145 related articles for article (PubMed ID: 25802599)
1. Mechanical and biomechanical characterization of a polyurethane nucleus replacement device injected and cured in situ within a balloon.
Tsantrizos A; Ordway NR; Myint K; Martz E; Yuan HA
SAS J; 2008; 2(1):28-39. PubMed ID: 25802599
[TBL] [Abstract][Full Text] [Related]
2. Mechanical testing of a novel hydrogel nucleus replacement implant.
Bertagnoli R; Sabatino CT; Edwards JT; Gontarz GA; Prewett A; Parsons JR
Spine J; 2005; 5(6):672-81. PubMed ID: 16363077
[TBL] [Abstract][Full Text] [Related]
3. Effect of Spiral Nucleus Implant Parameters on the Compressive Biomechanics of Lumbar Intervertebral Disc.
Du CF; Liu CJ; Huang YP; Wang X
World Neurosurg; 2020 Feb; 134():e878-e884. PubMed ID: 31733385
[TBL] [Abstract][Full Text] [Related]
4. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device.
Coogan JS; Francis WL; Eliason TD; Bredbenner TL; Stemper BD; Yoganandan N; Pintar FA; Nicolella DP
Front Bioeng Biotechnol; 2016; 4():93. PubMed ID: 27990418
[TBL] [Abstract][Full Text] [Related]
5. Bionate
Vanaclocha A; Vanaclocha V; Atienza CM; Clavel P; Jordá-Gómez P; Barrios C; Vanaclocha L
J Orthop Traumatol; 2023 Apr; 24(1):13. PubMed ID: 37041425
[TBL] [Abstract][Full Text] [Related]
6. Restoration of compressive loading properties of lumbar discs with a nucleus implant-a finite element analysis study.
Strange DG; Fisher ST; Boughton PC; Kishen TJ; Diwan AD
Spine J; 2010 Jul; 10(7):602-9. PubMed ID: 20547110
[TBL] [Abstract][Full Text] [Related]
7. Effect of nucleus replacement device properties on lumbar spine mechanics.
Rundell SA; Guerin HL; Auerbach JD; Kurtz SM
Spine (Phila Pa 1976); 2009 Sep; 34(19):2022-32. PubMed ID: 19730210
[TBL] [Abstract][Full Text] [Related]
8. Nubac disc arthroplasty: preclinical studies and preliminary safety and efficacy evaluations.
Bao QB; Songer M; Pimenta L; Werner D; Reyes-Sanchez A; Balsano M; Agrillo U; Coric D; Davenport K; Yuan H
SAS J; 2007; 1(1):36-45. PubMed ID: 25802577
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical function of a balloon nucleus pulposus replacement system: A human cadaveric spine study.
Lee T; Lim TH; Lee SH; Kim JH; Hong J
J Orthop Res; 2018 Jan; 36(1):167-173. PubMed ID: 28513885
[TBL] [Abstract][Full Text] [Related]
10. Fill of the nucleus cavity affects mechanical stability in compression, bending, and torsion of a spine segment, which has undergone nucleus replacement.
Arthur A; Cannella M; Keane M; Singhatat W; Vresilovic E; Marcolongo M
Spine (Phila Pa 1976); 2010 May; 35(11):1128-35. PubMed ID: 20473120
[TBL] [Abstract][Full Text] [Related]
11. Translational challenges for the development of a novel nucleus pulposus substitute: Experimental results from biomechanical and in vivo studies.
Detiger SE; de Bakker JY; Emanuel KS; Schmitz M; Vergroesen PP; van der Veen AJ; Mazel C; Smit TH
J Biomater Appl; 2016 Feb; 30(7):983-94. PubMed ID: 26494611
[TBL] [Abstract][Full Text] [Related]
12. Phase 1 evaluation of an elastomeric nucleus pulposus device as an option to augment disc at microdiscectomy: Experimental results from biomechanical and biocompatibility testing and first in human.
Chen X; Kohan S; Bhargav D; Choi J; Perera S; Dean C; Chopra N; Sial A; Sandhu HS; Apos E; Appleyard R; Diwan AD
JOR Spine; 2023 Jun; 6(2):e1250. PubMed ID: 37361335
[TBL] [Abstract][Full Text] [Related]
13. The restoration of lumbar intervertebral disc load distribution: a comparison of three nucleus replacement technologies.
Dahl MC; Ahrens M; Sherman JE; Martz EO
Spine (Phila Pa 1976); 2010 Jul; 35(15):1445-53. PubMed ID: 20216342
[TBL] [Abstract][Full Text] [Related]
14. Porous coated motion cervical disc replacement: a biomechanical, histomorphometric, and biologic wear analysis in a caprine model.
Hu N; Cunningham BW; McAfee PC; Kim SW; Sefter JC; Cappuccino A; Pimenta L
Spine (Phila Pa 1976); 2006 Jul; 31(15):1666-73. PubMed ID: 16816760
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical analysis of rotational motions after disc arthroplasty: implications for patients with adult deformities.
McAfee PC; Cunningham BW; Hayes V; Sidiqi F; Dabbah M; Sefter JC; Hu N; Beatson H
Spine (Phila Pa 1976); 2006 Sep; 31(19 Suppl):S152-60. PubMed ID: 16946633
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model.
Cunningham BW; Gordon JD; Dmitriev AE; Hu N; McAfee PC
Spine (Phila Pa 1976); 2003 Oct; 28(20):S110-7. PubMed ID: 14560182
[TBL] [Abstract][Full Text] [Related]
17. [An improved vertebral body replacement for the thoracolumbar spine. A biomechanical in vitro test on human lumbar vertebral bodies].
Reinhold M; Schmölz W; Canto F; Krappinger D; Blauth M; Knop C
Unfallchirurg; 2007 Apr; 110(4):327-33. PubMed ID: 17211598
[TBL] [Abstract][Full Text] [Related]
18. Cervical disc replacement-porous coated motion prosthesis: a comparative biomechanical analysis showing the key role of the posterior longitudinal ligament.
McAfee PC; Cunningham B; Dmitriev A; Hu N; Woo Kim S; Cappuccino A; Pimenta L
Spine (Phila Pa 1976); 2003 Oct; 28(20):S176-85. PubMed ID: 14560189
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical assessment and fatigue characteristics of an articulating nucleus implant.
Ordway NR; Lavelle WF; Brown T; Bao QB
Int J Spine Surg; 2013; 7():e109-17. PubMed ID: 25694897
[TBL] [Abstract][Full Text] [Related]
20. Effect of a prosthetic disc nucleus on the mobility and disc height of the L4-5 intervertebral disc postnucleotomy.
Wilke HJ; Kavanagh S; Neller S; Haid C; Claes LE
J Neurosurg; 2001 Oct; 95(2 Suppl):208-14. PubMed ID: 11599838
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]