These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 25828843)

  • 1. Do fluoroscopy systems influence the level of scatter radiation exposure during endoscopic procedures?
    Bang JY; Hawes RH; Varadarajulu S
    Dig Endosc; 2015 Jul; 27(5):629. PubMed ID: 25828843
    [No Abstract]   [Full Text] [Related]  

  • 2. Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy.
    Lee SY; Min E; Bae J; Chung CY; Lee KM; Kwon SS; Park MS; Lee K
    Spine (Phila Pa 1976); 2013 Nov; 38(24):2108-12. PubMed ID: 23963017
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dangers of high-dose fluoroscopy.
    Parks PM
    Radiol Technol; 2003; 74(5):427-30. PubMed ID: 12800570
    [No Abstract]   [Full Text] [Related]  

  • 4. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.
    Lee K; Lee KM; Park MS; Lee B; Kwon DG; Chung CY
    Spine (Phila Pa 1976); 2012 Jun; 37(14):1240-4. PubMed ID: 22198350
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Procedures, spectrum and radiation exposure in CT-fluoroscopy].
    Stoeckelhuber BM; Schulz E; Melchert UH; Blobel J; Gellissen J; Gehl H; Weiss HD; Leibecke T
    Rontgenpraxis; 2003; 55(2):51-7. PubMed ID: 14618963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A simple technique to reduce surgeon radiation exposure during the use of the mini C-arm fluoroscope.
    Smith J; Frood R; Southern S
    Ann R Coll Surg Engl; 2015 Mar; 97(2):160. PubMed ID: 25723701
    [No Abstract]   [Full Text] [Related]  

  • 7. Cervical spine imaging using mini--C-arm fluoroscopy: patient and surgeon exposure to direct and scatter radiation.
    Giordano BD; Baumhauer JF; Morgan TL; Rechtine GR
    J Spinal Disord Tech; 2009 Aug; 22(6):399-403. PubMed ID: 19652564
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparing strategies for operator eye protection in the interventional radiology suite.
    Thornton RH; Dauer LT; Altamirano JP; Alvarado KJ; St Germain J; Solomon SB
    J Vasc Interv Radiol; 2010 Nov; 21(11):1703-7. PubMed ID: 20920841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reducing occupational exposure from fluoroscopy.
    Detorie N; Mahesh M; Schueler BA
    J Am Coll Radiol; 2007 May; 4(5):335-7. PubMed ID: 17467618
    [No Abstract]   [Full Text] [Related]  

  • 10. [Radiation dosage of the surgery from intraoperative roentgen procedures: risks and dose management in the operating room].
    Fuchs M; Schmid A; Eiteljörge T; Modler H; Stürmer KM
    Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1111-3. PubMed ID: 9931807
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation exposure to the hands from mini C-arm fluoroscopy.
    Singer G
    J Hand Surg Am; 2005 Jul; 30(4):795-7. PubMed ID: 16039374
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiation protection education in fluoroscopy.
    Johnson MM
    Radiol Technol; 2015; 86(5):511-28; quiz 528-32. PubMed ID: 25995403
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The ABC guide for the safe use of mini C-arms.
    Jing SS; Iyer S
    Ann R Coll Surg Engl; 2015 Mar; 97(2):162. PubMed ID: 25723703
    [No Abstract]   [Full Text] [Related]  

  • 14. Risks of radiation exposure to orthopaedic surgeons.
    O'Rourke PJ; Crerand S; Harrington P; Casey M; Quinlan W
    J R Coll Surg Edinb; 1996 Feb; 41(1):40-3. PubMed ID: 8930041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hand and body radiation exposure with the use of mini C-arm fluoroscopy.
    Tuohy CJ; Weikert DR; Watson JT; Lee DH
    J Hand Surg Am; 2011 Apr; 36(4):632-8. PubMed ID: 21349658
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Exposure from the large C-arm versus the mini C-arm using hand/wrist and elbow phantoms.
    Singer G; Herron B; Herron D
    J Hand Surg Am; 2011 Apr; 36(4):628-31. PubMed ID: 21414730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of a sterile, disposable, radiation-absorbing shield reduces occupational exposure to scatter radiation during pectoral device implantation.
    Simons GR; Orrison WW
    Pacing Clin Electrophysiol; 2004 Jun; 27(6 Pt 1):726-9. PubMed ID: 15189526
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radiation protection during percutaneous nephrolithotomy: a new urologic surgery radiation shield.
    Yang RM; Morgan T; Bellman GC
    J Endourol; 2002 Dec; 16(10):727-31. PubMed ID: 12542875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recommendations for occupational radiation protection in interventional cardiology.
    Durán A; Hian SK; Miller DL; Le Heron J; Padovani R; Vano E
    Catheter Cardiovasc Interv; 2013 Jul; 82(1):29-42. PubMed ID: 23475846
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation exposure and the urologist: what are the risks?
    Hellawell GO; Mutch SJ; Thevendran G; Wells E; Morgan RJ
    J Urol; 2005 Sep; 174(3):948-52; discussion 952. PubMed ID: 16094003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.