These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 25808762)

  • 1. Ultra-sensitive nanofiber fluorescence detection in a microfluidic chip.
    Li Z; Xu Y; Fang W; Tong L; Zhang L
    Sensors (Basel); 2015 Feb; 15(3):4890-8. PubMed ID: 25808762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultra-sensitive microfibre absorption detection in a microfluidic chip.
    Zhang L; Wang P; Xiao Y; Yu H; Tong L
    Lab Chip; 2011 Nov; 11(21):3720-4. PubMed ID: 21947202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Colorimetric detection of urine glucose using a C/CdTe QDs-GOx aerogel based on a microfluidic assay sensor.
    Hu T; Xu K; Qiu S; Han Y; Chen J; Xu J; Chen K; Sun Z; Yi H; Ni Z
    J Mater Chem B; 2020 Aug; 8(32):7160-7165. PubMed ID: 32567624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rhodamine 6G conjugated-quantum dots used for highly sensitive and selective ratiometric fluorescence sensor of glutathione.
    Gui R; An X; Su H; Shen W; Zhu L; Ma X; Chen Z; Wang X
    Talanta; 2012 May; 94():295-300. PubMed ID: 22608451
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coiled Optical Nanofiber for Optofluidic Absorbance Detection.
    Mei H; Pan J; Zhang Z; Zhang L; Tong L
    ACS Sens; 2019 Sep; 4(9):2267-2271. PubMed ID: 31385506
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Femtoliter-scale optical nanofiber sensors.
    Zhang L; Li Z; Mu J; Fang W; Tong L
    Opt Express; 2015 Nov; 23(22):28408-15. PubMed ID: 26561111
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The detection of p53 gene via fluorescence quenching of quantum dot in microfluidic chip.
    Yoo JH; Yoo IS; Yoon WJ; Kim JS
    J Nanosci Nanotechnol; 2012 May; 12(5):4109-14. PubMed ID: 22852354
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Application of novel quantum dot-based molecularly imprinted fluorescence sensor in rapid detection].
    Ma J; Lian Z; He C; Wang J; Yu R
    Se Pu; 2021 Aug; 39(8):775-780. PubMed ID: 34212579
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Selectable Ultrasensitive Detection of Hg(2+) with Rhodamine 6G-Modified Nanoporous Gold Optical Sensor.
    Wang Z; Yang M; Chen C; Zhang L; Zeng H
    Sci Rep; 2016 Jul; 6():29611. PubMed ID: 27403721
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantum dot/carrier-protein/haptens conjugate as a detection nanobioprobe for FRET-based immunoassay of small analytes with all-fiber microfluidic biosensing platform.
    Long F; Gu C; Gu AZ; Shi H
    Anal Chem; 2012 Apr; 84(8):3646-53. PubMed ID: 22455400
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitive detection of polycyclic aromatic hydrocarbons using CdTe quantum dot-modified TiO₂ nanotube array through fluorescence resonance energy transfer.
    Yang L; Chen B; Luo S; Li J; Liu R; Cai Q
    Environ Sci Technol; 2010 Oct; 44(20):7884-9. PubMed ID: 20849105
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metal-organic frame material encapsulated Rhodamine 6G: A highly sensitive fluorescence sensing platform for the detection of picric acid contaminants in water.
    Lv W; Song Y; Guo R; Liu N; Mo Z
    Spectrochim Acta A Mol Biomol Spectrosc; 2024 Aug; 316():124355. PubMed ID: 38701575
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Visual detection of mixed organophosphorous pesticide using QD-AChE aerogel based microfluidic arrays sensor.
    Hu T; Xu J; Ye Y; Han Y; Li X; Wang Z; Sun D; Zhou Y; Ni Z
    Biosens Bioelectron; 2019 Jul; 136():112-117. PubMed ID: 31054518
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Establishment of a Ca(II) ion-quantum dots fluorescence signal amplification sensor for high-sensitivity biomarker detection.
    Lv Y; Wang P; Li J; Li N; Xu D; Wu R; Shen H; Li LS
    Anal Chim Acta; 2023 Jan; 1237():340534. PubMed ID: 36442931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a quantum dot molecularly imprinted polymer sensor for fluorescence detection of atrazine.
    Nsibande SA; Forbes PBC
    Luminescence; 2019 Aug; 34(5):480-488. PubMed ID: 30834666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Homogeneous immunoassays based on fluorescence emission intensity variations of zinc selenide quantum dot sensors.
    Wang J; Mountziaris TJ
    Biosens Bioelectron; 2013 Mar; 41():143-9. PubMed ID: 22960008
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface plasmon coupling effects on the förster resonance energy transfer from quantum dot into rhodamine 6G.
    Chen CY; Ni CC; Wu RN; Kuo SY; Li CH; Kiang YW; Yang CC
    Nanotechnology; 2021 Apr; 32(29):. PubMed ID: 33848997
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microfluidic biosensor for the detection of DNA by fluorescence enhancement and the following streptavidin detection by fluorescence quenching.
    Wang J; Aki M; Onoshima D; Arinaga K; Kaji N; Tokeshi M; Fujita S; Yokoyama N; Baba Y
    Biosens Bioelectron; 2014 Jan; 51():280-5. PubMed ID: 23974159
    [TBL] [Abstract][Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.