These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
177 related articles for article (PubMed ID: 25809547)
1. Evaluation of Ignition and Burn Risk Associated with Contemporary Fiberoptic and Distal Sensor Endoscopic Technology. Spradling K; Uribe B; Okhunov Z; Hofmann M; Del Junco M; Hwang C; Gruber C; Youssef RF; Landman J J Endourol; 2015 Sep; 29(9):1076-82. PubMed ID: 25809547 [TBL] [Abstract][Full Text] [Related]
2. Comparison of optical resolution with digital and standard fiberoptic cystoscopes in an in vitro model. Quayle SS; Ames CD; Lieber D; Yan Y; Landman J Urology; 2005 Sep; 66(3):489-93. PubMed ID: 16140063 [TBL] [Abstract][Full Text] [Related]
4. In vitro and in vivo comparison of optics and performance of a distal sensor ureteroscope versus a standard fiberoptic ureteroscope. Lusch A; Abdelshehid C; Hidas G; Osann KE; Okhunov Z; McDougall E; Landman J J Endourol; 2013 Jul; 27(7):896-902. PubMed ID: 23402369 [TBL] [Abstract][Full Text] [Related]
5. Comparison of resolution, contrast, and color differentiation among fiberoptic and digital flexible cystoscopes. Borin JF; Abdelshehid CS; Clayman RV J Endourol; 2006 Jan; 20(1):54-8. PubMed ID: 16426134 [TBL] [Abstract][Full Text] [Related]
6. Fire/burn risk with electrosurgical devices and endoscopy fiberoptic cables. Smith LP; Roy S Am J Otolaryngol; 2008; 29(3):171-6. PubMed ID: 18439950 [TBL] [Abstract][Full Text] [Related]
7. Thermal injury to common operating room materials by fiber optic light sources and endoscopes. Prasad N; Tavaluc R; Harley E Am J Otolaryngol; 2019; 40(5):631-635. PubMed ID: 31178283 [TBL] [Abstract][Full Text] [Related]
8. Reducing fire and burn risk in the operating room-testing of a novel device. Roy S; Yu KM; Knackstedt MI; Webb NH; Smith LP Surg Endosc; 2021 Dec; 35(12):6969-6976. PubMed ID: 33398551 [TBL] [Abstract][Full Text] [Related]
9. Flexible endoscope deflectability: changes using a variety of working instruments and laser fibers. Poon M; Beaghler M; Baldwin D J Endourol; 1997 Aug; 11(4):247-9. PubMed ID: 9376842 [TBL] [Abstract][Full Text] [Related]
10. Comparison of optics and performance of a distal sensor high definition cystoscope, a distal sensor standard definition cystoscope, and a fiberoptic cystoscope. Lusch A; Liss MA; Greene P; Abdelshehid C; Menhadji A; Bucur P; Alipanah R; McDougall E; Landman J Urology; 2013 Dec; 82(6):1226-30. PubMed ID: 24094651 [TBL] [Abstract][Full Text] [Related]
13. The digital flexible ureteroscope: in vitro assessment of optical characteristics. Zilberman DE; Lipkin ME; Ferrandino MN; Simmons WN; Mancini JG; Raymundo ME; Zhong P; Preminger GM J Endourol; 2011 Mar; 25(3):519-22. PubMed ID: 21361823 [TBL] [Abstract][Full Text] [Related]
14. Total radiated power, infrared output, and heat generation by cold light sources at the distal end of endoscopes and fiber optic bundle of light cables. Hensman C; Hanna GB; Drew T; Moseley H; Cuschieri A Surg Endosc; 1998 Apr; 12(4):335-7. PubMed ID: 9543524 [TBL] [Abstract][Full Text] [Related]