These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 25813957)
1. Effects of plaque lengths on stent surface roughness. Syaifudin A; Takeda R; Sasaki K Biomed Mater Eng; 2015; 25(2):189-202. PubMed ID: 25813957 [TBL] [Abstract][Full Text] [Related]
2. Development of asymmetric stent for treatment of eccentric plaque. Syaifudin A; Takeda R; Sasaki K Biomed Mater Eng; 2018; 29(3):299-317. PubMed ID: 29578470 [TBL] [Abstract][Full Text] [Related]
3. Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery--finite element simulation. Schiavone A; Zhao LG; Abdel-Wahab AA Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():479-88. PubMed ID: 25063145 [TBL] [Abstract][Full Text] [Related]
4. Finite element evaluation of artery damage in deployment of polymeric stent with pre- and post-dilation. He R; Zhao LG; Silberschmidt VV; Liu Y; Vogt F Biomech Model Mechanobiol; 2020 Feb; 19(1):47-60. PubMed ID: 31317295 [TBL] [Abstract][Full Text] [Related]
5. Tissue prolapse and stresses in stented coronary arteries: A computer model for multi-layer atherosclerotic plaque. Hajiali Z; Dabagh M; Debusschere N; De Beule M; Jalali P Comput Biol Med; 2015 Nov; 66():39-46. PubMed ID: 26378501 [TBL] [Abstract][Full Text] [Related]
6. Mechanical Interaction of an Expanding Coiled Stent with a Plaque-Containing Arterial Wall: A Finite Element Analysis. Welch TR; Eberhart RC; Banerjee S; Chuong CJ Cardiovasc Eng Technol; 2016 Mar; 7(1):58-68. PubMed ID: 26621671 [TBL] [Abstract][Full Text] [Related]
7. Vulnerability analysis on the interaction between Asymmetric stent and arterial layer. Syaifudin A; Ariatedja JB; Kaelani Y; Takeda R; Sasaki K Biomed Mater Eng; 2019; 30(3):309-322. PubMed ID: 31127751 [TBL] [Abstract][Full Text] [Related]
8. An experimental-nonlinear finite element study of a balloon expandable stent inside a realistic stenotic human coronary artery to investigate plaque and arterial wall injury. Karimi A; Razaghi R; Shojaei A; Navidbakhsh M Biomed Tech (Berl); 2015 Dec; 60(6):593-602. PubMed ID: 25870956 [TBL] [Abstract][Full Text] [Related]
9. Influences of plaque eccentricity and composition on the stent-plaque-artery interaction during stent implantation. Wei L; Chen Q; Li Z Biomech Model Mechanobiol; 2019 Feb; 18(1):45-56. PubMed ID: 30097815 [TBL] [Abstract][Full Text] [Related]
10. Analysis of the stent expansion in a stenosed artery using finite element method: application to stent versus stent study. Imani SM; Goudarzi AM; Ghasemi SE; Kalani A; Mahdinejad J Proc Inst Mech Eng H; 2014 Oct; 228(10):996-1004. PubMed ID: 25406228 [TBL] [Abstract][Full Text] [Related]
11. The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents. Pericevic I; Lally C; Toner D; Kelly DJ Med Eng Phys; 2009 May; 31(4):428-33. PubMed ID: 19129001 [TBL] [Abstract][Full Text] [Related]
12. Characterizing the expansive deformation of a bioresorbable polymer fiber stent. Welch T; Eberhart RC; Chuong CJ Ann Biomed Eng; 2008 May; 36(5):742-51. PubMed ID: 18264765 [TBL] [Abstract][Full Text] [Related]
13. Finite element analysis and stent design: Reduction of dogboning. De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746 [TBL] [Abstract][Full Text] [Related]
14. Modelling of atherosclerotic plaque for use in a computational test-bed for stent angioplasty. Conway C; McGarry JP; McHugh PE Ann Biomed Eng; 2014 Dec; 42(12):2425-39. PubMed ID: 25209735 [TBL] [Abstract][Full Text] [Related]
15. An analysis of the contact between the stent and the artery using tube hydroforming simulation. Araújo R; Guimarães TA; Oliveira SA Int J Numer Method Biomed Eng; 2013 Nov; 29(11):1214-22. PubMed ID: 23813983 [TBL] [Abstract][Full Text] [Related]
16. A numerical study on the application of the functionally graded materials in the stent design. Khosravi A; Bahreinizad H; Bani MS; Karimi A Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():182-188. PubMed ID: 28183596 [TBL] [Abstract][Full Text] [Related]
17. A nonlinear finite element simulation of balloon expandable stent for assessment of plaque vulnerability inside a stenotic artery. Karimi A; Navidbakhsh M; Yamada H; Razaghi R Med Biol Eng Comput; 2014 Jul; 52(7):589-99. PubMed ID: 24888756 [TBL] [Abstract][Full Text] [Related]
18. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques. Fan Z; Liu X; Sun A; Zhang N; Fan Z; Fan Y; Deng X Med Eng Phys; 2017 Oct; 48():114-119. PubMed ID: 28826570 [TBL] [Abstract][Full Text] [Related]
19. Structural analysis of two different stent configurations. Simão M; Ferreira JM; Mora-Rodriguez J; Ramos HM Comput Methods Biomech Biomed Engin; 2017 Jun; 20(8):869-883. PubMed ID: 28317393 [TBL] [Abstract][Full Text] [Related]