BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

318 related articles for article (PubMed ID: 25816961)

  • 1. Early stenosis of an aortic porcine bioprosthesis due to thrombosis: Case report and literature review.
    Dohi M; Doi K; Yaku H
    J Thorac Cardiovasc Surg; 2015 Jun; 149(6):e83-6. PubMed ID: 25816961
    [No Abstract]   [Full Text] [Related]  

  • 2. Early failures of Trifecta aortic bioprosthesis.
    Campisi S; Camilleri L; Innorta A; Azarnoush K
    J Thorac Cardiovasc Surg; 2014 Jul; 148(1):e133-4. PubMed ID: 24755333
    [No Abstract]   [Full Text] [Related]  

  • 3. Early structural valve deterioration of the Trifecta aortic valve biological prosthesis: a word of caution.
    Saxena P; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):e10-1. PubMed ID: 24041765
    [No Abstract]   [Full Text] [Related]  

  • 4. The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study.
    Bavaria JE; Desai ND; Cheung A; Petracek MR; Groh MA; Borger MA; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Feb; 147(2):590-7. PubMed ID: 23477687
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioprosthetic aortic valve replacement on a mechanical valve ring.
    Ashraf O; Yadav S
    Asian Cardiovasc Thorac Ann; 2015 Nov; 23(9):1060-1. PubMed ID: 24732085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Early stenotic prosthesis failure after implantation of a stentless porcine aortic valve prosthesis.
    Donndorf P; Westphal B; Steinhoff G
    Interact Cardiovasc Thorac Surg; 2011 Sep; 13(3):348-9. PubMed ID: 21712349
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Subacute transcatheter CoreValve thrombotic obstruction.
    Lancellotti P; Radermecker MA; Weisz SH; Legrand V
    Circ Cardiovasc Interv; 2013 Jun; 6(3):e32-3. PubMed ID: 23780297
    [No Abstract]   [Full Text] [Related]  

  • 8. The Mosaic porcine bioprosthesis: role of age on clinical performance in aortic position.
    Riess FC; Bader R; Cramer E; Hansen L; Schiffelers S; Wallrath J; Wahl G
    J Thorac Cardiovasc Surg; 2011 Jun; 141(6):1440-8.e1. PubMed ID: 20850804
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aortic bioprosthesis--avoid obstructive properties due to thrombosis as altered durability due to structural valve deterioration.
    Jamieson WR; Fradet GJ
    J Thorac Cardiovasc Surg; 2010 May; 139(5):1354. PubMed ID: 20412968
    [No Abstract]   [Full Text] [Related]  

  • 10. Bailout surgical explantation of a transcatheter valve-in-valve for subacute thrombosis: When there is no time for anticoagulation: Case report and literature review.
    Notaristefano F; Reccia MR; Notaristefano S; Annunziata R; Sclafani R; Ambrosio G; Cavallini C
    Cardiovasc Revasc Med; 2018 Jul; 19(5 Pt A):536-539. PubMed ID: 29352701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic valve in valve insertion: a note of caution and a case for possible optimism.
    Dean LS
    Catheter Cardiovasc Interv; 2010 Dec; 76(7):1007-8. PubMed ID: 21108376
    [No Abstract]   [Full Text] [Related]  

  • 12. Early stenosis of Medtronic Mosaic bioprosthesis in the aortic position.
    Peeceeyen S; Cao C; Fermanis G; Manganas C
    J Thorac Cardiovasc Surg; 2012 Feb; 143(2):e13-4. PubMed ID: 22104666
    [No Abstract]   [Full Text] [Related]  

  • 13. Achilles' heel of stentless porcine valves.
    Thiene G; Valente M
    Cardiovasc Pathol; 2007; 16(5):257. PubMed ID: 17868875
    [No Abstract]   [Full Text] [Related]  

  • 14. Acute bioprosthetic thrombosis immediately after aortic valve replacement.
    Patanè F; Sansone F; Campanella A; Asteggiano F; Rinaldi M
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):167-9. PubMed ID: 19194176
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relation between hemodynamic behavior and occurrence of early stenotic failure of bioprostheses.
    Meuris B; Flameng W
    J Thorac Cardiovasc Surg; 2010 Nov; 140(5):1200; author reply 1200-1. PubMed ID: 20951264
    [No Abstract]   [Full Text] [Related]  

  • 16. Stentless aortic reoperation: New surgical strategy with rapid deployment valves.
    Martinelli GL; Cotroneo A; Greco P; Cassese M
    J Thorac Cardiovasc Surg; 2015 Jun; 149(6):e88-9. PubMed ID: 25873291
    [No Abstract]   [Full Text] [Related]  

  • 17. Early and intermediate outcome after aortic valve replacement with a sutureless bioprosthesis: Results of a multicenter study.
    Rubino AS; Santarpino G; De Praetere H; Kasama K; Dalén M; Sartipy U; Lahtinen J; Heikkinen J; Deste W; Pollari F; Svenarud P; Meuris B; Fischlein T; Mignosa C; Biancari F
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):865-71; discussion 871. PubMed ID: 24954175
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sutureless Perceval aortic valve in comparison with the stented Carpentier-Edwards Perimount aortic valve.
    König KC; Wahlers T; Scherner M; Wippermann J
    J Heart Valve Dis; 2014 Mar; 23(2):253-8. PubMed ID: 25076560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation.
    Piñón M; Durán D; Pazos P; Pradas G
    Interact Cardiovasc Thorac Surg; 2015 Feb; 20(2):281-2. PubMed ID: 25404230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Re: mid-term evaluation of Sorin Soprano bioprostheses in patients with a small aortic annulus Bockeria LA; Scopin II; Makushin AA
    Interact Cardiovasc Thorac Surg; 2010 Mar; 10(3):402. PubMed ID: 20185844
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 16.