These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

263 related articles for article (PubMed ID: 25832059)

  • 21. Resolution- versus sensitivity-effective diameter in pinhole collimation: experimental verification.
    Metzler SD; Accorsi R
    Phys Med Biol; 2005 Nov; 50(21):5005-17. PubMed ID: 16237237
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A scanning focus nuclear microscope with multi-pinhole collimation.
    Nguyen MP; Arif M; Oostenrijk B; Goorden MC; Beekman FJ
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848684
    [TBL] [Abstract][Full Text] [Related]  

  • 23.
    Esquinas PL; Rodríguez-Rodríguez C; Carlos De La Vega J; Bokharaei M; Saatchi K; Shirmohammad M; Häfeli UO; Sossi V; Celler A
    Phys Med; 2017 Jan; 33():26-37. PubMed ID: 28007432
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An efficient simulator for pinhole imaging of PET isotopes.
    Goorden MC; van der Have F; Kreuger R; Beekman FJ
    Phys Med Biol; 2011 Mar; 56(6):1617-34. PubMed ID: 21335647
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of Improved Imaging Properties with Tungsten-Based Parallel-Hole Collimators: A Monte Carlo Study.
    Pirayesh Islamian J; Ljungberg M
    World J Nucl Med; 2024 Jun; 23(2):95-102. PubMed ID: 38933066
    [No Abstract]   [Full Text] [Related]  

  • 26. Monte Carlo simulations of pinhole imaging accelerated by kernel-based forced detection.
    Gieles M; de Jong HW; Beekman FJ
    Phys Med Biol; 2002 Jun; 47(11):1853-67. PubMed ID: 12108771
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optimizing multi-pinhole SPECT geometries using an analytical model.
    Rentmeester MC; van der Have F; Beekman FJ
    Phys Med Biol; 2007 May; 52(9):2567-81. PubMed ID: 17440253
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Mammotomography with pinhole incomplete circular orbit SPECT.
    Tornai MP; Bowsher JE; Jaszczak RJ; Pieper BC; Greer KL; Hardenbergh PH; Coleman RE
    J Nucl Med; 2003 Apr; 44(4):583-93. PubMed ID: 12679403
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design of a Tri-PET collimator for high-resolution whole-body mouse imaging.
    DiFilippo FP
    Med Phys; 2017 Aug; 44(8):4230-4238. PubMed ID: 28556264
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A Monte Carlo Simulation Study of Optimization for Collimator in a Pixelated SPECT Camera.
    Telikani Z; Sadremomtaz A
    J Med Imaging Radiat Sci; 2019 Mar; 50(1):163-170. PubMed ID: 30777239
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Quantitative imaging of iodine-131 distributions in brain tumors with pinhole SPECT: a phantom study.
    Smith MF; Gilland DR; Coleman RE; Jaszczak RJ
    J Nucl Med; 1998 May; 39(5):856-64. PubMed ID: 9591589
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector.
    Ogawa K; Ohmura N; Iida H; Nakamura K; Nakahara T; Kubo A
    Ann Nucl Med; 2009 Oct; 23(8):763-70. PubMed ID: 19680739
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of Wolfmet Tungsten Alloys as Parallel-Hole Collimator Material on Single-Photon Emission Computed Tomography Image Quality and Functional Parameters: A Simulating Medical Imaging Nuclear Detectors Monte Carlo Study.
    Darami M; Mahmoudian B; Ljungberg M; Pirayesh Islamian J
    World J Nucl Med; 2023 Sep; 22(3):217-225. PubMed ID: 37854088
    [No Abstract]   [Full Text] [Related]  

  • 34. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.
    Van Audenhaege K; Van Holen R; Vandenberghe S; Vanhove C; Metzler SD; Moore SC
    Med Phys; 2015 Aug; 42(8):4796-813. PubMed ID: 26233207
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Efficient Monte-Carlo based system modelling for image reconstruction in preclinical pinhole SPECT.
    Nguyen MP; Goorden MC; Ramakers RM; Beekman FJ
    Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34049291
    [TBL] [Abstract][Full Text] [Related]  

  • 36. On-axis sensitivity and resolution of a slit-slat collimator.
    Metzler SD; Accorsi R; Novak JR; Ayan AS; Jaszczak RJ
    J Nucl Med; 2006 Nov; 47(11):1884-90. PubMed ID: 17079823
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of pinhole shape on projection resolution.
    Johnson LC; Moore SC; Metzler SD
    Phys Med Biol; 2016 Mar; 61(5):2003-13. PubMed ID: 26894917
    [TBL] [Abstract][Full Text] [Related]  

  • 38. ALBIRA: a small animal PET∕SPECT∕CT imaging system.
    Sánchez F; Orero A; Soriano A; Correcher C; Conde P; González A; Hernández L; Moliner L; Rodríguez-Alvarez MJ; Vidal LF; Benlloch JM; Chapman SE; Leevy WM
    Med Phys; 2013 May; 40(5):051906. PubMed ID: 23635276
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study.
    Zeraatkar N; Farahani MH; Rahmim A; Sarkar S; Ay MR
    Med Phys; 2016 May; 43(5):2581. PubMed ID: 27147368
    [TBL] [Abstract][Full Text] [Related]  

  • 40. SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.
    Van Holen R; Staelens S; Vandenberghe S
    Med Phys; 2009 Sep; 36(9):4257-67. PubMed ID: 19810500
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.