These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 25834002)

  • 1. Wear of the Charité® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator.
    Moghadas P; Mahomed A; Shepherd DE; Hukins DW
    Proc Inst Mech Eng H; 2015 Mar; 229(3):264-8. PubMed ID: 25834002
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of the loading frequency on the wear rate of a polyethylene-on-metal lumbar intervertebral disc replacement.
    Kettler A; Bushelow M; Wilke HJ
    Eur Spine J; 2012 Jun; 21 Suppl 5(Suppl 5):S709-16. PubMed ID: 20936310
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wear in metal-on-metal total disc arthroplasty.
    Moghadas P; Mahomed A; Hukins DW; Shepherd DE
    Proc Inst Mech Eng H; 2013 Apr; 227(4):356-61. PubMed ID: 23637211
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement.
    Vicars R; Prokopovich P; Brown TD; Tipper JL; Ingham E; Fisher J; Hall RM
    Spine (Phila Pa 1976); 2012 Apr; 37(9):E528-34. PubMed ID: 22037530
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dynamic, six-axis stiffness matrix characteristics of the intact intervertebral disc and a disc replacement.
    Holsgrove TP; Gill HS; Miles AW; Gheduzzi S
    Proc Inst Mech Eng H; 2015 Nov; 229(11):769-77. PubMed ID: 26503838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An investigation into PEEK-on-PEEK as a bearing surface candidate for cervical total disc replacement.
    Kraft M; Koch DK; Bushelow M
    Spine J; 2012 Jul; 12(7):603-11. PubMed ID: 22964013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polymer-on-metal or metal-on-polymer total disc arthroplasty: does it make a difference?
    Moghadas PM; Shepherd DE; Hukins DW; Mahomed A
    Spine (Phila Pa 1976); 2012 Oct; 37(21):1834-8. PubMed ID: 22498992
    [TBL] [Abstract][Full Text] [Related]  

  • 8. UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.
    Veruva SY; Lanman TH; Isaza JE; MacDonald DW; Kurtz SM; Steinbeck MJ
    Clin Orthop Relat Res; 2015 Mar; 473(3):987-98. PubMed ID: 25367112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a clinically relevant impingement test method for a mobile bearing lumbar total disc replacement.
    Siskey R; Peck J; Mehta H; Kosydar A; Kurtz S; Hill G
    Spine J; 2016 Sep; 16(9):1133-42. PubMed ID: 27179625
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement.
    Affatato S; Cristofolini L; Leardini W; Erani P; Zavalloni M; Tigani D; Viceconti M
    Artif Organs; 2008 Dec; 32(12):942-8. PubMed ID: 19133022
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatial variation of wear on Charité lumbar discs.
    Prokopovich P; Perni S; Fisher J; Hall RM
    Acta Biomater; 2011 Nov; 7(11):3914-26. PubMed ID: 21745608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A hip wear simulator for the evaluation of biomaterials in hip arthroplasty components.
    Mejia LC; Brierley TJ
    Biomed Mater Eng; 1994; 4(4):259-71. PubMed ID: 7950874
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear assessments of a new cervical spinal disk prosthesis: Influence of loading and kinematic patterns during in vitro wear simulation.
    Wu W; Lyu J; Liu H; Rong X; Wang B; Hong Y; Gong Q; Li T; Liu L; Song Y; Cai Y; Xu W
    Proc Inst Mech Eng H; 2015 Sep; 229(9):619-28. PubMed ID: 26163521
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preferential superior surface motion in wear simulations of the Charité total disc replacement.
    Goreham-Voss CM; Vicars R; Hall RM; Brown TD
    Eur Spine J; 2012 Jun; 21 Suppl 5(Suppl 5):S700-8. PubMed ID: 20582556
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measures for reducing ultra-high-molecular-weight polyethylene wear in total knee replacement: a simulator study.
    Mueller-Rath R; Kleffner B; Andereya S; Mumme T; Wirtz DC
    Biomed Tech (Berl); 2007 Aug; 52(4):295-300. PubMed ID: 17691863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of impingement behaviour in lumbar spinal disc arthroplasty.
    Grupp TM; Yue JJ; Garcia R; Kaddick C; Fritz B; Schilling C; Schwiesau J; Blömer W
    Eur Spine J; 2015 Sep; 24(9):2033-46. PubMed ID: 24903396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Disc arthroplasty design influences intervertebral kinematics and facet forces.
    Rousseau MA; Bradford DS; Bertagnoli R; Hu SS; Lotz JC
    Spine J; 2006; 6(3):258-66. PubMed ID: 16651219
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo functional performance of failed Prodisc-L devices: retrieval analysis of lumbar total disc replacements.
    Lebl DR; Cammisa FP; Girardi FP; Wright T; Abjornson C
    Spine (Phila Pa 1976); 2012 Sep; 37(19):E1209-17. PubMed ID: 22531474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.
    Grupp TM; Yue JJ; Garcia R; Basson J; Schwiesau J; Fritz B; Blömer W
    Eur Spine J; 2009 Jan; 18(1):98-108. PubMed ID: 19050942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Alternative bearing materials for intervertebral disc arthroplasty.
    Grupp TM; Meisel HJ; Cotton JA; Schwiesau J; Fritz B; Blömer W; Jansson V
    Biomaterials; 2010 Jan; 31(3):523-31. PubMed ID: 19815271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.