BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 2582662)

  • 1. Cementless press-fit cup. Principles, experimental data, and three-year follow-up study.
    Morscher E; Bereiter H; Lampert C
    Clin Orthop Relat Res; 1989 Dec; (249):12-20. PubMed ID: 2582662
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Principles of acetabular fixation in THR with special reference to the "press-fit cup".
    Morscher E
    Acta Orthop Belg; 1993; 59 Suppl 1():260-6. PubMed ID: 8116408
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and first experience with an uncemented press-fit cup.
    Morscher E; Masar Z
    Clin Orthop Relat Res; 1988 Jul; (232):96-103. PubMed ID: 3383507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
    Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
    Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years.
    Schmalzried TP; Harris WH
    J Bone Joint Surg Am; 1992 Sep; 74(8):1130-9. PubMed ID: 1400541
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Allofit cementless acetabular component: five-year experience].
    Hoza P; Pilný J; Kubeš J
    Acta Chir Orthop Traumatol Cech; 2013; 80(2):148-54. PubMed ID: 23562260
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The temporal behavior of the anchorage of a cement-free implanted acetabular cup in animal experiments].
    Bereiter H; Bürgi M; Rahn BA
    Orthopade; 1992 Feb; 21(1):63-70. PubMed ID: 1549340
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Roentgen criteria and radiologic results of the Hofer-Imhof (H-I) threaded acetabulum cup in first time implantation].
    Effenberger H; Weber M; Dorn U; Hofer H
    Z Orthop Ihre Grenzgeb; 1997; 135(5):434-43. PubMed ID: 9446437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Contact surface and pressure load at implant-bone interface in press-fit cups compared to natural hip joints].
    Widmer KH; Zurfluh B; Morscher EW
    Orthopade; 1997 Feb; 26(2):181-9. PubMed ID: 9157358
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures.
    Morscher E; Berli B; Jockers W; Schenk R
    Clin Orthop Relat Res; 1997 Aug; (341):42-50. PubMed ID: 9269153
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The acetabular component in total hip arthroplasty. Evaluation of different fixation principles.
    Thanner J
    Acta Orthop Scand Suppl; 1999 Aug; 286():1-41. PubMed ID: 10572504
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up.
    Cheung KW; Yung SH; Wong KC; Chiu KH
    J Arthroplasty; 2005 Aug; 20(5):627-31. PubMed ID: 16309999
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Revision total hip arthroplasty using a cementless acetabular component: technique and results.
    Silverton CD; Rosenberg AG; Sheinkop MB; Kull LR; Galante JO
    Semin Arthroplasty; 1995 Apr; 6(2):109-17. PubMed ID: 10155687
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The dual radius hemispherical 'Trident" cup: results based on 150 consecutive cases.
    Bonicoli E; Baluganti A; Andreani L; Piolanti N; Lisanti M
    Surg Technol Int; 2012 Dec; 22():229-35. PubMed ID: 23109072
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 20-year Results of a 3D Titanium Mesh Coating Stability of 31 Artificial Cups.
    Koch K; Nolte I; Hahn M; Becker A
    Z Orthop Unfall; 2024 Jun; 162(3):263-271. PubMed ID: 37044122
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Results of the Evora dual-mobility socket after a minimum follow-up of five years.
    Leclercq S; Benoit JY; de Rosa JP; Euvrard P; Leteurtre C; Girardin P
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Dec; 94(8):e17-22. PubMed ID: 19070709
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Survival of cementless dual mobility socket with a mean 17 years follow-up.
    Philippot R; Farizon F; Camilleri JP; Boyer B; Derhi G; Bonnan J; Fessy MH; Lecuire F
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Dec; 94(8):e23-7. PubMed ID: 19070710
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A titanium plasma-sprayed cup with and without hydroxyapatite-coating: a randomised radiostereometric study of stability and osseointegration.
    Munzinger U; Guggi T; Kaptein B; Persoon M; Valstar E; Doets HC
    Hip Int; 2013; 23(1):33-9. PubMed ID: 23329538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
    Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
    Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.
    Reikerås O; Gunderson RB
    Arch Orthop Trauma Surg; 2006 Oct; 126(8):503-8. PubMed ID: 16799792
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.