These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 25809547)

  • 41. Office flexible cystoscopy.
    Kavoussi LR; Clayman RV
    Urol Clin North Am; 1988 Nov; 15(4):601-8. PubMed ID: 3055614
    [TBL] [Abstract][Full Text] [Related]  

  • 42. In vitro comparison of a disposable flexible ureteroscope and conventional flexible ureteroscopes.
    Boylu U; Oommen M; Thomas R; Lee BR
    J Urol; 2009 Nov; 182(5):2347-51. PubMed ID: 19758626
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Ureteroscopes: flexible, rigid, and semirigid.
    Basillote JB; Lee DI; Eichel L; Clayman RV
    Urol Clin North Am; 2004 Feb; 31(1):21-32. PubMed ID: 15040398
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The Use of Flexible Fiberoptic Cystoscope for Difficult Endotracheal Intubation in TMJ Ankylosis Patients: A Case Series.
    Al-Khateeb TH; Rabad DK
    Middle East J Anaesthesiol; 2016 Oct; 23(6):679-83. PubMed ID: 29939707
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Comparison of hexaminolevulinate based flexible and rigid fluorescence cystoscopy with rigid white light cystoscopy in bladder cancer: results of a prospective Phase II study.
    Witjes JA; Moonen PM; van der Heijden AG
    Eur Urol; 2005 Mar; 47(3):319-22. PubMed ID: 15716194
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Transurethral Pneumatic Cystolithotripsy: A Novel Approach.
    Ali AI; Fathelbab TK; Abdelhamid AM; Elbadry M; Alshara L; Anwar AZ; Galal EM; Tawfiek ER
    J Endourol; 2016 Jun; 30(6):671-3. PubMed ID: 26979575
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Bedside flexible cystoscopy: an approach to the critically ill patient.
    Clayman RV; Kramolowsky EV
    J Urol; 1986 Jun; 135(6):1179-80. PubMed ID: 3712564
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Comparison of flexible ureteroscopes: deflection, irrigant flow and optical characteristics.
    Abdelshehid C; Ahlering MT; Chou D; Park HK; Basillote J; Lee D; Kim I; Eichel L; Protsenko D; Wong B; McDougall E; Clayman RV
    J Urol; 2005 Jun; 173(6):2017-21. PubMed ID: 15879808
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Silent burn: the hidden danger and effects of bright light from fibre-optic cables in arthroscopic knee surgery.
    Chitnavis J
    J Surg Case Rep; 2020 Apr; 2020(4):rjaa068. PubMed ID: 32280444
    [TBL] [Abstract][Full Text] [Related]  

  • 50. No smoke without fire--simple recommendations to avoid arthroscopic burns.
    Sandhu H; Turner R; Pozo JL
    Knee; 2002 Dec; 9(4):341-6. PubMed ID: 12424045
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Endoscopic transaxillary thyroid lobectomy: flexible vs rigid laparoscope.
    Udomsawaengsup S; Navicharern P; Tharavej C; Pungpapong SU
    J Med Assoc Thai; 2004 Sep; 87 Suppl 2():S10-4. PubMed ID: 16083153
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Durability of working channel in flexible ureteroscopes when inserting ureteroscopic devices.
    Seto C; Ishiura Y; Egawa M; Komatsu K; Namiki M
    J Endourol; 2006 Mar; 20(3):223-6. PubMed ID: 16548735
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Interference in a pulse oximeter from a fiberoptic light source.
    Block FE
    J Clin Monit; 1987 Jul; 3(3):210-1. PubMed ID: 3612219
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Frequency of ureteroscope damage seen at a tertiary care center.
    Carey RI; Gomez CS; Maurici G; Lynne CM; Leveillee RJ; Bird VG
    J Urol; 2006 Aug; 176(2):607-10; discussion 610. PubMed ID: 16813899
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Thermal Variations of Operative Microscopes in Otology.
    Imbery TE; Tampio AJ; Nicholas BD
    Otolaryngol Head Neck Surg; 2017 Jul; 157(1):113-116. PubMed ID: 28195746
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Surgical video systems.
    Health Devices; 1995 Nov; 24(11):428-74. PubMed ID: 8750067
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The Endockscope Using Next Generation Smartphones: "A Global Opportunity".
    Tse C; Patel RM; Yoon R; Okhunov Z; Landman J; Clayman RV
    J Endourol; 2018 Aug; 32(8):765-770. PubMed ID: 29860870
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Using a Video-Laparoscope for Intraoperative Colonoscopy: An Experimental Study on Intraluminal Temperature Values and Tissue Damage.
    Şimşek T; Büyükgebiz O; Şahin D; Güneş A; Gürbüz Y
    Surg Laparosc Endosc Percutan Tech; 2018 Aug; 28(4):e78-e82. PubMed ID: 29746424
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Post-cystoscopy infections and device malfunctions in reprocessed flexible cystoscopes in a national database.
    Lee J; Kaplan-Marans E; Jivanji D; Tennenbaum D; Schulman A
    Can J Urol; 2022 Dec; 29(6):11361-11365. PubMed ID: 36495577
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Evaluation of a protective laser sheath for application in flexible ureteroscopy.
    Durak E; Hruby G; Mitchell R; Marruffo F; Abundez JO; Landman J
    J Endourol; 2008 Jan; 22(1):57-60. PubMed ID: 18315475
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.