  • 1. The use of infrared thermography as a rapid, quantitative, and noninvasive method for evaluation of inflammation response in different anatomical regions of rats.
    Całkosiński I; Dobrzyński M; Rosińczuk J; Dudek K; Chrószcz A; Fita K; Dymarek R
    Biomed Res Int; 2015; 2015():972535. PubMed ID: 25834830
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Specific thermographic changes during Walker 256 carcinoma development: differential infrared imaging of tumour, inflammation and haematoma.
    Poljak-Blazi M; Kolaric D; Jaganjac M; Zarkovic K; Skala K; Zarkovic N
    Cancer Detect Prev; 2009; 32(5-6):431-6. PubMed ID: 19232842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Infrared thermography in children: a reliable tool for differential diagnosis of peripheral microvascular dysfunction and Raynaud's phenomenon?
    Martini G; Cappella M; Culpo R; Vittadello F; Sprocati M; Zulian F
    Pediatr Rheumatol Online J; 2019 Oct; 17(1):68. PubMed ID: 31619252
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Thermometry in experimental inflammation. II. Studies of the effect of local cold application on the skin temperature of the rat's paw in experimental inflammation].
    Kessler F; Schmidt KL
    Z Rheumatol; 1984; 43(2):83-8. PubMed ID: 6203256
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is It Possible to Detect Activated Brown Adipose Tissue in Humans Using Single-Time-Point Infrared Thermography under Thermoneutral Conditions? Impact of BMI and Subcutaneous Adipose Tissue Thickness.
    Gatidis S; Schmidt H; Pfannenberg CA; Nikolaou K; Schick F; Schwenzer NF
    PLoS One; 2016; 11(3):e0151152. PubMed ID: 26967519
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Statistical Study on Human Temperature Measurement by Infrared Thermography.
    Švantner M; Lang V; Skála J; Kohlschütter T; Honner M; Muzika L; Kosová E
    Sensors (Basel); 2022 Nov; 22(21):. PubMed ID: 36366093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Infrared thermography: a rapid, portable, and accurate technique to detect experimental pneumothorax.
    Rich PB; Dulabon GR; Douillet CD; Listwa TM; Robinson WP; Zarzaur BL; Pearlstein R; Katz LM
    J Surg Res; 2004 Aug; 120(2):163-70. PubMed ID: 15234209
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Infrared Thermographic Analysis of Surface Temperature of the Hands During Exposure to Normobaric Hypoxia.
    Jones D; Covins SF; Miller GE; Morrison KI; Clark AG; Calcott SD; Anderson AM; Lucas SJE; Imray CHE
    High Alt Med Biol; 2018 Dec; 19(4):388-393. PubMed ID: 30132730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Skin temperature assessment for neuromusculoskeletal abnormalities of the spinal column.
    Plaugher G
    J Manipulative Physiol Ther; 1992; 15(6):365-81. PubMed ID: 1431620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of inflammation in man and animals by radiometry.
    Collins AJ; Ring EF
    Br J Pharmacol; 1972 Jan; 44(1):145-52. PubMed ID: 5015034
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time infrared thermography detection of magnetic nanoparticle hyperthermia in a murine model under a non-uniform field configuration.
    Rodrigues HF; Mello FM; Branquinho LC; Zufelato N; Silveira-Lacerda EP; Bakuzis AF
    Int J Hyperthermia; 2013 Dec; 29(8):752-67. PubMed ID: 24138472
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Infrared Skin Thermometry: Validating and Comparing Techniques to Detect Periwound Skin Infection.
    Mufti A; Somayaji R; Coutts P; Sibbald RG
    Adv Skin Wound Care; 2018 Jan; 31(1):607-611. PubMed ID: 29240589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Infantile hemangioma status by dynamic infrared thermography: A preliminary study.
    Burkes SA; Patel M; Adams DM; Hammill AM; Eaton KP; Randall Wickett R; Visscher MO
    Int J Dermatol; 2016 Oct; 55(10):e522-32. PubMed ID: 27062495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The application of infrared thermography in evaluation of patients at high risk for lower extremity peripheral arterial disease.
    Huang CL; Wu YW; Hwang CL; Jong YS; Chao CL; Chen WJ; Wu YT; Yang WS
    J Vasc Surg; 2011 Oct; 54(4):1074-80. PubMed ID: 21784604
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Screening of febrile cows using a small handheld infrared thermography device].
    Bleul U; Hässig M; Kluser F
    Tierarztl Prax Ausg G Grosstiere Nutztiere; 2021 Feb; 49(1):12-20. PubMed ID: 33588477
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Distal infrared thermography and skin temperature after ultrasound-guided interscalene brachial plexus block: a prospective observational study.
    Asghar S; Bjerregaard LS; Lundstrøm LH; Lund J; Jenstrup MT; Lange KH
    Eur J Anaesthesiol; 2014 Nov; 31(11):626-34. PubMed ID: 25232864
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermographic imaging of postoperative inflammation modified by anti-inflammatory pretreatment.
    Ventä I; Hyrkäs T; Paakkari I; Ylipaavalniemi P
    J Oral Maxillofac Surg; 2001 Feb; 59(2):145-8; discussion 149-50. PubMed ID: 11213982
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infrared thermographic imaging in the assessment of successful block on lumbar sympathetic ganglion.
    Kim YC; Bahk JH; Lee SC; Lee YW
    Yonsei Med J; 2003 Feb; 44(1):119-24. PubMed ID: 12619184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Infrared methodologies for the assessment of skin temperature daily rhythm in two domestic mammalian species.
    Giannetto C; Arfuso F; Giudice E; Gianesella M; Fazio F; Panzera M; Piccione G
    J Therm Biol; 2020 Aug; 92():102677. PubMed ID: 32888574
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of infrared thermography and laser speckle contrast imaging for the dynamic assessment of digital microvascular function.
    Pauling JD; Shipley JA; Raper S; Watson ML; Ward SG; Harris ND; McHugh NJ
    Microvasc Res; 2012 Mar; 83(2):162-7. PubMed ID: 21763703
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]