubMed ID: 30242896
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI.
    Drobnitzky M; Klose U
    Med Phys; 2017 Mar; 44(3):873-885. PubMed ID: 28061002
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Role of MRI for detecting micro cracks in teeth.
    Idiyatullin D; Garwood M; Gaalaas L; Nixdorf DR
    Dentomaxillofac Radiol; 2016; 45(7):20160150. PubMed ID: 27402200
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ultrashort echo time and zero echo time MRI at 7T.
    Larson PE; Han M; Krug R; Jakary A; Nelson SJ; Vigneron DB; Henry RG; McKinnon G; Kelley DA
    MAGMA; 2016 Jun; 29(3):359-70. PubMed ID: 26702940
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Gradient-Modulated PETRA MRI.
    Kobayashi N; Goerke U; Wang L; Ellermann J; Metzger GJ; Garwood M
    Tomography; 2015 Dec; 1(2):85-90. PubMed ID: 26771005
    [TBL] [Abstract][Full Text] [Related]  

  • 36. ZTE imaging with enhanced flip angle using modulated excitation.
    Schieban K; Weiger M; Hennel F; Boss A; Pruessmann KP
    Magn Reson Med; 2015 Sep; 74(3):684-93. PubMed ID: 25242318
    [TBL] [Abstract][Full Text] [Related]  

  • 37. MRI of fast-relaxing spins.
    Garwood M
    J Magn Reson; 2013 Apr; 229():49-54. PubMed ID: 23465800
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Root-flipped multiband refocusing pulses.
    Sharma A; Lustig M; Grissom WA
    Magn Reson Med; 2016 Jan; 75(1):227-37. PubMed ID: 25704154
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.
    Wang J; Mao W; Qiu M; Smith MB; Constable RT
    Magn Reson Med; 2006 Aug; 56(2):463-8. PubMed ID: 16773653
    [TBL] [Abstract][Full Text] [Related]  

  • 40. SAR and power implications of different RF shimming strategies in the pelvis for 7T MRI.
    van den Bergen B; van den Berg CA; Klomp DW; Lagendijk JJ
    J Magn Reson Imaging; 2009 Jul; 30(1):194-202. PubMed ID: 19557737
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.