These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Model based analysis of piezoelectric transformers. Hemsel T; Priya S Ultrasonics; 2006 Dec; 44 Suppl 1():e741-5. PubMed ID: 16808951 [TBL] [Abstract][Full Text] [Related]
4. Research on methods to increase the flashover voltage of supporting insulators in Tesla transformers. Li J; Shi H; Wang Y; Ge J; Wu F; Huang Q; Zhang Y; Li Q Rev Sci Instrum; 2024 Jul; 95(7):. PubMed ID: 38995154 [TBL] [Abstract][Full Text] [Related]
5. Analysis of a modular generator for high-voltage, high-frequency pulsed applications, using low voltage semiconductors (< 1 kV) and series connected step-up (1:10) transformers. Redondo LM; Fernando Silva J; Margato E Rev Sci Instrum; 2007 Mar; 78(3):034702. PubMed ID: 17411205 [TBL] [Abstract][Full Text] [Related]
6. Development of 600 kV triple resonance pulse transformer. Li M; Zhang F; Liang C; Xu Z Rev Sci Instrum; 2015 Jun; 86(6):064707. PubMed ID: 26133858 [TBL] [Abstract][Full Text] [Related]
7. Fast switching thyristor applied in nanosecond-pulse high-voltage generator with closed transformer core. Li L; Bao C; Feng X; Liu Y; Fochan L Rev Sci Instrum; 2013 Feb; 84(2):024703. PubMed ID: 23464234 [TBL] [Abstract][Full Text] [Related]
8. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines. Homma A Rev Sci Instrum; 2011 Jul; 82(7):074701. PubMed ID: 21806208 [TBL] [Abstract][Full Text] [Related]
9. Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings. Srikanta Murthy A; Azis N; Jasni J; Othman ML; Mohd Yousof MF; Talib MA PLoS One; 2020; 15(10):e0240368. PubMed ID: 33035254 [TBL] [Abstract][Full Text] [Related]
10. New equivalent lumped electrical circuit for piezoelectric transformers. Gonnard P; Schmitt PM; Brissaud M IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Apr; 53(4):802-9. PubMed ID: 16615585 [TBL] [Abstract][Full Text] [Related]
11. Electrical and mechanical fully coupled theory and experimental verification of Rosen-type piezoelectric transformers. Hsu YH; Lee CK; Hsiao WH IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Oct; 52(10):1829-39. PubMed ID: 16382636 [TBL] [Abstract][Full Text] [Related]
12. A 70 kV solid-state high voltage pulse generator based on saturable pulse transformer. Fan X; Liu J Rev Sci Instrum; 2014 Feb; 85(2):024708. PubMed ID: 24593384 [TBL] [Abstract][Full Text] [Related]
13. Power enhancement of piezoelectric transformers by adding heat transfer equipment. Su YH; Liu YP; Vasic D; Wu WJ; Costa F; Lee CK IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Oct; 59(10):2129-36. PubMed ID: 23143563 [TBL] [Abstract][Full Text] [Related]
14. The investigation of a compact auto-connected wire-wrapped pulsed transformer. Wang Y; Zhang J; Chen D; Cao S; Li D; Zhang T Rev Sci Instrum; 2012 May; 83(5):054702. PubMed ID: 22667636 [TBL] [Abstract][Full Text] [Related]
15. Analysis, design, and control of a transcutaneous power regulator for artificial hearts. Qianhong Chen ; Siu Chung Wong ; Tse CK; Xinbo Ruan IEEE Trans Biomed Circuits Syst; 2009 Feb; 3(1):23-31. PubMed ID: 23853160 [TBL] [Abstract][Full Text] [Related]
16. High power universal piezoelectric transformer. Priya S; Kim H; Ural S; Uchino K IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Apr; 53(4):810-6. PubMed ID: 16615586 [TBL] [Abstract][Full Text] [Related]
17. Transformation of Transient Overvoltages by Inductive Voltage Transformers. Kaczmarek M; Brodecki D Sensors (Basel); 2021 Jun; 21(12):. PubMed ID: 34204540 [TBL] [Abstract][Full Text] [Related]
18. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line. Zhou Q; He W; Xiao D; Li S; Zhou K Sensors (Basel); 2015 Dec; 16(1):. PubMed ID: 26729119 [TBL] [Abstract][Full Text] [Related]
19. Ceramic-Heterostructure-Based Magnetoelectric Voltage Transformer with an Adjustable Transformation Ratio. Saveliev D; Chashin D; Fetisov L; Shamonin M; Fetisov Y Materials (Basel); 2020 Sep; 13(18):. PubMed ID: 32916785 [TBL] [Abstract][Full Text] [Related]
20. Paul Drude's prediction of nonreciprocal mutual inductance for Tesla transformers. McGuyer B PLoS One; 2014; 9(12):e115397. PubMed ID: 25542040 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]